Comparison of Vascular Responses Following New-Generation Biodegradable and Durable Polymer-Based Drug-Eluting Stent Implantation in an Atherosclerotic Rabbit Iliac Artery Model

被引:36
|
作者
Nakazawa, Gaku [1 ]
Torii, Sho [1 ]
Ijichi, Takeshi [1 ]
Nagamatsu, Hirofumi [1 ]
Ohno, Yohei [1 ]
Kurata, Fumi [1 ]
Yoshikawa, Ayako [1 ]
Nakano, Masataka [1 ]
Shinozaki, Norihiko [1 ]
Yoshimachi, Fuminobu [1 ]
Ikari, Yuji [1 ]
机构
[1] Tokai Univ, Sch Med, Dept Cardiol, 143 Shimokasuya, Isehara, Kanagawa 2591193, Japan
来源
JOURNAL OF THE AMERICAN HEART ASSOCIATION | 2016年 / 5卷 / 10期
关键词
atherosclerosis; endothelialization; polymer; stent; BARE-METAL STENTS; MYOCARDIAL-INFARCTION; SPIRIT III; THROMBOSIS; RESTENOSIS; PATHOLOGY; TRIAL; PREDICTORS; MICRORNAS; HUMANS;
D O I
10.1161/JAHA.116.003803
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Incomplete endothelialization is the primary substrate of late stent thrombosis; however, recent reports have revealed that abnormal vascular responses are also responsible for the occurrence of late stent failure. The aim of the current study was to assess vascular response following deployment of biodegradable polymer-based Synergy (Boston Scientific) and Nobori (Terumo) drug-eluting stents and the durable polymer-based Resolute Integrity stent (Medtronic) in an atherosclerotic rabbit iliac artery model. Methods and Results-A total of 24 rabbits were fed an atherogenic diet, and then a balloon injury was used to induce atheroma formation. Synergy, Nobori, and Resolute Integrity stents were randomly implanted in iliac arteries. Animals were euthanized at 28 days for scanning electron microscopic evaluation and at 90 days for histological analysis. The percentage of uncovered strut area at 28 days was lowest with Synergy, followed by Resolute Integrity, and was significantly higher with Nobori stents (Synergy 1.1 +/- 2.2%, Resolute Integrity 2.0 +/- 3.9%, Nobori 4.6 +/- 3.0%; P< 0.001). At 90 days, inflammation score was lowest for Synergy (0.27 +/- 0.45), followed by Nobori (0.62 +/- 0.59), and was highest for Resolute Integrity (0.89 +/- 0.46, P< 0.001). Foamy macrophage infiltration within neointima (ie, neoatherosclerosis) was significantly less with Synergy (0.62 +/- 0.82) compared with Nobori (0.85 +/- 0.74) and Resolute Integrity (1.39 +/- 1.32; P=0.034). Conclusions-The biodegradable polymer-coated thin-strut Synergy drug-eluting stent showed the fastest stent strut neointimal coverage and the lowest incidence of neoatherosclerosis in the current animal model.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Association between angiographic and intravascular ultrasound optimizations after new-generation drug-eluting stent implantation and clinical outcomes
    Cha, Jung-Joon
    Kim, Daehoon
    Kim, Byeong-Keuk
    Hong, Sung-Jin
    Ahn, Chul-Min
    Kim, Jung-Sun
    Ko, Young-Guk
    Choi, Donghoon
    Hong, Myeong-Ki
    Jang, Yangsoo
    CORONARY ARTERY DISEASE, 2021, 32 (06) : 541 - 548
  • [32] Two-Year Safety and Efficacy of Biodegradable Polymer Drug-Eluting Stent Versus Second-Generation Durable Polymer Drug-Eluting Stent in Patients With Acute Myocardial Infarction: Data from the Korea Acute Myocardial Infarction Registry (KAMIR)
    Hur, Seung-Ho
    Kim, In-Cheol
    Won, Ki-Bum
    Cho, Yun-Kyeong
    Yoon, Hyuck-Jun
    Nam, Chang-Wook
    Kim, Kwon-Bae
    Kim, Min-Seok
    Park, Jincheol
    Rha, Seung-Woon
    Chae, Shung-Chull
    Kim, Young-Jo
    Kim, Chong-Jin
    Cho, Myeong-Chan
    Jeong, Myung-Ho
    Ahn, Young-Keun
    Kim, Hyo-Soo
    Ahn, Tae-Hoon
    Seung, Ki-Bae
    Jang, Yangsoo
    Yoon, Jung-Han
    Seong, In-Whan
    Hong, Taek-Jong
    Bae, Jang-Ho
    Park, Seung-Jung
    CLINICAL CARDIOLOGY, 2016, 39 (05) : 276 - 284
  • [33] Two-year vascular responses to drug-eluting stents with biodegradable polymer versus durable polymer: An optical coherence tomography sub-study of the NEXT
    Katayama, Yosuke
    Kubo, Takashi
    Akasaka, Takashi
    Ino, Yasushi
    Kimura, Kazuo
    Okura, Hiroyuki
    Shinke, Toshiro
    Igarashi, Keiichi
    Kadota, Kazushige
    Kozuma, Ken
    Tanabe, Kengo
    Nakagawa, Yoshihisa
    Muramatsu, Toshiya
    Morino, Yoshihiro
    Kimura, Takeshi
    JOURNAL OF CARDIOLOGY, 2017, 70 (5-6) : 530 - 536
  • [34] Impact of different coronary angioscopic findings on arterial healing one year after bioresorbable-polymer and second-generation durable-polymer drug-eluting stent implantation
    Nojima, Yuhei
    Adachi, Hidenori
    Ihara, Madoka
    Kurimoto, Tetsuya
    Okayama, Keita
    Sakata, Yasushi
    Nanto, Shinsuke
    JOURNAL OF CARDIOLOGY, 2020, 76 (04) : 371 - 377
  • [35] A propensity score-matched comparison of biodegradable polymer vs second-generation durable polymer drug-eluting stents in a real-world population
    Zhao, Ying Jiao
    Teng, Monica
    Khoo, Ai Leng
    Ananthakrishna, Rajiv
    Yeo, Tiong Cheng
    Lim, Boon Peng
    Loh, Joshua P.
    Chan, Mark Y.
    CARDIOVASCULAR THERAPEUTICS, 2018, 36 (02)
  • [36] Vascular response to percutaneous coronary intervention with biodegradable-polymer vs. new-generation durable-polymer drug-eluting stents: a meta-analysis of optical coherence tomography imaging trials
    Cassese, Salvatore
    Xhepa, Erion
    Ndrepepa, Gjin
    Kufner, Sebastian
    Colleran, Roisin
    Giacoppo, Daniele
    Koppara, Tobias
    Mankerious, Nader
    Byrne, Robert A.
    Laugwitz, Karl-Ludwig
    Schunkert, Heribert
    Fusaro, Massimiliano
    Kastrati, Adnan
    Joner, Michael
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2018, 19 (11) : 1294 - 1301
  • [37] Comparison of endothelial shear stress between ultrathin strut bioresorbable polymer drug-eluting stent vs durable-polymer drug-eluting stent post-stent implantation: An optical coherence tomography substudy from BIOFLOW II
    Beyene, Solomon
    Tufaro, Vincenzo
    Garg, Mohil
    Gkargkoulas, Fotis
    Calderon, Andrea Teira
    Safi, Hannah
    Waksman, Ron
    Windecker, Stephan
    Torii, Ryo
    Melaku, Gebremedhin D.
    Bulant, Carlos A.
    V. Bourantas, Christos
    Blanco, Pablo J.
    Garcia-Garcia, Hector M.
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2024, 61 : 26 - 34
  • [38] High-Dose Drug-Coated Balloon Versus Polymer-Based Drug-Eluting Stent for Femoropopliteal Artery Disease Treatment
    Soga, Yoshimitsu
    Takahara, Mitsuyoshi
    Iida, Osamu
    Tomoi, Yusuke
    Kawasaki, Daizo
    Fujihara, Masahiko
    Kozuki, Amane
    Tanaka, Akiko
    Yamauchi, Yasutaka
    Tobita, Kazuki
    Yamaoka, Terutoshi
    Ichihashi, Shigeo
    Ando, Kenji
    JOURNAL OF ENDOVASCULAR THERAPY, 2024,
  • [39] Early vascular responses to abluminal biodegradable polymer-coated versus circumferential durable polymer- coated newer-generation drug-eluting stents in humans: a pathological study
    Kawagoe, Yasuhito
    Otsuka, Fumiyuki
    Onozuka, Daisuke
    Ishibashi-Ueda, Hatsue
    Ikeda, Yoshihiko
    Ohta-Ogo, Keiko
    Matsumoto, Manabu
    Amemiya, Kisaki
    Asaumi, Yasuhide
    Kataoka, Yu
    Nishimura, Kunihiro
    Miyamoto, Yoshihiro
    Noguchi, Teruo
    V. Finn, Aloke
    Virmani, Renu
    Hatakeyama, Kinta
    Yasuda, Satoshi
    EUROINTERVENTION, 2023, 18 (15) : 1284 - +
  • [40] Poly-l-lactide Polymer-Based Triple Drug-Eluting Stent with Abciximab, Alpha-Lipoic Acid and Sirolimus in Porcine Coronary Restenosis Model
    Park, Jun-Kyu
    Kim, Sung Soo
    Kim, Hyun Kuk
    Nah, Jae-Woon
    Kim, Han Byul
    Bae, In Ho
    Park, Dae Sung
    Shim, Jae Won
    Lee, Min Young
    Kim, Joong Sun
    Koo, Bon-Sang
    Jeong, Kang-Jin
    Jin, Yeong Bae
    Kim, Sun-Uk
    Lee, Sang-Rae
    Na, Joo-Young
    Sim, Doo Sun
    Hong, Young Joon
    Lim, Kyung Seob
    Jeong, Myung Ho
    MACROMOLECULAR RESEARCH, 2020, 28 (01) : 9 - 14