Membrane fouling performance of Fe-based coagulation-ultrafiltration process: Effect of sedimentation time

被引:16
|
作者
Ding, Yanyan [1 ,2 ,3 ]
Li, Tong [4 ,5 ]
Qiu, Kaipei [6 ]
Ma, Baiwen [2 ]
Wu, Ruijun [7 ]
机构
[1] Tongji Univ, Sch Environm Sci & Engn, State Key Lab Pollut Control & Resource Reuse, Shanghai 200092, Peoples R China
[2] Chinese Acad Sci, Res Ctr Ecoenvironm Sci, Key Lab Drinking Water Sci & Technol, Beijing 100085, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] Guangzhou Univ, Inst Environm Res Greater Bay Area, Guangzhou 510006, Peoples R China
[5] Guangzhou Univ, Key Lab Water Qual & Conservat Pearl River Delta, Minist Educ, Guangzhou 510006, Peoples R China
[6] East China Univ Sci & Technol, Sch Resources & Environm Engn, Shanghai 200237, Peoples R China
[7] Tianjin Motimo Membrane Technol Co Ltd, State Key Lab Membrane Mat & Membrane Applicat, Tianjin 300457, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
Ultrafiltration; Coagulation; Floc; Sedimentation time; Fouling behavior; LOW-PRESSURE MEMBRANES; DRINKING-WATER TREATMENT; HYDROLYTIC FLOCS; HUMIC-ACID; PRETREATMENT; LAYERS; AL; MECHANISMS; FOULANTS; PLANTS;
D O I
10.1016/j.envres.2021.110756
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Pre-coagulation is commonly used with ultrafiltration (UF) to alleviate the membrane fouling. Compared to conventional coagulation-sedimentation-UF (CSUF) processes, the direct coagulation-UF (CUF) processes are widely believed to perform better due to the formation of a looser cake layer. It is however shown in this study that not only the density of a cake layer, but also its thickness as well, can affect the membrane fouling behavior, which therefore are influenced by both the sedimentation time and flocs characteristics. Herein, the membrane fouling performance of Fe-based coagulation-UF process was systematically investigated with different sedimentation times. A critical threshold of 30 min was observed at the lab-scale: if shorter than that, the membrane fouling depended mainly on the cake layer density, and thus CUF outperformed CSUF; but when the sedimentation time was over 30 min, the cake layer thickness turned to be the dominant factor, thereby resulting in CSUF performing better. Furthermore, it was shown that the critical sedimentation time was decided by flocs characteristics. A lower water temperature induced the formation of irregular flocs with a lower fractal dimension, and the corresponding cake layer exhibited an almost identical density with increasing sedimentation time. In this regard, CSUF processes were constantly superior to CUF as the cake layer thickness decreased. On the other hand, a critical sedimentation time reappeared because of the higher floc fractal dimension under acidic conditions. This work showed for the first time that the membrane fouling of CSUF was up to the sedimentation time, and it was possible to outperform CUF if the sedimentation time exceeded a critical threshold. Such a finding is crucial to the future development of coagulation integrated UF processes.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Effect of pH with different purified aluminum species on coagulation performance and membrane fouling in coagulation/ultrafiltration process
    Feng, Lijuan
    Zhao, Shuang
    Sun, Shenglei
    Wang, Wenyu
    Gao, Baoyu
    Yue, Qinyan
    JOURNAL OF HAZARDOUS MATERIALS, 2015, 300 : 67 - 74
  • [22] Application of combined coagulation-ultrafiltration membrane process for water treatment
    Jung, CW
    Kang, LS
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2003, 20 (05) : 855 - 861
  • [23] Application of combined coagulation-ultrafiltration membrane process for water treatment
    Chul-Woo Jung
    Lim-Seok Kang
    Korean Journal of Chemical Engineering, 2003, 20 : 855 - 861
  • [24] Preozonation Effects on Organic Foulants in a Coagulation-Ultrafiltration Membrane Process
    Biscardi, Paul G.
    Duranceau, Steven J.
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 2017, 109 (02): : 15 - 24
  • [25] Unveiling the role of cake layer in coagulation-ultrafiltration on membrane fouling and emerging application as dynamic membrane before ultrafiltration
    Liu, Yatao
    Wang, Zhenbei
    Xu, Mingyao
    Qi, Fei
    Li, Chen
    Sun, Dezhi
    Nan, Jun
    Li, Wei
    Guan, Xiao
    Ikhlaq, Amir
    SEPARATION AND PURIFICATION TECHNOLOGY, 2024, 350
  • [26] The impact of optimised coagulation on membrane fouling for coagulation/ultrafiltration process
    Dixon, Mike
    Staaks, Christian
    Fabris, Rolando
    Vimonses, Vipasiri
    Chow, Christopher W. K.
    Panglisch, Stefan
    van Leeuwen, John A.
    Drikas, Mary
    DESALINATION AND WATER TREATMENT, 2013, 51 (13-15) : 2718 - 2725
  • [27] Effects of epichlorohydrin-dimethylamine on coagulation and membrane performance of ferric chloride in coagulation-ultrafiltration hybrid process
    Sun, Shenglei
    Bu, Fan
    Huang, Xin
    Zhao, Shuang
    Dong, Hongyu
    Gao, Baoyu
    Yue, Qinyan
    Feng, Lijuan
    Wang, Yan
    Li, Qian
    CHEMICAL ENGINEERING JOURNAL, 2015, 280 : 634 - 642
  • [28] Performance of a coagulation-ultrafiltration hybrid process for water supply treatment
    Bergamasco, Rosangela
    Konradt-Moraes, Leila Cristina
    Vieira, Marcelo Fernandes
    Fagundes-Klen, Marcia Regina
    Salcedo Vieira, Angelica Marquetotti
    CHEMICAL ENGINEERING JOURNAL, 2011, 166 (02) : 483 - 489
  • [29] Effect of coagulation pretreatment on the fouling of ultrafiltration membrane
    Dong Bing-zhi
    Chen Yan
    Gao Nai-yun
    Fan Jin-chu
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2007, 19 (03) : 278 - 283