Membrane fouling performance of Fe-based coagulation-ultrafiltration process: Effect of sedimentation time

被引:16
作者
Ding, Yanyan [1 ,2 ,3 ]
Li, Tong [4 ,5 ]
Qiu, Kaipei [6 ]
Ma, Baiwen [2 ]
Wu, Ruijun [7 ]
机构
[1] Tongji Univ, Sch Environm Sci & Engn, State Key Lab Pollut Control & Resource Reuse, Shanghai 200092, Peoples R China
[2] Chinese Acad Sci, Res Ctr Ecoenvironm Sci, Key Lab Drinking Water Sci & Technol, Beijing 100085, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] Guangzhou Univ, Inst Environm Res Greater Bay Area, Guangzhou 510006, Peoples R China
[5] Guangzhou Univ, Key Lab Water Qual & Conservat Pearl River Delta, Minist Educ, Guangzhou 510006, Peoples R China
[6] East China Univ Sci & Technol, Sch Resources & Environm Engn, Shanghai 200237, Peoples R China
[7] Tianjin Motimo Membrane Technol Co Ltd, State Key Lab Membrane Mat & Membrane Applicat, Tianjin 300457, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
Ultrafiltration; Coagulation; Floc; Sedimentation time; Fouling behavior; LOW-PRESSURE MEMBRANES; DRINKING-WATER TREATMENT; HYDROLYTIC FLOCS; HUMIC-ACID; PRETREATMENT; LAYERS; AL; MECHANISMS; FOULANTS; PLANTS;
D O I
10.1016/j.envres.2021.110756
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Pre-coagulation is commonly used with ultrafiltration (UF) to alleviate the membrane fouling. Compared to conventional coagulation-sedimentation-UF (CSUF) processes, the direct coagulation-UF (CUF) processes are widely believed to perform better due to the formation of a looser cake layer. It is however shown in this study that not only the density of a cake layer, but also its thickness as well, can affect the membrane fouling behavior, which therefore are influenced by both the sedimentation time and flocs characteristics. Herein, the membrane fouling performance of Fe-based coagulation-UF process was systematically investigated with different sedimentation times. A critical threshold of 30 min was observed at the lab-scale: if shorter than that, the membrane fouling depended mainly on the cake layer density, and thus CUF outperformed CSUF; but when the sedimentation time was over 30 min, the cake layer thickness turned to be the dominant factor, thereby resulting in CSUF performing better. Furthermore, it was shown that the critical sedimentation time was decided by flocs characteristics. A lower water temperature induced the formation of irregular flocs with a lower fractal dimension, and the corresponding cake layer exhibited an almost identical density with increasing sedimentation time. In this regard, CSUF processes were constantly superior to CUF as the cake layer thickness decreased. On the other hand, a critical sedimentation time reappeared because of the higher floc fractal dimension under acidic conditions. This work showed for the first time that the membrane fouling of CSUF was up to the sedimentation time, and it was possible to outperform CUF if the sedimentation time exceeded a critical threshold. Such a finding is crucial to the future development of coagulation integrated UF processes.
引用
收藏
页数:9
相关论文
共 39 条
[21]   Effect of low dosage of coagulant on the ultrafiltration membrane performance in feedwater treatment [J].
Ma, Baiwen ;
Yu, Wenzheng ;
Liu, Huijuan ;
Qu, Jiuhui .
WATER RESEARCH, 2014, 51 :277-283
[22]  
Malkoske TA, 2020, ENVIRON SCI-WAT RES, V6, P2993, DOI [10.1039/d0ew00461h, 10.1039/D0EW00461H]
[23]   Hybrid coagulation/membrane process treatment applied to the treatment of industrial dyeing effluent [J].
Masmoudi, Ghazza ;
Ellouze, Emna ;
Ben Amar, Raja .
DESALINATION AND WATER TREATMENT, 2016, 57 (15) :6781-6791
[24]   Determination of cake porosity using image analysis in a coagulation-microfiltration system [J].
Park, Pyung-Kyu ;
Lee, Chung-Hak ;
Lee, Sangho .
JOURNAL OF MEMBRANE SCIENCE, 2007, 293 (1-2) :66-72
[25]   Characterization of UF foulants and fouling mechanisms when applying low in-line coagulant pre-treatment [J].
Peleato, Nicolas M. ;
Legge, Raymond L. ;
Andrews, Robert C. .
WATER RESEARCH, 2017, 126 :1-11
[26]   Removal of tinidazole from waters by using ozone and activated carbon in dynamic regime [J].
Rivera-Utrilla, J. ;
Sanchez-Polo, M. ;
Prados-Joya, G. ;
Ferro-Garcia, M. A. ;
Bautista-Toledo, I. .
JOURNAL OF HAZARDOUS MATERIALS, 2010, 174 (1-3) :880-886
[27]   Characterization and influence of floc under different coagulation systems on ultrafiltration membrane fouling [J].
Shen, Xue ;
Gao, Baoyu ;
Guo, Kangying ;
Yue, Qinyan .
CHEMOSPHERE, 2020, 238
[28]   Implications of advanced wastewater treatment: Electrocoagulation and electroflocculation of effluent discharged from a wastewater treatment plant [J].
Sher, Farooq ;
Hanif, Kashif ;
Iqbal, Sania Zafar ;
Imran, Muhammad .
JOURNAL OF WATER PROCESS ENGINEERING, 2020, 33
[29]   The challenges of water governance in Ho Chi Minh City [J].
van Leeuwen, Cornelis J. ;
Dan, Nguyen P. ;
Dieperink, Carel .
INTEGRATED ENVIRONMENTAL ASSESSMENT AND MANAGEMENT, 2016, 12 (02) :345-352
[30]  
Wang J., ENVIRON RES, V188