Performance study of a dual-function roof solar collector for Chinese traditional buildings application

被引:21
|
作者
Hu, Zhongting [1 ,2 ]
Luo, Bingqing [2 ]
He, Wei [1 ]
Hu, Dengyun [2 ]
Ji, Jie [2 ]
Ma, Jinwei [3 ]
机构
[1] Hefei Univ Technol, Dept Bldg Environm & Equipment, Hefei 230009, Anhui, Peoples R China
[2] Univ Sci & Technol China, Dept Thermal Sci & Energy Engn, Hefei 230026, Anhui, Peoples R China
[3] Anhui Jianzhu Univ, Sch Environm & Energy Engn, Hefei 230601, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
Chinese traditional buildings; Modelling; Roof solar collector; Thermal efficiency; NUMERICAL-SIMULATION; THERMAL PERFORMANCE; AIR COLLECTORS; DESIGN; SYSTEM; DYNAMICS; ENERGY; CFD;
D O I
10.1016/j.applthermaleng.2017.09.019
中图分类号
O414.1 [热力学];
学科分类号
摘要
Architectural integration is a crucial issue in the development and spreading of solar collectors, especially in China, where several traditional buildings have pitch roof with tiles. In this paper, a novel roof solar collector (Type 1) providing hot water and space heating is designed to enable effective collection of solar heat as well integrating naturally. A dynamic numerical model is developed and validated with experimental data. The simulation of the Type 1 collector demonstrates its good characteristics regarding to the thermal insulation and transmission of solar radiation. A linear correlation between the instantaneous efficiency and the reduced temperature is established. Simulated results of the Type 1 collector are further compared with the other two types of roof solar collectors (i.e., Type 2 and Type 3). The comparisons indicated that the similar maximum instantaneous efficiency are achieved. However, the Type 1 collector is preferred as its heat loss coefficient is 54.4% lower compared to the Type 2 collector, and is 65.8% lower compared to the Type 3 collector. The afore-mentioned results confirm that the Type 1 collector introduced has potential to address the issue on the poor architectural quality of roof integrated solar collectors for Chinese traditional buildings. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:179 / 188
页数:10
相关论文
共 50 条
  • [31] Experimental and numerical study of the impact of the collector roof inclination on the performance of a solar chimney power plant
    Ayadi, Ahmed
    Driss, Zied
    Bouabidi, Abdallah
    Abid, Mohamed Salah
    ENERGY AND BUILDINGS, 2017, 139 : 263 - 276
  • [32] Experimental study of natural convection in PV roof solar collector
    Phiraphat, Sahachai
    Prommas, Ratthasak
    Puangsombut, Withaya
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2017, 89 : 31 - 38
  • [33] Effects of Novel Collector Roof on Solar Chimney Power Plant Performance
    Elwekeel, Fifi N. M.
    Abdala, Antar M. M.
    Rahman, Muhammad Mustafizur
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2019, 141 (03):
  • [34] Study for dual-function EUV multilayer mirror
    Wang, Li-Hui
    Wang, Xiao-Kun
    Chen, Bo
    OPTICS AND LASER TECHNOLOGY, 2008, 40 (03): : 571 - 574
  • [35] Dual-function interface engineering for efficient perovskite solar cells
    Luan, Yigang
    Wang, Fuhui
    Zhuang, Jing
    Lin, Tao
    Wei, Yuanzhi
    Chen, Ningli
    Zhang, Yanyan
    Wang, Fuyi
    Yu, Ping
    Mao, Lanqun
    Liu, Huibiao
    Wang, Jizheng
    ECOMAT, 2021, 3 (02)
  • [36] Performance Modelling of Dual Air/Water Collector in Solar Water and Space Heating Application
    Shemelin, Viacheslav
    Matuska, Tomas
    INTERNATIONAL JOURNAL OF PHOTOENERGY, 2019, 2019
  • [37] Active solar collector located on roof ridge assisted Chinese solar greenhouse for thermal environment enhancement
    Hu, Yixin
    Miao, Lili
    Song, Lei
    Li, Chenhao
    Xiao, Jinxin
    Wang, Hao
    Cao, Yanfei
    Sun, Guotao
    Li, Jianming
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2022, 44 (04) : 8959 - 8979
  • [38] Novel dual-function racking structure for passive cooling of solar PV panels -thermal performance analysis
    Al-Amri, Fahad
    Saeed, Farooq
    Mujeebu, Muhammad Abdul
    RENEWABLE ENERGY, 2022, 198 : 100 - 113
  • [39] Experimental and numerical analysis of the collector roof height effect on the solar chimney performance
    Ayadi, Ahmed
    Bouabidi, Abdallah
    Driss, Zied
    Abid, Mohamed Salah
    RENEWABLE ENERGY, 2018, 115 : 649 - 662
  • [40] Determination of optimum location and tilt angle of solar collector on the roof of buildings with regard to shadow of adjacent neighbors
    Moghadam, Hamid
    Deymeh, Saeed Moghadam
    SUSTAINABLE CITIES AND SOCIETY, 2015, 14 : 215 - 222