When Collateral Supply is Accounted For Epicardial Stenosis Does Not Increase Microvascular Resistance

被引:40
作者
Layland, Jamie [1 ,2 ]
MacIsaac, Andrew I. [1 ,2 ]
Burns, Andrew T. [1 ,2 ]
Somaratne, Jithendra B. [1 ]
Leitl, George [1 ]
Whitbourn, Robert J. [1 ,2 ]
Wilson, Andrew M. [1 ,2 ]
机构
[1] St Vincents Hosp, Dept Cardiol, Melbourne, Vic, Australia
[2] Univ Melbourne, St Vincents Hosp, Dept Med, Melbourne, Vic, Australia
关键词
microcirculation; epicardial stenosis; FFR; PCI; PERCUTANEOUS CORONARY INTERVENTION; FRACTIONAL FLOW RESERVE; EXPERIMENTAL VALIDATION; UNIVERSAL DEFINITION; PHYSIOLOGICAL-BASIS; ARTERY STENOSIS; BLOOD-FLOW; SEVERITY; PRESSURE; ANGIOPLASTY;
D O I
10.1161/CIRCINTERVENTIONS.111.964718
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The relationship between epicardial stenosis and microvascular resistance remains controversial. Exploring the relationship is critical, as many tools used in interventional cardiology imply minimal and constant resistance. However, variable collateralization may impact well on these measures. We hypothesized that when collateral supply was accounted for, microvascular resistance would be independent of epicardial stenosis. Methods and Results-Forty patients with stable angina were studied before and following percutaneous intervention. A temperature and pressure sensing guide wire was used to derive microvascular resistance using the index of microcirculatory resistance (IMR), defined as the hyperemic distal pressure multiplied by the hyperemic mean transit time. Lesion severity was assessed using fractional flow reserve. For comparison, evaluation of an angiographically normal reference vessel from the same subject also was undertaken. Both simple IMR (sIMR) and IMR corrected for collateral flow (cIMR) were calculated. When collateral supply was not accounted for, there was a significant difference in IMR values between the culprit, the post PCI, and nonculprit values (culprit sIMR 26.68 +/- 2.06, nonculprit sIMR 18.37 +/- 1.89, P=0.002; post percutaneous intervention sIMR 18.5 +/- 1.94 versus culprit sIMR 26.68 +/- 2.06, P<0.0001). However, when collateral supply was accounted for there was no difference observed (cIMR 16.96 +/- 1.78 versus nonculprit sIMR 18.37 +/- 1.89, P=0.52; post percutaneous intervention sIMR 18.5 +/- 1.94 versus cIMR 16.96 +/- 1.78, P +/- 0.42). Conclusions-When collateral supply is accounted for, epicardial stenosis does not increase microvascular resistance in patients with stable angina. (Circ Cardiovasc Interv. 2012;5:97-102.)
引用
收藏
页码:97 / 102
页数:6
相关论文
共 24 条
[1]   Epicardial stenosis severity does not affect minimal microcirculatory resistance [J].
Aarnoudse, W ;
Fearon, WF ;
Manoharan, G ;
Geven, M ;
van de Vosse, F ;
Rutten, M ;
De Bruyne, B ;
Pijls, NHJ .
CIRCULATION, 2004, 110 (15) :2137-2142
[2]   Association between coronary lesion severity and distal microvascular resistance in patients with coronary artery disease [J].
Chamuleau, SAJ ;
Siebes, M ;
Meuwissen, M ;
Koch, KT ;
Spaan, JAE ;
Piek, JJ .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2003, 285 (05) :H2194-H2200
[3]   CORONARY MICROVASCULAR RESPONSES TO REDUCTIONS IN PERFUSION-PRESSURE - EVIDENCE FOR PERSISTENT ARTERIOLAR VASOMOTOR TONE DURING CORONARY HYPOPERFUSION [J].
CHILIAN, WM ;
LAYNE, SM .
CIRCULATION RESEARCH, 1990, 66 (05) :1227-1238
[4]   Direct stenting for stable angina pectoris is associated with reduced periprocedural microcirculatory injury compared with stenting after pre-dilation [J].
Cuisset, Thomas ;
Hamilos, Michatis ;
Melikian, Narbeh ;
WyfFels, Eric ;
Sarnia, Jaydeep ;
Sarno, Giovanna ;
Barbato, Emanuele ;
Bartunek, Jozef ;
Wijns, William ;
De Bruyne, Bernard .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (11) :1060-1065
[5]   Coronary thermodilution to assess flow reserve - Experimental validation [J].
De Bruyne, B ;
Pijls, NHJ ;
Smith, L ;
Wievegg, M ;
Heyndrickx, GR .
CIRCULATION, 2001, 104 (17) :2003-2006
[6]   Microvascular resistance is not influenced by epicardial coronary artery stenosis severity - Experimental validation [J].
Fearon, WF ;
Aarnoudse, W ;
Pijls, NHJ ;
De Bruyne, B ;
Balsam, LB ;
Cooke, DT ;
Robbins, RC ;
Fitzgerald, PJ ;
Yeung, AC ;
Yock, PG .
CIRCULATION, 2004, 109 (19) :2269-2272
[7]   Novel index for invasively assessing the coronary microcirculation [J].
Fearon, WF ;
Balsam, LB ;
Farouque, HMO ;
Robbins, RC ;
Fitzgerald, PJ ;
Yock, PG ;
Yeung, AC .
CIRCULATION, 2003, 107 (25) :3129-3132
[8]   PHYSIOLOGIC BASIS FOR ASSESSING CRITICAL CORONARY STENOSIS - INSTANTANEOUS FLOW RESPONSE AND REGIONAL DISTRIBUTION DURING CORONARY HYPEREMIA AS MEASURES OF CORONARY FLOW RESERVE [J].
GOULD, KL ;
LIPSCOMB, K ;
HAMILTON, GW .
AMERICAN JOURNAL OF CARDIOLOGY, 1974, 33 (01) :87-94
[9]   HETEROGENEOUS CHANGES IN EPIMYOCARDIAL MICROVASCULAR SIZE DURING GRADED CORONARY STENOSIS - EVIDENCE OF THE MICROVASCULAR SITE FOR AUTOREGULATION [J].
KANATSUKA, H ;
LAMPING, KG ;
EASTHAM, CL ;
MARCUS, ML .
CIRCULATION RESEARCH, 1990, 66 (02) :389-396
[10]   Coronary microvascular resistance: methods for its quantification in humans [J].
Knaapen, Paul ;
Camici, Paolo G. ;
Marques, Koen M. ;
Nijveldt, Robin ;
Bax, Jeroen J. ;
Westerhof, Nico ;
Gotte, Marco J. W. ;
Jerosch-Herold, Michael ;
Schelbert, Heinrich R. ;
Lammertsma, Adriaan A. ;
van Rossum, Albert C. .
BASIC RESEARCH IN CARDIOLOGY, 2009, 104 (05) :485-498