Dose distribution from x-ray microbeam arrays applied to radiation therapy: An EGS4 Monte Carlo study

被引:45
作者
De Felici, M
Felici, R
del Rio, MS
Ferrero, C
Bacarian, T
Dilmanian, FA
机构
[1] INFM, OGG, ESRF, F-38043 Grenoble, France
[2] European Synchrotron Radiat Facil, F-38043 Grenoble, France
[3] Brookhaven Natl Lab, Dept Med, Upton, NY 11973 USA
关键词
Monte Carlo simulation; photon-electron transport; EGS4; x-ray microdosimetry; microbeam radiation therapy;
D O I
10.1118/1.1951043
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We present EGS4 Monte Carlo calculations of the spatial distribution of the dose deposited by a single x-ray pencil beam, a planar microbeam, and an array of parallel planar microbeams as used in radiation therapy research. The profiles of the absorbed dose distribution in a phantom, including the peak-to-valley ratio of the dose distribution from microbeam arrays, were calculated. at micrometer resolution. We determined the dependence of the findings on the main parameters of photon and electron transport. The results illustrate the dependence of the electron range and the deposited in-beam dose on the cut-off energy, of the electron transport, as well as the effects on the dose profiles of the beam energy, the array size, and the beam spacing. The effect of beam polarization also was studied for a single pencil beam and for an array of parallel planar microbeams. The results show that although the polarization effect on the dose distribution from a 3 cm X 3 cm microbeam array inside a water phantom is large enough to be measured at the outer side of the array (16% difference of the deposited dose for x-ray beams of 200 keV), it is not detectable at the array's center, thus being irrelevant for the radiation therapy purposes. Finally we show that to properly compare the dose profiles determined with a metal oxide semiconductor field emission transistor detector with the computational method predictions, it is important to simulate adequately the size and the material of the device's Si active element. (c) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:2455 / 2463
页数:9
相关论文
共 50 条
  • [1] X-ray microbeam radiation therapy calculations, including polarisation effects, with the Monte Carlo code EGS5
    Hugtenburg, Richard P.
    Adegunloye, A. S.
    Bradley, David A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 619 (1-3) : 221 - 224
  • [2] Monte Carlo dose enhancement studies in microbeam radiation therapy
    Martinez-Rovira, I.
    Prezado, Y.
    MEDICAL PHYSICS, 2011, 38 (07) : 4430 - 4439
  • [3] CALCULATION OF BETA DOSIMETRY IN RADIATION SYNOVECTOMY USING MONTE-CARLO SIMULATION (EGS4)
    JOHNSON, LS
    YANCH, JC
    MEDICAL PHYSICS, 1993, 20 (03) : 747 - 754
  • [4] Technical advances in x-ray microbeam radiation therapy
    Bartzsch, Stefan
    Corde, Stephanie
    Crosbie, Jeffrey C.
    Day, Liam
    Donzelli, Mattia
    Krisch, Michael
    Lerch, Michael
    Pellicioli, Paolo
    Smyth, Lloyd M. L.
    Tehei, Moeava
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (02)
  • [5] Surface dose reduction from bone interface in kilovoltage X-ray radiation therapy: a Monte Carlo study of photon spectra
    Chow, James C. L.
    Owrangi, Amir M.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (05): : 215 - 222
  • [6] A comparison between EGS4 and MCNP computer modeling of an in vivo X-ray fluorescence system
    Al-Ghorabie, FHH
    Natto, SSA
    Al-Lyhiani, SHA
    COMPUTERS IN BIOLOGY AND MEDICINE, 2001, 31 (02) : 73 - 83
  • [7] DOSE3D: EGS4 Monte Carlo code-based software for internal radionuclide dosimetry
    Clairand, I
    Ricard, M
    Gouriou, J
    Di Paola, M
    Aubert, B
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (09) : 1517 - 1523
  • [8] Benchmarking and validation of a Geant4-SHADOW Monte Carlo simulation for dose calculations in microbeam radiation therapy
    Cornelius, Iwan
    Guatelli, Susanna
    Fournier, Pauline
    Crosbie, Jeffrey C.
    del Rio, Manuel Sanchez
    Braeuer-Krisch, Elke
    Rosenfeld, Anatoly
    Lerch, Michael
    JOURNAL OF SYNCHROTRON RADIATION, 2014, 21 : 518 - 528
  • [9] Experimental optimisation of the X-ray energy in microbeam radiation therapy
    Livingstone, Jayde
    Stevenson, Andrew W.
    Hausermann, Daniel
    Adam, Jean-Francois
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 45 : 156 - 161
  • [10] Brain motion induced artefacts in Microbeam Radiation Therapy: a Monte Carlo study
    Donzelli, M.
    Brauer-Krisch, E.
    Oelfke, U.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S34 - S35