Airtraq Laryngoscope Versus the Conventional Macintosh Laryngoscope During Pediatric Intubation Performed by Nurses: A Randomized Crossover Manikin Study With Three Airway Scenarios

被引:5
|
作者
Szarpak, Lukasz [1 ]
Karczewska, Katarzyna [2 ]
Czyzewski, Lukasz [3 ]
Truszewski, Zenon [1 ]
Kurowski, Andrzej [4 ]
机构
[1] Med Univ Warsaw, Dept Emergency Med, Lindleya 4 St, PL-02005 Warsaw, Poland
[2] Mazovian Reg Hosp, Anesthesiol & Intens Care Unit, Radom, Poland
[3] Med Univ Warsaw, Dept Nephrol Nursing, Warsaw, Poland
[4] Cardinal Wyszynski Natl Inst Cardiol, Dept Anesthesiol, Warsaw, Poland
关键词
pediatric; endotracheal intubation; airtraq; macintosh; difficult airway; EMERGENCY CARDIOVASCULAR CARE; HEART-ASSOCIATION GUIDELINES; TRACHEAL INTUBATION; CARDIOPULMONARY-RESUSCITATION; LIFE-SUPPORT; ENDOTRACHEAL INTUBATION; MILLER LARYNGOSCOPE; CHEST COMPRESSION; NOVICE DOCTORS; CARDIAC-ARREST;
D O I
10.1097/PEC.0000000000000741
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives We hypothesized that the Airtraq laryngoscope (Airtraq LLC, Bonita Springs, Fla) is beneficial for intubation of pediatric manikins while performing cardiopulmonary resuscitation (CPR). In the present study, we evaluated the effectiveness of the Macintosh (MAC) laryngoscope (HEINE Optotechnik, Munich, Germany) and Airtraq in 3 simulated CPR scenarios. Methods A randomized crossover simulation trial was designed. Eighty-three nurses intubated the trachea of a PediaSIM CPR training manikin (FCAE HealthCare, Sarasota, Fla) using the MAC and Airtraq in a normal airway scenario, normal airway with chest compression scenario, and difficult airway with chest compression scenario. The participants were directed to perform a maximum of 3 attempts in each scenario. The success rate, time to intubation, Cormack & Lehane grade, dental compression, and the ease of intubation were measured. Results All participants performed successful intubation with the Airtraq in all 3 scenarios. In all scenarios, the success rate was significantly higher and the time to intubation was significantly shorter with the Airtraq than with the MAC. Glottic visualization using the Cormack-Lehane scale was also better when using Airtraq in all scenarios. Conclusions In this manikin study, we found that the Airtraq can be used successfully for the intubation of pediatric manikins with normal and difficult airways by medical staff without previous experience in pediatric intubation. Moreover, intubation can be achieved without interrupting chest compression. The use of the Airtraq compared with the MAC led to faster time to intubation. Nevertheless, we recommend that the performance of the Airtraq and the MAC during CPR should be further evaluated in a clinical setting.
引用
收藏
页码:735 / 739
页数:5
相关论文
共 50 条
  • [41] A Randomized Study of Rigid Video Stylet versus Macintosh Laryngoscope for Double-Lumen Endobronchial Tube Intubation Assistance in Thoracoscopic Pulmonary Surgery
    Gu, Yang
    Zhou, Qing
    Zhou, Huanping
    Liu, Meiyun
    Feng, Di
    Wei, Juan
    Min, Keting
    Zhu, Wanli
    Chen, Yuanli
    Lv, Xin
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (02)
  • [42] Comparison of three types of intubation stylets for tracheal intubation with a McGrath MAC® video laryngoscope by novice intubators in simulated cervical immobilisation: A randomised crossover manikin study
    Kim, Sung-Wook
    Kim, Ji-Hoon
    Kim, Young-Min
    Park, Jung Taek
    Choi, Seung Pill
    HONG KONG JOURNAL OF EMERGENCY MEDICINE, 2018, 25 (01) : 27 - 32
  • [43] Comparative evaluation of glidescope videolaryngosocope and conventional macintosh laryngoscope for nasotracheal intubation in patients undergoing oropharyngeal cancer surgeries: A prospective randomized study
    Kumar, Abhishek
    Gupta, Nishkarsh
    Kumar, Vinod
    Bharti, Sachidanand Jee
    Garg, Rakesh
    Kumar, Rajeev
    Bhatnagar, Sushma
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2021, 37 (04) : 542 - 547
  • [44] Parker Flex-It intubation stylet versus a 90-degree curved stylet during intubation with the McGrath videolaryngoscope performed by novices: a manikin study with 5 airway scenarios
    Reus, Erik
    Grundmann, Ulrich
    Liening, Katrin
    Wrobel, Marc
    JOURNAL OF CLINICAL ANESTHESIA, 2013, 25 (08) : 624 - 628
  • [45] Split Type Postman videolaryngoscope: The newer device versus the standard Macintosh laryngoscope in simulated difficult airway - A new hope for difficult intubation scenarios
    Nisanth, N. S.
    Ali, Qazi E.
    Amir, Syed H.
    INDIAN JOURNAL OF ANAESTHESIA, 2022, 66 (03) : 193 - 199
  • [46] Hands-Off Time for Endotracheal Intubation during CPR Is Not Altered by the Use of the C-MAC Video-Laryngoscope Compared to Conventional Direct Laryngoscopy. A Randomized Crossover Manikin Study
    Schuerner, Philipp
    Grande, Bastian
    Piegeler, Tobias
    Schlaepfer, Martin
    Saager, Leif
    Hutcherson, Matthew T.
    Spahn, Donat R.
    Ruetzler, Kurt
    PLOS ONE, 2016, 11 (05):
  • [47] Comparing the performance of traditional direct laryngoscope with three indirect laryngoscopes: A prospective manikin study in normal and difficult airway scenarios
    Ong, Jiann-Ruey
    Chong, Chee-Fah
    Chen, Chien-Chih
    Wang, Tzong-Luen
    Lin, Chiu-Mei
    Chang, Shi-Chuan
    EMERGENCY MEDICINE AUSTRALASIA, 2011, 23 (05) : 606 - 614
  • [48] A comparison of the McGrath-MAC and Macintosh laryngoscopes for child tracheal intubation during resuscitation by paramedics. A randomized, crossover, manikin study
    Szarpak, Lukasz
    Truszewski, Zenon
    Czyzewski, Lukasz
    Gaszynski, Tomasz
    Rodriguez-Nunez, Antonio
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (08) : 1338 - 1341
  • [49] Comparison of Pentax-AWS Airwayscope, Airtraq and Miller laryngoscope for tracheal intubation by novice doctors during infant cardiopulmonary resuscitation simulation: a randomized crossover trial
    Komasawa, Nobuyasu
    Ueki, Ryusuke
    Yamamoto, Noriyasu
    Nishi, Shin-ichi
    Kaminoh, Yoshiroh
    Tashiro, Chikara
    JOURNAL OF ANESTHESIA, 2013, 27 (05) : 778 - 780
  • [50] Comparison of Pentax-AWS Airwayscope, Airtraq and Miller laryngoscope for tracheal intubation by novice doctors during infant cardiopulmonary resuscitation simulation: a randomized crossover trial
    Nobuyasu Komasawa
    Ryusuke Ueki
    Noriyasu Yamamoto
    Shin-ichi Nishi
    Yoshiroh Kaminoh
    Chikara Tashiro
    Journal of Anesthesia, 2013, 27 : 778 - 780