Membrane fouling performance of Fe-based coagulation-ultrafiltration process: Effect of sedimentation time

被引:16
|
作者
Ding, Yanyan [1 ,2 ,3 ]
Li, Tong [4 ,5 ]
Qiu, Kaipei [6 ]
Ma, Baiwen [2 ]
Wu, Ruijun [7 ]
机构
[1] Tongji Univ, Sch Environm Sci & Engn, State Key Lab Pollut Control & Resource Reuse, Shanghai 200092, Peoples R China
[2] Chinese Acad Sci, Res Ctr Ecoenvironm Sci, Key Lab Drinking Water Sci & Technol, Beijing 100085, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] Guangzhou Univ, Inst Environm Res Greater Bay Area, Guangzhou 510006, Peoples R China
[5] Guangzhou Univ, Key Lab Water Qual & Conservat Pearl River Delta, Minist Educ, Guangzhou 510006, Peoples R China
[6] East China Univ Sci & Technol, Sch Resources & Environm Engn, Shanghai 200237, Peoples R China
[7] Tianjin Motimo Membrane Technol Co Ltd, State Key Lab Membrane Mat & Membrane Applicat, Tianjin 300457, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Ultrafiltration; Coagulation; Floc; Sedimentation time; Fouling behavior; LOW-PRESSURE MEMBRANES; DRINKING-WATER TREATMENT; HYDROLYTIC FLOCS; HUMIC-ACID; PRETREATMENT; LAYERS; AL; MECHANISMS; FOULANTS; PLANTS;
D O I
10.1016/j.envres.2021.110756
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Pre-coagulation is commonly used with ultrafiltration (UF) to alleviate the membrane fouling. Compared to conventional coagulation-sedimentation-UF (CSUF) processes, the direct coagulation-UF (CUF) processes are widely believed to perform better due to the formation of a looser cake layer. It is however shown in this study that not only the density of a cake layer, but also its thickness as well, can affect the membrane fouling behavior, which therefore are influenced by both the sedimentation time and flocs characteristics. Herein, the membrane fouling performance of Fe-based coagulation-UF process was systematically investigated with different sedimentation times. A critical threshold of 30 min was observed at the lab-scale: if shorter than that, the membrane fouling depended mainly on the cake layer density, and thus CUF outperformed CSUF; but when the sedimentation time was over 30 min, the cake layer thickness turned to be the dominant factor, thereby resulting in CSUF performing better. Furthermore, it was shown that the critical sedimentation time was decided by flocs characteristics. A lower water temperature induced the formation of irregular flocs with a lower fractal dimension, and the corresponding cake layer exhibited an almost identical density with increasing sedimentation time. In this regard, CSUF processes were constantly superior to CUF as the cake layer thickness decreased. On the other hand, a critical sedimentation time reappeared because of the higher floc fractal dimension under acidic conditions. This work showed for the first time that the membrane fouling of CSUF was up to the sedimentation time, and it was possible to outperform CUF if the sedimentation time exceeded a critical threshold. Such a finding is crucial to the future development of coagulation integrated UF processes.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Influence of sedimentation with pre-coagulation on ultrafiltration membrane fouling performance
    Ma, Baiwen
    Ding, Yanyan
    Wang, Bodong
    Qi, Zenglu
    Bai, Yaohui
    Liu, Ruiping
    Liu, Huijuan
    Qu, Jiuhui
    SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 708 (708)
  • [2] Effect of the dosage ratio and the viscosity of PAC/PDMDAAC on coagulation performance and membrane fouling in a hybrid coagulation-ultrafiltration process
    Shen, Xue
    Gao, Baoyu
    Huang, Xin
    Bu, Fan
    Yue, Qinyan
    Li, Ruihua
    Jin, Bo
    CHEMOSPHERE, 2017, 173 : 288 - 298
  • [3] Enhanced ultrafiltration membrane fouling alleviation by module rotation with Fe-based flocs
    Miao, Rui
    Qiu, Kaipei
    Wang, Bodong
    Wei, Xiping
    Zuo, Jiaqi
    Ma, Baiwen
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2021, 9 (05):
  • [4] Effect of coagulant dose and backflush pressure on NOM membrane fouling in inline coagulation-ultrafiltration
    Kaminska, Gabriela
    Pronk, Wouter
    Traber, Jacqueline
    DESALINATION AND WATER TREATMENT, 2020, 199 : 188 - 197
  • [5] Application of a novel zirconium coagulant in the coagulation-ultrafiltration process: Fluoride removal and membrane fouling alleviation
    Qu, Le
    Gan, Yonghai
    Xu, Bin
    Wu, Bingdang
    Wu, Wei
    Huang, Tianyin
    Kong, Ming
    Chao, Jianying
    Ding, Chengcheng
    Cui, Yibin
    CHEMICAL ENGINEERING JOURNAL, 2023, 478
  • [6] Probing the application of a zirconium coagulant in a coagulation-ultrafiltration process: observations on organics removal and membrane fouling
    Su, Zhaoyang
    Li, Xing
    Yang, Yanling
    Fan, Yiran
    RSC ADVANCES, 2017, 7 (67): : 42329 - 42338
  • [7] Performance of a coagulation-ultrafiltration hybrid process for water supply treatment
    Bergamasco, Rosangela
    Konradt-Moraes, Leila Cristina
    Vieira, Marcelo Fernandes
    Fagundes-Klen, Marcia Regina
    Salcedo Vieira, Angelica Marquetotti
    CHEMICAL ENGINEERING JOURNAL, 2011, 166 (02) : 483 - 489
  • [8] Effect of coagulation pretreatment on the fouling of ultrafiltration membrane
    Dong Bing-zhi
    Chen Yan
    Gao Nai-yun
    Fan Jin-chu
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2007, 19 (03) : 278 - 283
  • [10] Effect of coagulation pretreatment on fouling of an ultrafiltration membrane
    Chen, Y.
    Dong, B. Z.
    Gao, N. Y.
    Fan, J. C.
    DESALINATION, 2007, 204 (1-3) : 181 - 188