Liquid chromatography-tandem mass spectrometry direct injection analysis of organophosphorus flame retardants in Ontario surface water and wastewater effluent

被引:73
|
作者
Hao, Chunyan [1 ]
Helm, Paul A. [2 ]
Morse, David [1 ]
Reiner, Eric J. [1 ]
机构
[1] Ontario Minist Environm & Climate Change, Lab Serv Branch, 125 Resources Rd, Etobicoke, ON M9P 3V6, Canada
[2] Ontario Minist Environm & Climate Change, Environm Monitoring & Reporting Branch, 125 Resources Rd, Etobicoke, ON M9P 3V6, Canada
关键词
Organophosphorus flame retardants (OPFRs); Direct injection analysis (DIA); Liquid chromatography-tandem mass spectrometry (LC-MS/MS); Water analysis; SOLID-PHASE EXTRACTION; GAS-CHROMATOGRAPHY; PHTHALATE-ESTERS; GROUND-WATER; HOUSE-DUST; INDOOR AIR; PLASTICIZERS; PHOSPHATE; EXPOSURE; SAMPLES;
D O I
10.1016/j.chemosphere.2017.10.060
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Organophosphorus flame retardants (OPFRs) started to be used in plastics, electronics and furnishings back in the 1960s and became popular again last decade. They are now widely present in the environment and regarded as "new" emerging organic pollutants. An effective liquid chromatography-tandem mass spectrometry (LC-MS/MS) direct injection analysis (DIA) method was developed to monitor OPFR levels in aquatic environment. The removal of sample extraction and concentration steps not only improved operation efficiency, but also reduced the potential contamination commonly observed during the sample preparation process before. Positive background signals from the analytical instrument were eliminated by employing a "trap" column in front of the sample injector while an ACE C18 and an ACE C18-PFP column were compared for the separation of OPFR5. Nineteen OPFR related compounds were evaluated and rapid signal drops were observed for seven of them including TOTP, TMTP, TPTP, TEHP, T35DMPP, T2iPPP and EHDP, due to their low water solubility. The other twelve compounds, TMP, TEP, TPrP, TiPP, TBP, TCEP, TCPP, TDCPP, TPP, TBEP, BDCP and BEHP, were included for the measurement of OPFRs in drinking water, surface water, ground water and wastewater effluent samples. The instrumental detection limits of these twelve OPFRs at signal-to-noise >= 3 were in the 1.5-30 ng/L range. The method was applied for the determination of OPFRs in surface water and wastewater samples in Ontario, Canada, and BEHP, TBEP, TBP, TCEP, TCPP, TDCPP, and TEP were commonly detected. Crown Copyright (C) 2017 Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:288 / 295
页数:8
相关论文
共 50 条
  • [11] Determination of Organophosphorus Flame Retardants in Surface Water by Solid Phase Extraction Coupled with Gas Chromatography-Mass Spectrometry
    Yan Xiao-Ju
    He Huan
    Peng Ying
    Wang Xiao-Meng
    Gao Zhan-Qi
    Yang Shao-Gui
    Sun Cheng
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (11) : 1693 - 1696
  • [12] Quantification of two urinary metabolites of organophosphorus flame retardants by solid-phase extraction and gas chromatography-tandem mass spectrometry
    Schindler, Birgit Karin
    Foerster, Katrin
    Angerer, Juergen
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 395 (04) : 1167 - 1171
  • [13] Determination of organophosphorus flame retardants in textile wastewater by dispersive liquid-liquid microextraction based on solidification of floating organic drop followed by ultra-high performance liquid chromatography-tandem mass spectrometry
    He Jing
    Ye Xiwen
    Tang Zhixu
    Niu Zengyuan
    Luo Xin
    Zou Li
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2020, 38 (06) : 679 - 686
  • [14] Analysis of antithyroid drugs in surface water by using liquid chromatography-tandem mass spectrometry
    Perez-Fernandez, Virginia
    Marchese, Stefano
    Gentili, Alessandra
    Angeles Garcia, Maria
    Curini, Roberta
    Caretti, Fulvia
    Perret, Daniela
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1367 : 78 - 89
  • [15] Development of liquid chromatography atmospheric pressure chemical ionization tandem mass spectrometry for analysis of halogenated flame retardants in wastewater
    Zhou, Simon Ningsun
    Reiner, Eric J.
    Marvin, Chris
    Helm, Paul
    Riddell, Nicole
    Dorman, Frank
    Misselwitz, Michelle
    Shen, Li
    Crozier, Patrick
    MacPherson, Karen
    Brindle, Ian D.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (03) : 1311 - 1320
  • [16] Fast determination of 40 drugs in water using large volume direct injection liquid chromatography-tandem mass spectrometry
    Boix, Clara
    Ibanez, Maria
    Sancho, Juan V.
    Rambla, Javier
    Aranda, Jose L.
    Ballester, Salome
    Hernandez, Felix
    TALANTA, 2015, 131 : 719 - 727
  • [17] Simultaneous Determination of Organophosphate Ester Flame Retardants in Water and Sediments by Gas Chromatography-Tandem Mass Spectrometry (GC-MS/MS)
    Zeng, Yimei
    Ke, Changliang
    Liu, Qi
    Huang, Ke
    ANALYTICAL LETTERS, 2022, 55 (18) : 2928 - 2943
  • [18] Determination of Polybrominated Diphenyl Ether Flame Retardants in Surface Water by Liquid Chromatography-Atmospheric Pressure Photoionization Tandem Mass Spectrometry
    Moukas, Athanasios I.
    Maragou, Niki C.
    Thomaidis, Nikolaos S.
    Calokerinos, Antonios C.
    ANALYTICAL LETTERS, 2018, 51 (1-2) : 96 - 110
  • [19] Determination of polychlorinated hydrocarbons and organophosphorus flame retardants in soil by accelerated solvent extraction combined with gas chromatography-tandem mass spectrometry
    Xu, Yingzao
    Chen, Zhifeng
    Qi, Zenghua
    Cai, Zongwei
    Chinese Journal of Analysis Laboratory, 2022, 41 (06) : 628 - 634
  • [20] Simultaneous liquid chromatography-tandem mass spectrometry analysis of brominated flame retardants (tetrabromobisphenol A and hexabromocyclododecane diastereoisomers) in French breast milk
    Inthavong, Chanthadary
    Hommet, Frederic
    Bordet, Francois
    Rigourd, Virginie
    Guerin, Thierry
    Dragacci, Sylviane
    CHEMOSPHERE, 2017, 186 : 762 - 769