Preliminary evaluation of Solstice? PF as a replacement carrier solvent for Australian fingermark detection

被引:5
作者
Bouzin, Jemmy T. [1 ,2 ]
Frick, Amanda A. [1 ]
Sauzier, Georgina [1 ]
Lewis, Simon W. [1 ]
机构
[1] Curtin Univ, Sch Mol & Life Sci, GPO Box U1987, Perth, WA 6845, Australia
[2] Seychelles Police Dept, Revolut Ave, Mahe, Seychelles
关键词
Latent fingermarks; Paper substrates; 2-indanedione; Carrier solvents; Supply chain issues; Solstice? PF; LATENT FINGERPRINTS; 1,2-INDANEDIONE; REAGENT;
D O I
10.1016/j.forsciint.2022.111465
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
HFE-710 0 is a routine carrier solvent in amino acid-sensitive fingermark detection reagents such as nin-hydrin and 1,2-indanedione/zinc chloride (IND/Zn). However, a potential EU ban on hydrofluoroethers may require reformulation of these treatments worldwide. Solstice (R) PF has shown promise as a replacement for HFE-710 0 in the United Kingdom. However, the performance (and hence optimal formulation) of IND/Zn is impacted by differences in climate and substrate composition, necessitating assessments under local conditions for different regions. We present a series of preliminary investigations in an Australian context, using the IND/Zn formulation used by Australian forensic service providers. The general performance of Solstice (R) PF-based IND/Zn was comparable to that using HFE-710 0 on three substrate types, three ageing periods (1, 7 and 30 days) and 5 donors. However, slight differences in colour and luminescence intensity, as well as increased ink diffusion, suggest chemical interactions with other reagent components that may affect stability. Specifically, Solstice (R) PF-based reagent formed a precipitate within a month of storage, though this did not affect performance over a 4 month period. HFE-710 0-based IND/Zn was found to be marginally more effective than Solstice (R) PF when applied to incidental fingermarks. These results indicate that Solstice (R) PF is a satisfactory alternative carrier solvent to HFE-710 0 in an Australian context, though users should be aware of possible limitations regarding compatibility with other evidence components (particularly inks) and shelf-life.(c) 2022 Elsevier B.V. All rights reserved.
引用
收藏
页数:11
相关论文
共 32 条
[1]  
Almog J, 2004, J FORENSIC SCI, V49, P981
[2]  
[Anonymous], 2014, Off. J. Eur. Union, VL150, P195
[3]  
[Anonymous], 2017, SOLST PERF FLUID TEC
[4]  
Azoury M, 2002, J FORENSIC SCI, V47, P586
[5]   Use of an optimized 1,2-indanedione process for the development of latent prints [J].
Bicknell, Danna E. ;
Ramotowski, Robert S. .
JOURNAL OF FORENSIC SCIENCES, 2008, 53 (05) :1108-1116
[6]   Visualising the past - An evaluation of processes and sequences for fingermark recovery from old documents [J].
Bleay, S. ;
Fitzgerald, L. ;
Sears, V. ;
Kent, T. .
SCIENCE & JUSTICE, 2019, 59 (02) :125-137
[7]  
Boudreault A., 2017, J FORENSIC IDENTIF, V67, P85
[8]  
Bouzin J.T., 2020, FORENSIC SCI INT REP, V2
[9]   Comparison of three active 1,2-indanedione-zinc formulations for fingermark detection in the context of limited resources and supply chain risks in Seychelles [J].
Bouzin, Jemmy T. ;
Horrocks, Aaron J. ;
Sauzier, Georgina ;
Bleay, Stephen M. ;
Lewis, Simon W. .
FORENSIC CHEMISTRY, 2022, 30
[10]   A study into evaluating the location of fingermarks on letters given activity level propositions [J].
de Ronde, Anouk ;
van Aken, Marja ;
De Poot, Christianne J. ;
de Puit, Marcel .
FORENSIC SCIENCE INTERNATIONAL, 2020, 315