Membrane fouling performance of Fe-based coagulation-ultrafiltration process: Effect of sedimentation time

被引:16
作者
Ding, Yanyan [1 ,2 ,3 ]
Li, Tong [4 ,5 ]
Qiu, Kaipei [6 ]
Ma, Baiwen [2 ]
Wu, Ruijun [7 ]
机构
[1] Tongji Univ, Sch Environm Sci & Engn, State Key Lab Pollut Control & Resource Reuse, Shanghai 200092, Peoples R China
[2] Chinese Acad Sci, Res Ctr Ecoenvironm Sci, Key Lab Drinking Water Sci & Technol, Beijing 100085, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] Guangzhou Univ, Inst Environm Res Greater Bay Area, Guangzhou 510006, Peoples R China
[5] Guangzhou Univ, Key Lab Water Qual & Conservat Pearl River Delta, Minist Educ, Guangzhou 510006, Peoples R China
[6] East China Univ Sci & Technol, Sch Resources & Environm Engn, Shanghai 200237, Peoples R China
[7] Tianjin Motimo Membrane Technol Co Ltd, State Key Lab Membrane Mat & Membrane Applicat, Tianjin 300457, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Ultrafiltration; Coagulation; Floc; Sedimentation time; Fouling behavior; LOW-PRESSURE MEMBRANES; DRINKING-WATER TREATMENT; HYDROLYTIC FLOCS; HUMIC-ACID; PRETREATMENT; LAYERS; AL; MECHANISMS; FOULANTS; PLANTS;
D O I
10.1016/j.envres.2021.110756
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Pre-coagulation is commonly used with ultrafiltration (UF) to alleviate the membrane fouling. Compared to conventional coagulation-sedimentation-UF (CSUF) processes, the direct coagulation-UF (CUF) processes are widely believed to perform better due to the formation of a looser cake layer. It is however shown in this study that not only the density of a cake layer, but also its thickness as well, can affect the membrane fouling behavior, which therefore are influenced by both the sedimentation time and flocs characteristics. Herein, the membrane fouling performance of Fe-based coagulation-UF process was systematically investigated with different sedimentation times. A critical threshold of 30 min was observed at the lab-scale: if shorter than that, the membrane fouling depended mainly on the cake layer density, and thus CUF outperformed CSUF; but when the sedimentation time was over 30 min, the cake layer thickness turned to be the dominant factor, thereby resulting in CSUF performing better. Furthermore, it was shown that the critical sedimentation time was decided by flocs characteristics. A lower water temperature induced the formation of irregular flocs with a lower fractal dimension, and the corresponding cake layer exhibited an almost identical density with increasing sedimentation time. In this regard, CSUF processes were constantly superior to CUF as the cake layer thickness decreased. On the other hand, a critical sedimentation time reappeared because of the higher floc fractal dimension under acidic conditions. This work showed for the first time that the membrane fouling of CSUF was up to the sedimentation time, and it was possible to outperform CUF if the sedimentation time exceeded a critical threshold. Such a finding is crucial to the future development of coagulation integrated UF processes.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Continuation of a cleaning process: Application of MNBs-coagulation process to mitigate ultrafiltration membrane fouling
    Huang, Xiaojiang
    Chen, Kunyu
    Zhang, Zhiqiang
    Pang, Heliang
    Huang, Xingxing
    Yang, Jing
    Wang, Xuan
    Lu, Jinsuo
    WATER RESEARCH, 2024, 250
  • [42] Performance and properties of coking nanofiltration concentrate treatment and membrane fouling mitigation by an Fe(ii)/persulfate-coagulation-ultrafiltration process
    Yang, Ming
    Chen, Jiabin
    Peng, Boyu
    Yu, Zhenjiang
    Chu, Huaqiang
    Zhou, Xuefei
    RSC ADVANCES, 2019, 9 (27): : 15277 - 15287
  • [43] Application of Al species in coagulation/ultrafiltration process: Influence of cake layer on membrane fouling
    Wang, Wenyu
    Yue, Qinyan
    Guo, Kangying
    Bu, Fan
    Shen, Xue
    Gao, Baoyu
    JOURNAL OF MEMBRANE SCIENCE, 2019, 572 : 161 - 170
  • [44] Impacts of epichlorohydrin-dimethylamine on coagulation performance and membrane fouling in coagulation/ultrafiltration combined process with different Al-based coagulants
    Bu, Fan
    Gao, Baoyu
    Li, Ruihua
    Sun, Shenglei
    Yue, Qinyan
    CHEMOSPHERE, 2016, 159 : 228 - 234
  • [45] Fulvic acid removal performance and control of disinfection by-product formation potential in coagulation-ultrafiltration process
    Wang, Yan
    Mao, Ranran
    Wang, Qian
    Yang, Zhonglian
    Gao, Baoyu
    Zhao, Yanxia
    DESALINATION, 2012, 302 : 55 - 64
  • [46] Combined effects of PAC adsorption and in situ chlorination on membrane fouling in a pilot-scale coagulation and ultrafiltration process
    Wang, Hui
    Qu, Fangshu
    Ding, An
    Liang, Heng
    Jia, Ruibao
    Li, Kai
    Bai, Langming
    Chang, Haiqing
    Li, Guibai
    CHEMICAL ENGINEERING JOURNAL, 2016, 283 : 1374 - 1383
  • [47] Titanium tetrachloride for silver nanoparticle-humic acid composite contaminant removal in coagulation-ultrafiltration hybrid process: floc property and membrane fouling
    Zhao, Yanxia
    Sun, Yangyang
    Tian, Chang
    Gao, Baoyu
    Wang, Yan
    Shon, Hokyong
    Yang, Yanzhao
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2017, 24 (02) : 1757 - 1768
  • [48] Characterizing synergistic effect of coagulant aid and membrane fouling during coagulation-ultrafiltration via in-situ Raman spectroscopy and electrochemical impedance spectroscopy
    Tang, Juan
    Jia, Hui
    Mu, Situ
    Gao, Fei
    Qin, Qingwen
    Wang, Jie
    WATER RESEARCH, 2020, 172
  • [49] Improvement of virus removal by pilot-scale coagulation-ultrafiltration process for wastewater reclamation: Effect of optimization of pH in secondary effluent
    Lee, S.
    Ihara, M.
    Yamashita, N.
    Tanaka, H.
    WATER RESEARCH, 2017, 114 : 23 - 30
  • [50] Effect of potassium permanganate dosing position on the performance of coagulation/ultrafiltration combined process
    Zhao, He
    Wang, Liang
    Zhang, Hongwei
    Wu, Xiaona
    Zhao, Bin
    Han, Fei
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2018, 26 (01) : 89 - 95