The statistical relevance and effect of assuming pessimistic default overall thermal transmittance coefficients on dwelling energy performance certification quality in Ireland

被引:20
作者
Ahern, Ciara [1 ]
Norton, Brian [2 ]
Enright, Bernard [3 ]
机构
[1] Dublin Inst Technol, Dublin Energy Lab, Sch Mech & Design, Bolton St, Dublin 1, Ireland
[2] Dublin Inst Technol, Dublin Energy Lab, Dublin 7, Ireland
[3] Dublin Inst Technol, Sch Civil & Struct Engn, Bolton St, Dublin 1, Ireland
关键词
Default U-values; Energy performance certification; Irish housing stock; Detached house; CONSUMPTION; BUILDINGS; EFFICIENCY; RETROFITS; STOCK;
D O I
10.1016/j.enbuild.2016.05.089
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the EU, Energy Performance Certificates (EPCs) are issued for dwellings whenever they are constructed, sold or leased. Where requiring data would be prohibitively costly, nationally applicable default-values for the thermal transmittance coefficients of the building envelope are employed. Use of such worst case default U-values ensure that a poor dwelling does not attain a better energy rating than is merited. In the absence of empirical data in Ireland thermal-default U-values, as in many other EU member states, are determined by the type and date of construction and then prevailing building codes. Using 463,582 dwellings representing 32% of the total Irish dwelling stock, this work assesses the relevance of current default U-values. Significant levels of retrofits have been found to lead to the default U-values used now being higher that is typical in reality, thus decreasing the accuracy, and hence credibility, of an EPC. Lack of certification accuracy also inhibits investment in energy efficiency. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:268 / 278
页数:11
相关论文
共 41 条
[1]  
Ahern C., 2016, NATL BER RES TOOL
[2]   State of the Irish housing stock-Modelling the heat losses of Ireland's existing detached rural housing stock 82 estimating the benefit of thermal retrofit measures on this stock [J].
Ahern, Ciara ;
Griffiths, Philip ;
O'Flaherty, Micheal .
ENERGY POLICY, 2013, 55 :139-151
[3]  
Amtmann M., 2010, TABLE REFERENCE BUIL
[4]  
[Anonymous], WILEY SERIES PROBABI
[5]  
[Anonymous], 2012, COMMISSION DELEGATED
[6]  
Arkesteijn K., 2010, ENERGY PERFORMANCE C
[7]  
Badurek M., 2012, TABLE SCI REPORT
[8]   Use of reference buildings to assess the energy saving potentials of the residential building stock: The experience of TABULA project [J].
Ballarini, Ilaria ;
Corgnati, Stefano Paolo ;
Corrado, Vincenzo .
ENERGY POLICY, 2014, 68 :273-284
[9]   Defining the rebound effect [J].
Berkhout, PHG ;
Muskens, JC ;
Velthuijsen, JW .
ENERGY POLICY, 2000, 28 (6-7) :425-432
[10]   Energy retrofits of Danish homes: is the Energy Performance Certificate useful? [J].
Christensen, Toke Haunstrup ;
Gram-Hanssen, Kirsten ;
de Best-Waldhober, Marjolein ;
Adjei, Afi .
BUILDING RESEARCH AND INFORMATION, 2014, 42 (04) :489-500