Comparison of Vascular Responses Following New-Generation Biodegradable and Durable Polymer-Based Drug-Eluting Stent Implantation in an Atherosclerotic Rabbit Iliac Artery Model

被引:36
作者
Nakazawa, Gaku [1 ]
Torii, Sho [1 ]
Ijichi, Takeshi [1 ]
Nagamatsu, Hirofumi [1 ]
Ohno, Yohei [1 ]
Kurata, Fumi [1 ]
Yoshikawa, Ayako [1 ]
Nakano, Masataka [1 ]
Shinozaki, Norihiko [1 ]
Yoshimachi, Fuminobu [1 ]
Ikari, Yuji [1 ]
机构
[1] Tokai Univ, Sch Med, Dept Cardiol, 143 Shimokasuya, Isehara, Kanagawa 2591193, Japan
来源
JOURNAL OF THE AMERICAN HEART ASSOCIATION | 2016年 / 5卷 / 10期
关键词
atherosclerosis; endothelialization; polymer; stent; BARE-METAL STENTS; MYOCARDIAL-INFARCTION; SPIRIT III; THROMBOSIS; RESTENOSIS; PATHOLOGY; TRIAL; PREDICTORS; MICRORNAS; HUMANS;
D O I
10.1161/JAHA.116.003803
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Incomplete endothelialization is the primary substrate of late stent thrombosis; however, recent reports have revealed that abnormal vascular responses are also responsible for the occurrence of late stent failure. The aim of the current study was to assess vascular response following deployment of biodegradable polymer-based Synergy (Boston Scientific) and Nobori (Terumo) drug-eluting stents and the durable polymer-based Resolute Integrity stent (Medtronic) in an atherosclerotic rabbit iliac artery model. Methods and Results-A total of 24 rabbits were fed an atherogenic diet, and then a balloon injury was used to induce atheroma formation. Synergy, Nobori, and Resolute Integrity stents were randomly implanted in iliac arteries. Animals were euthanized at 28 days for scanning electron microscopic evaluation and at 90 days for histological analysis. The percentage of uncovered strut area at 28 days was lowest with Synergy, followed by Resolute Integrity, and was significantly higher with Nobori stents (Synergy 1.1 +/- 2.2%, Resolute Integrity 2.0 +/- 3.9%, Nobori 4.6 +/- 3.0%; P< 0.001). At 90 days, inflammation score was lowest for Synergy (0.27 +/- 0.45), followed by Nobori (0.62 +/- 0.59), and was highest for Resolute Integrity (0.89 +/- 0.46, P< 0.001). Foamy macrophage infiltration within neointima (ie, neoatherosclerosis) was significantly less with Synergy (0.62 +/- 0.82) compared with Nobori (0.85 +/- 0.74) and Resolute Integrity (1.39 +/- 1.32; P=0.034). Conclusions-The biodegradable polymer-coated thin-strut Synergy drug-eluting stent showed the fastest stent strut neointimal coverage and the lowest incidence of neoatherosclerosis in the current animal model.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Comparison of 3 biodegradable polymer and durable polymer-based drug-eluting stents in all-comers (BIO-RESORT): Rationale and study design of the randomized TWENTE III multicenter trial
    Lam, Ming Kai
    Sen, Hanim
    Tandjung, Kenneth
    van Houwelingen, K. Gert
    de Vries, Arie G.
    Danse, Peter W.
    Schotborgh, Carl E.
    Scholte, Martijn
    Lowik, Marije M.
    Linssen, Gerard C. M.
    IJzerman, Maarten J.
    van der Palen, Job
    Doggen, Carine J. M.
    von Birgelen, Clemens
    AMERICAN HEART JOURNAL, 2014, 167 (04) : 445 - 451
  • [42] The Impact of New Generation Drug-Eluting Stent Implantation on Patients with Chronic Kidney Disease and a Single Lesion in the Proximal Segment of the Left Anterior Descending Artery
    Toutouzas, Konstantinos
    Patsa, Chrysoula
    Synetos, Andreas
    Karanasos, Antonis
    Karampelas, John
    Tsiamis, Eleftherios
    Spanos, Anastasios
    Stefanadi, Elli
    Tousoulis, Dimitris
    Stefanadis, Christodoulos
    HELLENIC JOURNAL OF CARDIOLOGY, 2011, 52 (02) : 103 - 110
  • [43] Very long-term outlook of acute coronary syndromes after percutaneous coronary intervention with implantation of polymer-free versus durable-polymer new-generation drug-eluting stents
    Versaci, Francesco
    Kufner, Sebastian
    Cassese, Salvatore
    Joner, Michael
    Mayer, Katharina
    Xhepa, Erion
    Koch, Tobias
    Wiebe, Jens
    Ibrahim, Tareq
    Laugwitz, Karl-Ludwig
    Schunkert, Heribert
    Kastrati, Adnan
    Byrne, Robert A.
    Spagnoli, Alessandra
    Bernardi, Marco
    Spadafora, Luigi
    Biondi-zoccai, Giuseppe
    MINERVA MEDICA, 2023, 114 (05) : 590 - 600
  • [44] One-year clinical outcomes between biodegradable-polymer-coated biolimus-eluting stent and durable-polymer-coated drug-eluting stents in STEMI patients with multivessel coronary artery disease undergoing culprit-only or multivessel PCI
    Kim, Yong Hoon
    Her, Ae-Young
    Jeong, Myung Ho
    Kim, Byeong-Keuk
    Lee, Seung-Yul
    Hong, Sung-Jin
    Ahn, Chul-Min
    Kim, Jung-Sun
    Ko, Young-Guk
    Choi, Donghoon
    Hong, Myeong-Ki
    Jang, Yangsoo
    ATHEROSCLEROSIS, 2019, 284 : 102 - 109
  • [45] Difference of vascular healing between bioabsorbable-polymer and durable-polymer new generation drug-eluting stents: an optical coherence tomographic analysis
    Matsuhiro, Yutaka
    Nakamura, Daisuke
    Shutta, Ryu
    Kawamura, Akito
    Nakamura, Hitoshi
    Okamoto, Naotaka
    Matsunaga-Lee, Yasuharu
    Yano, Masamichi
    Egami, Yasuyuki
    Sakata, Yasushi
    Nishino, Masami
    Tanouchi, Jun
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2021, 37 (04) : 1131 - 1141
  • [46] Serial Assessment of Strut Coverage of Biodegradable Polymer Drug-Eluting Stent at 1, 2, and 3 Months After Stent Implantation by Optical Frequency Domain Imaging The DISCOVERY 1TO3 Study (Evaluation With OFDI of Strut Coverage of Terumo New Drug Eluting Stent With Biodegradable Polymer at 1, 2, and 3 Months)
    Chevalier, Bernard
    Smits, Pieter C.
    Carrie, Didier
    Mehilli, Julinda
    Van Boven, Ad J.
    Regar, Evelyn
    Sawaya, Fadi J.
    Chamie, Daniel
    Kraaijeveld, Adriaan O.
    Hovasse, Thomas
    Vlachojannis, Georgios J.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (12)
  • [47] Improved Safety and Reduction in Stent Thrombosis Associated With Biodegradable Polymer-Based Biolimus-Eluting Stents Versus Durable Polymer-Based Sirolimus-Eluting Stents in Patients With Coronary Artery Disease Final 5-Year Report of the LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) Randomized, Noninferiority Trial
    Serruys, Patrick W.
    Farooq, Vasim
    Kalesan, Bindu
    de Vries, Ton
    Buszman, Pawel
    Linke, Axel
    Ischinger, Thomas
    Klauss, Volker
    Eberli, Franz
    Wijns, William
    Morice, Marie Claude
    Di Mario, Carlo
    Corti, Roberto
    Antoni, Diethmar
    Sohn, Hae Y.
    Eerdmans, Pedro
    Rademaker-Havinga, Tessa
    van Es, Gerrit-Anne
    Meier, Bernhard
    Jueni, Peter
    Windecker, Stephan
    JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (08) : 777 - 789
  • [48] Final 3-Year Outcome of a Randomized Trial Comparing Second-Generation Drug-Eluting Stents Using Either Biodegradable Polymer or Durable Polymer NOBORI Biolimus-Eluting Versus XIENCE/PROMUS Everolimus-Eluting Stent Trial
    Natsuaki, Masahiro
    Kozuma, Ken
    Morimoto, Takeshi
    Kadota, Kazushige
    Muramatsu, Toshiya
    Nakagawa, Yoshihisa
    Akasaka, Takashi
    Igarashi, Keiichi
    Tanabe, Kengo
    Morino, Yoshihiro
    Ishikawa, Tetsuya
    Nishikawa, Hideo
    Awata, Masaki
    Abe, Mitsuru
    Okada, Hisayuki
    Takatsu, Yoshiki
    Ogata, Nobuhiko
    Kimura, Kazuo
    Urasawa, Kazushi
    Tarutani, Yasuhiro
    Shiode, Nobuo
    Kimura, Takeshi
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (10)
  • [49] Comparison of new-generation drug-eluting stents versus drug-coated balloon for in-stent restenosis: a meta-analysis of randomised controlled trials
    Cai, Jin-Zan
    Zhu, Yong-Xiang
    Wang, Xin-Yu
    Bourantas, Christos V.
    Iqbal, Javaid
    Zhu, Hao
    Cummins, Paul
    Dong, Sheng-jie
    Mathur, Anthony
    Zhang, Yao-Jun
    BMJ OPEN, 2018, 8 (02):
  • [50] First-in-man randomised comparison of the Angiolite durable fluoroacrylate polymer-based sirolimus-eluting stent versus a durable fluoropolymer-based everolimus-eluting stent in patiens with coronary artery disease: the ANGIOLITE trial
    Moreu, Jose
    Moreno-Gomez, Raul
    Perez de Prado, Armando
    Garcia del Blanco, Bruno
    Trillo, Ramiro
    Pinar, Eduardo
    Molina, Eduardo
    Zueco, Javier
    Merchan, Antonio
    Francisco Diaz-Fernandez, Jose
    Amat, Ignacio
    EUROINTERVENTION, 2019, 15 (12) : E1081 - U104