Membrane fouling performance of Fe-based coagulation-ultrafiltration process: Effect of sedimentation time

被引:16
|
作者
Ding, Yanyan [1 ,2 ,3 ]
Li, Tong [4 ,5 ]
Qiu, Kaipei [6 ]
Ma, Baiwen [2 ]
Wu, Ruijun [7 ]
机构
[1] Tongji Univ, Sch Environm Sci & Engn, State Key Lab Pollut Control & Resource Reuse, Shanghai 200092, Peoples R China
[2] Chinese Acad Sci, Res Ctr Ecoenvironm Sci, Key Lab Drinking Water Sci & Technol, Beijing 100085, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] Guangzhou Univ, Inst Environm Res Greater Bay Area, Guangzhou 510006, Peoples R China
[5] Guangzhou Univ, Key Lab Water Qual & Conservat Pearl River Delta, Minist Educ, Guangzhou 510006, Peoples R China
[6] East China Univ Sci & Technol, Sch Resources & Environm Engn, Shanghai 200237, Peoples R China
[7] Tianjin Motimo Membrane Technol Co Ltd, State Key Lab Membrane Mat & Membrane Applicat, Tianjin 300457, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Ultrafiltration; Coagulation; Floc; Sedimentation time; Fouling behavior; LOW-PRESSURE MEMBRANES; DRINKING-WATER TREATMENT; HYDROLYTIC FLOCS; HUMIC-ACID; PRETREATMENT; LAYERS; AL; MECHANISMS; FOULANTS; PLANTS;
D O I
10.1016/j.envres.2021.110756
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Pre-coagulation is commonly used with ultrafiltration (UF) to alleviate the membrane fouling. Compared to conventional coagulation-sedimentation-UF (CSUF) processes, the direct coagulation-UF (CUF) processes are widely believed to perform better due to the formation of a looser cake layer. It is however shown in this study that not only the density of a cake layer, but also its thickness as well, can affect the membrane fouling behavior, which therefore are influenced by both the sedimentation time and flocs characteristics. Herein, the membrane fouling performance of Fe-based coagulation-UF process was systematically investigated with different sedimentation times. A critical threshold of 30 min was observed at the lab-scale: if shorter than that, the membrane fouling depended mainly on the cake layer density, and thus CUF outperformed CSUF; but when the sedimentation time was over 30 min, the cake layer thickness turned to be the dominant factor, thereby resulting in CSUF performing better. Furthermore, it was shown that the critical sedimentation time was decided by flocs characteristics. A lower water temperature induced the formation of irregular flocs with a lower fractal dimension, and the corresponding cake layer exhibited an almost identical density with increasing sedimentation time. In this regard, CSUF processes were constantly superior to CUF as the cake layer thickness decreased. On the other hand, a critical sedimentation time reappeared because of the higher floc fractal dimension under acidic conditions. This work showed for the first time that the membrane fouling of CSUF was up to the sedimentation time, and it was possible to outperform CUF if the sedimentation time exceeded a critical threshold. Such a finding is crucial to the future development of coagulation integrated UF processes.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Comprehensive effects of microplastics on algae-laden surface water treatment by coagulation-ultrafiltration combined process: Algae cultivation, coagulation performance and membrane fouling development
    Lin, Dachao
    Zhuang, Zhongjian
    Yu, Nan
    Wang, Zhihong
    Song, Wei
    Du, Xing
    SCIENCE OF THE TOTAL ENVIRONMENT, 2024, 924
  • [22] Integrated Fe-based floc-membrane process for alleviating ultrafiltration membrane fouling by humic acid and reservoir water
    Ma, Baiwen
    Xue, Wenjing
    Li, Wenjiang
    Hu, Chengzhi
    Liu, Huijuan
    Qu, Jiuhui
    JOURNAL OF MEMBRANE SCIENCE, 2018, 563 : 873 - 881
  • [23] Coagulation-ultrafiltration integrated process for membrane fouling control: Influence of Al species and SUVA values of water
    Yan, Mengjiao
    Shen, Xue
    Gao, Baoyu
    Guo, Kangying
    Yue, Qinyan
    SCIENCE OF THE TOTAL ENVIRONMENT, 2021, 793
  • [24] Effect of pH with different purified aluminum species on coagulation performance and membrane fouling in coagulation/ultrafiltration process
    Feng, Lijuan
    Zhao, Shuang
    Sun, Shenglei
    Wang, Wenyu
    Gao, Baoyu
    Yue, Qinyan
    JOURNAL OF HAZARDOUS MATERIALS, 2015, 300 : 67 - 74
  • [25] Characterization of dissolved organic matter and membrane fouling in coagulation-ultrafiltration process treating micro-polluted surface water
    Fan Bu
    Baoyu Gao
    Qinyan Yue
    Xue Shen
    Wenyu Wang
    Journal of Environmental Sciences, 2019, 75 (01) : 318 - 324
  • [26] Membrane fouling control by Ca2+ during coagulation-ultrafiltration process for algal-rich water treatment
    Ma, Cong
    Huang, Jingyun
    Wang, Yulan
    Wang, Liang
    Zhang, Hongwei
    Ran, Zhilin
    McCutcheon, Jeffrey R.
    ENVIRONMENTAL GEOCHEMISTRY AND HEALTH, 2020, 42 (03) : 809 - 818
  • [27] Coagulation performance and membrane fouling of polyferric chloride/epichlorohydrin-dimethylamine in coagulation/ultrafiltration combined process
    Sun, Shenglei
    Yang, Zhonglian
    Huang, Xin
    Bu, Fan
    Ma, Defang
    Dong, Hongyu
    Gao, Baoyu
    Yue, Qinyan
    Wang, Yan
    Li, Qian
    DESALINATION, 2015, 357 : 163 - 170
  • [28] Effects of epichlorohydrin-dimethylamine on coagulation and membrane performance of ferric chloride in coagulation-ultrafiltration hybrid process
    Sun, Shenglei
    Bu, Fan
    Huang, Xin
    Zhao, Shuang
    Dong, Hongyu
    Gao, Baoyu
    Yue, Qinyan
    Feng, Lijuan
    Wang, Yan
    Li, Qian
    CHEMICAL ENGINEERING JOURNAL, 2015, 280 : 634 - 642
  • [29] Coagulation efficiency, floc properties and membrane fouling of polyaluminum chloride in coagulation-ultrafiltration system: The role of magnesium
    Zhao, Shuang
    Gao, Baoyu
    Sun, Shenglei
    Yue, Qinyan
    Dong, Hongyu
    Song, Wen
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2015, 469 : 235 - 241
  • [30] Biologically Enhanced Coagulation-Ultrafiltration Process for Healthy Water Production with Low Fouling Propensity
    Xu, Lei
    Li, Shuo
    Graham, Nigel J. D.
    Yu, Wenzheng
    ACS ES&T ENGINEERING, 2022, 2 (01): : 78 - 91