Development and characterization of a dynamic lesion phantom for the quantitative evaluation of dynamic contrast-enhanced MRI

被引:11
|
作者
Freed, Melanie [1 ,2 ]
de Zwart, Jacco A. [3 ]
Hariharan, Prasanna [4 ]
Myers, Matthew R. [4 ]
Badano, Aldo [1 ]
机构
[1] US FDA, Div Imaging & Appl Math, Off Sci & Engn Labs, Ctr Devices & Radiol Hlth, Silver Spring, MD 20993 USA
[2] Univ Maryland, Dept Bioengn, College Pk, MD 20742 USA
[3] Natl Inst Neurol Disorders & Stroke, Lab Funct & Mol Imaging, Adv MRI Sect, NIH, Bethesda, MD 20892 USA
[4] US FDA, Div Solid & Fluid Mech, Off Sci & Engn Labs, Ctr Devices & Radiol Hlth, Silver Spring, MD 20993 USA
关键词
dynamic phantom; DCE-MRI; breast imaging; SPOILED GRADIENT-ECHO; MYOCARDIAL-PERFUSION; DIAGNOSTIC-ACCURACY; BREAST MRI; PARAMETERS; SEQUENCES; RESONANCE; DTPA; STANDARDIZATION; QUANTIFICATION;
D O I
10.1118/1.3633911
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a dynamic lesion phantom that is capable of producing physiological kinetic curves representative of those seen in human dynamic contrast-enhanced MRI (DCE-MRI) data. The objective of this phantom is to provide a platform for the quantitative comparison of DCE-MRI protocols to aid in the standardization and optimization of breast DCE-MRI. Methods: The dynamic lesion consists of a hollow, plastic mold with inlet and outlet tubes to allow flow of a contrast agent solution through the lesion over time. Border shape of the lesion can be controlled using the lesion mold production method. The configuration of the inlet and outlet tubes was determined using fluid transfer simulations. The total fluid flow rate was determined using x-ray images of the lesion for four different flow rates (0.25, 0.5, 1.0, and 1.5 ml/s) to evaluate the resultant kinetic curve shape and homogeneity of the contrast agent distribution in the dynamic lesion. High spatial and temporal resolution x-ray measurements were used to estimate the true kinetic curve behavior in the dynamic lesion for benign and malignant example curves. DCE-MRI example data were acquired of the dynamic phantom using a clinical protocol. Results: The optimal inlet and outlet tube configuration for the lesion molds was two inlet molds separated by 30 degrees and a single outlet tube directly between the two inlet tubes. X-ray measurements indicated that 1.0 ml/s was an appropriate total fluid flow rate and provided truth for comparison with MRI data of kinetic curves representative of benign and malignant lesions. DCE-MRI data demonstrated the ability of the phantom to produce realistic kinetic curves. Conclusions: The authors have constructed a dynamic lesion phantom, demonstrated its ability to produce physiological kinetic curves, and provided estimations of its true kinetic curve behavior. This lesion phantom provides a tool for the quantitative evaluation of DCE-MRI protocols, which may lead to improved discrimination of breast cancer lesions. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3633911]
引用
收藏
页码:5601 / 5611
页数:11
相关论文
共 50 条
  • [21] Multiparametric Characterization of Response to Anti-angiogenic Therapy Using USPIO Contrast-Enhanced MRI in Combination with Dynamic Contrast-Enhanced MRI
    Kim, Jana
    Kim, Eugene
    Euceda, Leslie R.
    Meyer, Dan E.
    Langseth, Karina
    Bathen, Tone F.
    Moestue, Siver A.
    Huuse, Else Marie
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 47 (06) : 1589 - 1600
  • [22] Quantitative effects of acquisition duration and temporal resolution on the measurement accuracy of prostate dynamic contrast-enhanced MRI data: a phantom study
    Knight, Silvin Paul
    Browne, Jacinta Elizabeth
    Meaney, James Frances Mary
    Fagan, Andrew John
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2017, 30 (05) : 461 - 471
  • [23] Blind Deconvolution in Dynamic Contrast-Enhanced MRI and Ultrasound
    Jirik, Radovan
    Soucek, Karel
    Mezl, Martin
    Bartos, Michal
    Drazanova, Eva
    Drafi, Frantisek
    Grossova, Lucie
    Kratochvila, Jiri
    Macicek, Ondrej
    Nylund, Kim
    Hampl, Ales
    Gilja, Odd Helge
    Taxt, Torfinn
    Starcuk, Zenon, Jr.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 4276 - 4279
  • [24] Dynamic Contrast-Enhanced MRI in the Evaluation of Carotid Space Paraganglioma versus Schwannoma
    Gaddikeri, Santhosh
    Hippe, Daniel S.
    Anzai, Yoshimi
    JOURNAL OF NEUROIMAGING, 2016, 26 (06) : 618 - 625
  • [25] Dynamic Contrast-Enhanced Breast MR Imaging
    Moon, Marianne
    Cornfeld, Daniel
    Weinreb, Jeffrey
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2009, 17 (02) : 351 - +
  • [26] Characterization of Tumor Angiogenesis With Dynamic Contrast-Enhanced MRI and Biodegradable Macromolecular Contrast Agents in Mice
    Feng, Yi
    Jeong, Eun-Kee
    Mohs, Aaron M.
    Emerson, Lyska
    Lu, Zheng-Rong
    MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (06) : 1347 - 1352
  • [27] Textural Kinetics: A Novel Dynamic Contrast-Enhanced (DCE)-MRI Feature for Breast Lesion Classification
    Agner, Shannon C.
    Soman, Salil
    Libfeld, Edward
    McDonald, Margie
    Thomas, Kathleen
    Englander, Sarah
    Rosen, Mark A.
    Chin, Deanna
    Nosher, John
    Madabhushi, Anant
    JOURNAL OF DIGITAL IMAGING, 2011, 24 (03) : 446 - 463
  • [28] Background parenchymal enhancement and its effect on lesion detectability in ultrafast dynamic contrast-enhanced MRI
    Honda, Maya
    Kataoka, Masako
    Iima, Mami
    Miyake, Kanae Kawai
    Ohashi, Akane
    Kishimoto, Ayami Ohno
    Ota, Rie
    Nickel, Marcel Dominik
    Toi, Masakazu
    Togashi, Kaori
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 129
  • [29] Quantitative Myocardial Perfusion with Dynamic Contrast-Enhanced Imaging in MRI and CT: Theoretical Models and Current Implementation
    Pelgrim, G. J.
    Handayani, A.
    Dijkstra, H.
    Prakken, N. H. J.
    Slart, R. H. J. A.
    Oudkerk, M.
    Van Ooijen, P. M. A.
    Vliegenthart, R.
    Sijens, P. E.
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [30] Textural Kinetics: A Novel Dynamic Contrast-Enhanced (DCE)-MRI Feature for Breast Lesion Classification
    Shannon C. Agner
    Salil Soman
    Edward Libfeld
    Margie McDonald
    Kathleen Thomas
    Sarah Englander
    Mark A. Rosen
    Deanna Chin
    John Nosher
    Anant Madabhushi
    Journal of Digital Imaging, 2011, 24 : 446 - 463