Comparison of Vascular Responses Following New-Generation Biodegradable and Durable Polymer-Based Drug-Eluting Stent Implantation in an Atherosclerotic Rabbit Iliac Artery Model

被引:36
|
作者
Nakazawa, Gaku [1 ]
Torii, Sho [1 ]
Ijichi, Takeshi [1 ]
Nagamatsu, Hirofumi [1 ]
Ohno, Yohei [1 ]
Kurata, Fumi [1 ]
Yoshikawa, Ayako [1 ]
Nakano, Masataka [1 ]
Shinozaki, Norihiko [1 ]
Yoshimachi, Fuminobu [1 ]
Ikari, Yuji [1 ]
机构
[1] Tokai Univ, Sch Med, Dept Cardiol, 143 Shimokasuya, Isehara, Kanagawa 2591193, Japan
来源
JOURNAL OF THE AMERICAN HEART ASSOCIATION | 2016年 / 5卷 / 10期
关键词
atherosclerosis; endothelialization; polymer; stent; BARE-METAL STENTS; MYOCARDIAL-INFARCTION; SPIRIT III; THROMBOSIS; RESTENOSIS; PATHOLOGY; TRIAL; PREDICTORS; MICRORNAS; HUMANS;
D O I
10.1161/JAHA.116.003803
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Incomplete endothelialization is the primary substrate of late stent thrombosis; however, recent reports have revealed that abnormal vascular responses are also responsible for the occurrence of late stent failure. The aim of the current study was to assess vascular response following deployment of biodegradable polymer-based Synergy (Boston Scientific) and Nobori (Terumo) drug-eluting stents and the durable polymer-based Resolute Integrity stent (Medtronic) in an atherosclerotic rabbit iliac artery model. Methods and Results-A total of 24 rabbits were fed an atherogenic diet, and then a balloon injury was used to induce atheroma formation. Synergy, Nobori, and Resolute Integrity stents were randomly implanted in iliac arteries. Animals were euthanized at 28 days for scanning electron microscopic evaluation and at 90 days for histological analysis. The percentage of uncovered strut area at 28 days was lowest with Synergy, followed by Resolute Integrity, and was significantly higher with Nobori stents (Synergy 1.1 +/- 2.2%, Resolute Integrity 2.0 +/- 3.9%, Nobori 4.6 +/- 3.0%; P< 0.001). At 90 days, inflammation score was lowest for Synergy (0.27 +/- 0.45), followed by Nobori (0.62 +/- 0.59), and was highest for Resolute Integrity (0.89 +/- 0.46, P< 0.001). Foamy macrophage infiltration within neointima (ie, neoatherosclerosis) was significantly less with Synergy (0.62 +/- 0.82) compared with Nobori (0.85 +/- 0.74) and Resolute Integrity (1.39 +/- 1.32; P=0.034). Conclusions-The biodegradable polymer-coated thin-strut Synergy drug-eluting stent showed the fastest stent strut neointimal coverage and the lowest incidence of neoatherosclerosis in the current animal model.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Very early neointimal coverage of new biodegradable polymer drug-eluting stent compared with durable polymer everolimus-eluting stent evaluated by optical frequency domain imaging
    Kobayashi, Norihiro
    Ito, Yoshiaki
    Yamawaki, Masahiro
    Araki, Motoharu
    Sakai, Tsuyoshi
    Sakamoto, Yasunari
    Mori, Shinsuke
    Tsutsumi, Masakazu
    Nauchi, Masahiro
    Honda, Yohsuke
    Tokuda, Takahiro
    Makino, Kenji
    Shirai, Shigemitsu
    Hirano, Keisuke
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2018, 34 (04) : 515 - 522
  • [22] Vascular Response to Drug-Eluting Stent With Biodegradable vs. Durable Polymer - Optical Coherence Tomography Substudy of the NEXT
    Kubo, Takashi
    Akasaka, Takashi
    Kozuma, Ken
    Kimura, Kazuo
    Fusazaki, Tetsuya
    Okura, Hiroyuki
    Shinke, Toshiro
    Ino, Yasushi
    Hasegawa, Takao
    Takashima, Hiroaki
    Takamisawa, Itaru
    Yamaguchi, Hiroshi
    Igarashi, Keiichi
    Kadota, Kazushige
    Tanabe, Kengo
    Nakagawa, Yoshihisa
    Muramatsu, Toshiya
    Morino, Yoshihiro
    Kimura, Takeshi
    CIRCULATION JOURNAL, 2014, 78 (10) : 2408 - 2414
  • [23] Biodegradable-polymer-based drug-eluting stent for left main coronary artery disease
    Gutierrez-Chico, J. L.
    Jochheim, D.
    Mehilli, J.
    MINERVA CARDIOANGIOLOGICA, 2013, 61 (05): : 563 - 574
  • [24] New Drug-Eluting Stents An Overview on Biodegradable and Polymer-Free Next-Generation Stent Systems
    Abizaid, Alexandre
    Costa, J. Ribamar, Jr.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (04) : 384 - 393
  • [25] Long-Term Outcomes of Biodegradable Versus Second-Generation Durable Polymer Drug-Eluting Stent Implantations for Myocardial Infarction
    Choe, Jeong Cheon
    Cha, Kwang Soo
    Lee, Jeong Gyu
    Kim, Jinmi
    Shin, Ji Yeon
    Ahn, Jinhee
    Park, Jin Sup
    Lee, Hye Won
    Oh, Jun-Hyok
    Choi, Jung Hyun
    Lee, Han Cheol
    Hong, Taek Jong
    Jeong, Myung Ho
    JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (01) : 97 - 111
  • [26] Ten-year clinical outcomes of polymer-free versus durable polymer new-generation drug-eluting stent in patients with coronary artery disease with and without diabetes mellitus
    Koch, Tobias
    Lenz, Tobias
    Joner, Michael
    Xhepa, Erion
    Koppara, Tobias
    Wiebe, Jens
    Coughlan, J. J.
    Aytekin, Alp
    Ibrahim, Tareq
    Kessler, Thorsten
    Cassese, Salvatore
    Laugwitz, Karl-Ludwig
    Schunkert, Heribert
    Kastrati, Adnan
    Kufner, Sebastian
    CLINICAL RESEARCH IN CARDIOLOGY, 2021, 110 (10) : 1586 - 1598
  • [27] Comparison of 9-Month Angiographic Follow-Up and Long-Term Clinical Outcomes of Biodegradable Polymer Drug-Eluting Stents and Second-Generation Durable Polymer Drug-Eluting Stents in Patients Undergoing Single Coronary Artery Stenting
    Tsai, Ming-Lung
    Hsieh, Ming-Jer
    Chen, Chun-Chi
    Chang, Shang-Hung
    Wang, Chao-Yung
    Chen, Dong-Yi
    Yang, Chia-Hung
    Yeh, Jih-Kai
    Ho, Ming-Yun
    Hsieh, I-Chang
    ACTA CARDIOLOGICA SINICA, 2020, 36 (02) : 97 - 104
  • [28] Angioscopic Assessment of Arterial Repair Following Biodegradable Polymer-Coated Biolimus A9-Eluting Stent Implantation - Comparison With Durable Polymer-Coated Sirolimus-Eluting Stent
    Awata, Masaki
    Uematsu, Masaaki
    Sera, Fusako
    Ishihara, Takayuki
    Watanabe, Tetsuya
    Fujita, Masashi
    Onishi, Toshinari
    Iida, Osamu
    Ishida, Yoshio
    Nanto, Shinsuke
    Nagata, Seiki
    CIRCULATION JOURNAL, 2011, 75 (05) : 1113 - 1119
  • [29] Histopathological comparison of biodegradable polymer and permanent polymer based sirolimus eluting stents in a porcine model of coronary stent implantation
    Koppara, Tobias
    Joner, Michael
    Bayer, Gerd
    Steigerwald, Kristin
    Diener, Tobias
    Wittchow, Eric
    THROMBOSIS AND HAEMOSTASIS, 2012, 107 (06) : 1161 - 1171
  • [30] Comparison of vascular responses after different types of second-generation drug-eluting stents implantation detected by optical coherence tomography
    Ohtani, Hirofumi
    Kimura, Shigeki
    Sugiyama, Tomoyo
    Hishikari, Keiichi
    Misawa, Toru
    Mizusawa, Masafumi
    Hayasaka, Kazuto
    Yamakami, Yosuke
    Kojima, Keisuke
    Sagawa, Yuichiro
    Hikita, Hiroyuki
    Ashikaga, Takashi
    Takahashi, Atsushi
    Isobe, Mitsuaki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (02) : 177 - 186