Instantaneous active and reactive current control technique of shunt active power filter based on the three-level NPC inverter

被引:29
作者
Pouresmaeil, Edris [1 ]
Montesinos-Miracle, Daniel [1 ,2 ]
Gomis-Bellmunt, Oriol [1 ,2 ]
Sudria-Andreu, Antoni [1 ,2 ]
机构
[1] Univ Politecn Cataluna, Dept Engn Elect, Ctr Innovacio Tecnol Convertidores Estat & Accion, ETS Engn Ind Barcelona, E-08028 Barcelona, Spain
[2] Catalonia Inst Energy Res IREC, Barcelona, Spain
来源
EUROPEAN TRANSACTIONS ON ELECTRICAL POWER | 2011年 / 21卷 / 07期
关键词
neutral-point-clamped (NPC) converter; shunt active power filter (SAPF); total harmonic distortion (THD); distributed generation (DG); space vector PWM (SVPWM); voltage source inverter (VSI); VOLTAGE-SOURCE; DESIGN;
D O I
10.1002/etep.536
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, the synthesis and performance of a shunt active power filter (SAPF) based on instantaneous active, and reactive current components (i(d)-i(q)) technique is presented. The proposed active filter acts as a current source, which is connected in parallel with a nonlinear load and controlled to generate the required compensation currents. The proposed control technique for SAPF aims to compensate the harmonic current contents of nonlinear loads by connection of distributed generation (DG) resources based on renewable energy sources to distribution network. This modeling is derived from the 123(abc) to alpha beta and alpha beta to dq transformation of the ac system variables. The injected currents by the SAPF to polluted grid are controlled in synchronous orthogonal dq reference frame by using of decoupled current control technique. By use of phase locked loop (PLL) in control circuit of proposed technique, the angle of positive sequence has been detected, in order to synchronize the SAPF injected currents to distribution network. The proposed control strategy has this ability to eliminate wide range of harmonic frequency draws from utility grid, and provide the compensation currents by DG resources. By this control method, replacement of distributed power generation systems as an active power filter can be possible. Three-phase three-level neutral-point-clamped (NPC) voltage source inverter (VSI) is proposed for the interfacing between renewable energy resources and polluted distribution network. The simulation results demonstrate high performances of proposed SAPF technique. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:2007 / 2022
页数:16
相关论文
共 26 条
[1]  
Aburto V, 1997, IEEE POWER ELECTRON, P1121, DOI 10.1109/PESC.1997.616889
[2]   ANALYSIS AND DESIGN OF AN ACTIVE POWER FILTER USING QUAD-SERIES VOLTAGE SOURCE PWM CONVERTERS [J].
AKAGI, H ;
TSUKAMOTO, Y ;
NABAE, A .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1990, 26 (01) :93-98
[3]  
Akagi H, 2007, INSTANTANEOUS POWER
[4]  
Asiminoaei L, 2005, APPL POWER ELECT CO, P635
[5]   Overview of control and grid synchronization for distributed power generation systems [J].
Blaabjerg, Frede ;
Teodorescu, Remus ;
Liserre, Marco ;
Timbus, Adrian V. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (05) :1398-1409
[6]  
Clarke E., 1943, CIRCUIT ANAL A C POW, V1
[7]   THE FBD-METHOD, A GENERALLY APPLICABLE TOOL FOR ANALYZING POWER RELATIONS [J].
DEPENBROCK, M .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1993, 8 (02) :381-387
[8]   Three-phase active power filter based on current controlled voltage source inverter [J].
El-Kholy, E. E. ;
El-Sabbe, A. ;
Ei-Hefnawy, A. ;
Mharous, Hamdy M. .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2006, 28 (08) :537-547
[9]   Ride-Through Control of a Doubly Fed Induction Generator Under Unbalanced Voltage Sags [J].
Gomis-Bellmunt, Oriol ;
Junyent-Ferre, Adria ;
Sumper, Andreas ;
Bergas-Jane, Joan .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2008, 23 (04) :1036-1045
[10]  
HOLTZ J, 1992, IEEE TIE, V39