Membrane fouling performance of Fe-based coagulation-ultrafiltration process: Effect of sedimentation time

被引:16
|
作者
Ding, Yanyan [1 ,2 ,3 ]
Li, Tong [4 ,5 ]
Qiu, Kaipei [6 ]
Ma, Baiwen [2 ]
Wu, Ruijun [7 ]
机构
[1] Tongji Univ, Sch Environm Sci & Engn, State Key Lab Pollut Control & Resource Reuse, Shanghai 200092, Peoples R China
[2] Chinese Acad Sci, Res Ctr Ecoenvironm Sci, Key Lab Drinking Water Sci & Technol, Beijing 100085, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] Guangzhou Univ, Inst Environm Res Greater Bay Area, Guangzhou 510006, Peoples R China
[5] Guangzhou Univ, Key Lab Water Qual & Conservat Pearl River Delta, Minist Educ, Guangzhou 510006, Peoples R China
[6] East China Univ Sci & Technol, Sch Resources & Environm Engn, Shanghai 200237, Peoples R China
[7] Tianjin Motimo Membrane Technol Co Ltd, State Key Lab Membrane Mat & Membrane Applicat, Tianjin 300457, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Ultrafiltration; Coagulation; Floc; Sedimentation time; Fouling behavior; LOW-PRESSURE MEMBRANES; DRINKING-WATER TREATMENT; HYDROLYTIC FLOCS; HUMIC-ACID; PRETREATMENT; LAYERS; AL; MECHANISMS; FOULANTS; PLANTS;
D O I
10.1016/j.envres.2021.110756
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Pre-coagulation is commonly used with ultrafiltration (UF) to alleviate the membrane fouling. Compared to conventional coagulation-sedimentation-UF (CSUF) processes, the direct coagulation-UF (CUF) processes are widely believed to perform better due to the formation of a looser cake layer. It is however shown in this study that not only the density of a cake layer, but also its thickness as well, can affect the membrane fouling behavior, which therefore are influenced by both the sedimentation time and flocs characteristics. Herein, the membrane fouling performance of Fe-based coagulation-UF process was systematically investigated with different sedimentation times. A critical threshold of 30 min was observed at the lab-scale: if shorter than that, the membrane fouling depended mainly on the cake layer density, and thus CUF outperformed CSUF; but when the sedimentation time was over 30 min, the cake layer thickness turned to be the dominant factor, thereby resulting in CSUF performing better. Furthermore, it was shown that the critical sedimentation time was decided by flocs characteristics. A lower water temperature induced the formation of irregular flocs with a lower fractal dimension, and the corresponding cake layer exhibited an almost identical density with increasing sedimentation time. In this regard, CSUF processes were constantly superior to CUF as the cake layer thickness decreased. On the other hand, a critical sedimentation time reappeared because of the higher floc fractal dimension under acidic conditions. This work showed for the first time that the membrane fouling of CSUF was up to the sedimentation time, and it was possible to outperform CUF if the sedimentation time exceeded a critical threshold. Such a finding is crucial to the future development of coagulation integrated UF processes.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Insight into the influence of humic acid and sodium alginate fractions on membrane fouling in coagulation-ultrafiltration combined system
    Zhao, Changwei
    Song, Tingting
    Yu, Yang
    Qu, Laiye
    Cheng, Jinxing
    Zhu, Wenkai
    Wang, Qingbo
    Li, Pei
    Tang, Wenjing
    ENVIRONMENTAL RESEARCH, 2020, 191
  • [32] Effect of pH on humic acid removal performance in coagulation-ultrafiltration process and the subsequent effects on chlorine decay
    Wang, Qian
    Gao, Baoyu
    Wang, Yan
    Yang, Zhonglian
    Xu, Weiying
    Yue, Qinyan
    SEPARATION AND PURIFICATION TECHNOLOGY, 2011, 80 (03) : 549 - 555
  • [33] Contribution of specific extracellular organic matter on membrane fouling in ultrafiltration and coagulation-ultrafiltration of algae-laden water
    Qiu, Xiaopeng
    Liu, Zijun
    Li, Xianpeng
    Wang, Yangtao
    Wang, Xingtong
    Zhang, Yaozhong
    Li, Jiake
    Li, Xiaoliang
    Cao, Xin
    Zheng, Xing
    INTERNATIONAL BIODETERIORATION & BIODEGRADATION, 2025, 196
  • [34] Impacts of organic coagulant aid on purification performance and membrane fouling of coagulation/ultrafiltration hybrid process with different Al-based coagulants
    Xu, Weiying
    Yue, Qinyan
    Gao, Baoyu
    Du, Bin
    DESALINATION, 2015, 363 : 126 - 133
  • [35] Effect of adsorption and coagulation pretreatment sequence on ultrafiltration membrane fouling: Process study and targeted prediction
    Chen, Meng
    Nan, Jun
    Ji, Xiaoyu
    Wu, Fangmin
    Ye, Xuesong
    Ge, Zhencheng
    DESALINATION, 2022, 540
  • [36] The dye or humic acid water treatment and membrane fouling by polyaluminum chloride composited with sodium alginate in coagulation-ultrafiltration process
    Wang, Yan
    Zhang, Feng
    Chu, Yongbao
    Gao, Baoyu
    Yue, Qinyan
    WATER SCIENCE AND TECHNOLOGY, 2013, 67 (10) : 2202 - 2209
  • [37] Pre-coagulation on the submerged membrane fouling in nano-scale: Effect of sedimentation process
    Yu, Wen-Zheng
    Qu, Jiu-Hui
    Gregory, John
    CHEMICAL ENGINEERING JOURNAL, 2015, 262 : 676 - 682
  • [38] Effect of shear conditions on floc properties and membrane fouling in coagulation/ultrafiltration hybrid process-The significance of Alb species
    Xu, Weiying
    Gao, Baoyu
    JOURNAL OF MEMBRANE SCIENCE, 2012, 415 : 153 - 160
  • [39] Effect of landfill leachate ageing on ultrafiltration performance and membrane fouling behaviour
    Collado, Sergio
    Nunez, Daniel
    Oulego, Paula
    Riera, Francisco A.
    Diaz, Mario
    JOURNAL OF WATER PROCESS ENGINEERING, 2020, 36
  • [40] Alleviating membrane fouling of modified polysulfone membrane via coagulation pretreatment/ultrafiltration hybrid process
    Yu, Chenghui
    Gao, Baoyu
    Wang, Wenyu
    Xu, Xing
    Yue, Qinyan
    CHEMOSPHERE, 2019, 235 : 58 - 69