Monte Carlo and water calorimetric determination of kilovoltage beam radiotherapy ionization chamber correction factors

被引:5
作者
Bancheri, Julien [1 ]
Ketelhut, Steffen [2 ]
Buermann, Ludwig [2 ]
Seuntjens, Jan [1 ]
机构
[1] McGill Univ, Med Phys Unit, Cedars Canc Ctr, Montreal, PQ H4A 3J1, Canada
[2] Phys Tech Bundesanstalt PTB, Bundesallee 100, Braunschweig, Germany
基金
加拿大自然科学与工程研究理事会;
关键词
medical physics; kilovoltage dosimetry; reference dosimetry; ionization chambers; correction factors; water calorimetry; radiation primary standard; ENERGY-ABSORPTION COEFFICIENTS; X-RAYS; TRANSPORT; DOSIMETRY; RATIOS; DEPTH;
D O I
10.1088/1361-6560/ab82e7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The in-phantom calibration method for radiotherapy kilovoltage x-ray beams requires ionization chamber correction factors. The overall ionization chamber correction factor accounts for changes in the chamber response due to the displacement of water by the chamber cavity and wall, the presence of the stem and the change in incident photon energy and angular distribution in the phantom to that in air. A waterproof sheath, if required, is accounted for in a sheath correction factor. The aim of this study is to determine chamber correction factors through Monte Carlo (MC) simulations and water calorimetry measurements. Correction factors are determined for the PTW TM30013, NE2571, IBA FC65-G, IBA FC65-P and Exradin A12 ionization chambers. They are compared to experimental values obtained at the German national metrology institute Physikalisch-Technische Bundesanstalt (PTB) with their water calorimetry-based absorbed dose to water primary standard and at other national metrological institutes. An uncertainty analysis considers the contributions to the uncertainty on the chamber correction factors from the field size, photon cross sections, photon fluence spectra and chamber wall and central electrode dimensions. The MC calculated chamber correction factors are within 2.2% of unity with a standard uncertainty of 0.3%. For the 50 kV and 100 - 140 kV radiation beam qualities, the calculated correction factors deviate from the measured correction factors (with a standard uncertainty of 1%) by up to 2.6%. The calculated chamber correction factors for the PTW TM30013 and Exradin A12 are consistent with those derived from the BIPM kilovoltage primary standard. The inconsistencies between the calculated and experimental chamber correction factors indicate the need to further investigate the accuracy of kilovoltage absorbed dose to water primary standards and the use of MC simulations to determine kilovoltage beam chamber correction factors.
引用
收藏
页数:17
相关论文
共 37 条
[1]  
Andreo P, 2018, COMMUNICATION
[2]   Data for the dosimetry of low- and medium-energy kV x rays [J].
Andreo, Pedro .
PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (20)
[3]   On the uncertainties of photon mass energy-absorption coefficients and their ratios for radiation dosimetry [J].
Andreo, Pedro ;
Burns, David T. ;
Salvat, Francesc .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (08) :2117-2136
[4]  
Berger M.J., 2005, ESTAR PSTAR ASTAR CO
[5]  
BUERMANN L, 2016, METROLOGIA S, V53, DOI DOI 10.1088/0026-1394/53/1A/06007
[6]  
BURNS D, 2014, METROLOGIA S, V51, DOI DOI 10.1088/0026-1394/51/1A/06016
[7]   Key comparison BIPM.RI(I)-K9 of the absorbed dose to water standards of the PTB, Germany and the BIPM in medium-energy x-rays [J].
Burns, D. T. ;
Kessler, C. ;
Bueermann, L. ;
Ketelhut, S. .
METROLOGIA, 2018, 55
[8]  
Burns D T, 2017, CCRII1706 FRANC BUR
[9]   The new NMi orthovolt x-rays absorbed dose to water primary standard based on water calorimetry [J].
de Prez, L. A. ;
de Pooter, J. A. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (13) :3531-3542
[10]  
Grimbergen T. W. M., 1997, 10 NCS