Cost-Effectiveness of a Radio Frequency Hemostatic Sealer (RFHS) in Adult Spinal Deformity Surgery

被引:2
作者
Gandhoke, Gurpreet S. [1 ]
Smith, Kenneth J. [2 ,3 ]
Pandya, Yash K. [4 ]
Alan, Nima [4 ]
Kanter, Adam S. [4 ]
Okonkwo, David O. [4 ]
机构
[1] St Lukes Hosp, Dept Neurosurg, Kansas City, MO 64111 USA
[2] Univ Pittsburgh, Dept Med, Pittsburgh, PA USA
[3] Univ Pittsburgh, Clin & Translat Sci Inst, Pittsburgh, PA USA
[4] Univ Pittsburgh, Med Ctr, Dept Neurosurg, Pittsburgh, PA USA
关键词
Cost-effectiveness; Radiofrequency hemostatic sealer; Spine deformity surgery; BLOOD-TRANSFUSION; BIPOLAR SEALER; ARTHROPLASTY; PROGRAM; US;
D O I
10.1016/j.wneu.2018.10.131
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Patients undergoing posterior spinal fusion surgery can lose a substantial amount of blood. This can prolong operative time and require transfusion of allogeneic blood components, which increases the risk of infection and can be the harbinger of serious complications. Does a saline-irrigated bipolar radiofrequency hemostatic sealer (RFHS) help reduce transfusion requirements? METHODS: In an observational cohort study, we compared transfusion requirements in 30 patients undergoing surgery for adult spinal deformity using the RFHS with that of a historical control group of 30 patients in which traditional hemostasis was obtained with bipolar electrocautery and matched them for blood loss-related variables. Total expense to the hospital for the RFHS, laboratory expenses, and blood transfusions was used for cost calculations. The incremental cost-effectiveness ratio was calculated using the number of blood transfusions avoided as the effectiveness payoff. RESULTS: Using a multivariable linear regression model, we found that only estimated blood loss (EBL) was an independent significant predictor of transfusion requirement in both groups. We evaluated the variables of age, EBL, time duration of surgery, preoperative hemoglobin, hemoglobin nadir during surgery, body mass index, length of stay, and number of levels operated on. Mean EBL was greater in the control group (2201 vs. 1416 mL, P = 0.0099). The number of transfusions also was greater in the control group (14.5 vs. 6.5, P = 0.0008). In the cost-effectiveness analysis, we found that the RFHS cost $108 more (compared with not using the RFHS) to avoid 1 unit of blood transfusion. CONCLUSIONS: The cost-effectiveness analysis revealed that if we are willing to pay $108 to avoid 1 unit of blood transfusion, the use of the RFHS is a reasonable choice to use in open surgery for adult spinal deformity.
引用
收藏
页码:171 / 175
页数:5
相关论文
共 13 条
  • [1] Tranexamic acid reduces blood transfusion in total knee arthroplasty even when a blood conservation program is applied
    Alvarez, Juan C.
    Santiveri, Francisco X.
    Ramos, Isabel
    Vela, Enrique
    Puig, Lluis
    Escolano, Fernando
    [J]. TRANSFUSION, 2008, 48 (03) : 519 - 525
  • [2] Prospective Randomized Evaluation of the Need for Blood Transfusion During Primary Total Hip Arthroplasty with Use of a Bipolar Sealer
    Barsoum, Wael K.
    Klika, Alison K.
    Murray, Trevor G.
    Higuera, Carlos
    Lee, Ho H.
    Krebs, Viktor E.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (06) : 513 - 518
  • [3] Radiofrequency bipolar hemostatic sealer reduces blood loss, transfusion requirements, and cost for patients undergoing multilevel spinal fusion surgery: a case control study
    Frank, Steven M.
    Wasey, Jack O.
    Dwyer, Ian M.
    Gokaslan, Ziya L.
    Ness, Paul M.
    Kebaish, Khaled M.
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2014, 9
  • [4] Geller David A, 2005, HPB (Oxford), V7, P208, DOI 10.1080/13651820510028945
  • [5] Use of a Bipolar Blood-Sealing System During Total Joint Arthroplasty
    Huang, ZeYu
    Ma, Jun
    Shen, Bin
    Yang, Jing
    Zhou, ZongKe
    Kang, PengDe
    Pei, FuXing
    [J]. ORTHOPEDICS, 2015, 38 (12) : 757 - 763
  • [6] Hemostasis With a Bipolar Sealer During Surgical Correction of Adolescent Idiopathic Scoliosis
    Mankin, Keith P.
    Moore, Christopher A.
    Miller, Larry E.
    Block, Jon E.
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2012, 25 (05): : 259 - 263
  • [7] Reductions in blood loss with a bipolar sealer in total hip arthroplasty
    Marulanda, German A.
    Ulrich, Slif D.
    Seyler, Thorsten M.
    Delanois, Ronald E.
    Mont, Michael A.
    [J]. EXPERT REVIEW OF MEDICAL DEVICES, 2008, 5 (02) : 125 - 131
  • [8] Marulanda German A, 2005, Surg Technol Int, V14, P281
  • [9] Paul JE, 2007, CAN J ANAESTH, V54, P799, DOI 10.1007/BF03021707
  • [10] Spending on health in the US is projected to reach almost 20% of GDP by 2022
    Roehr, Bob
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2013, 347