Quantification of Renal Perfusion: Comparison of Arterial Spin Labeling and Dynamic Contrast-Enhanced MRI

被引:50
作者
Winter, Jeff D. [1 ]
St Lawrence, Keith S. [2 ,3 ]
Cheng, Hai-Ling Margaret [1 ,4 ]
机构
[1] Hosp Sick Children, Res Inst, Toronto, ON M5G 1X8, Canada
[2] Lawson Hlth Res Inst, Imaging Div, London, ON, Canada
[3] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
[4] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
perfusion; arterial spin labeling; dynamic contrast enhanced MRI; kidney; cortex; rabbit; BLOOD-FLOW; KIDNEYS;
D O I
10.1002/jmri.22660
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To provide the first comparison of absolute renal perfusion obtained by arterial spin labeling (ASL) and separable compartment modeling of dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI). Moreover, we provide the first application of the dual bolus approach to quantitative DCE-MRI perfusion measurements in the kidney. Materials and Methods: Consecutive ASL and DCE-MRI acquisitions were performed on six rabbits on a 1.5 T MRI system. Gadolinium (Gd)-DTPA was administered in two separate injections to decouple measurement of the arterial input function and tissue uptake curves. For DCE perfusion, pixel-wise and mean cortex region-of-interest tissue curves were fit to a separable compartment model. Results: Absolute renal cortex perfusion estimates obtained by DCE and ASL were in close agreement: 3.28 +/- 0.59 mL/g/min (ASL), 2.98 +/- 0.60 mL/g/min (DCE), and 3.57 +/- 0.96 mL/g/min (pixel-wise DCE). Renal medulla perfusion was 1.53 +/- 0.35 mL/g/min (ASL) but was not adequately described by the separable compartment model. Conclusion: ASL and DCE-MRI provided similar measures of absolute perfusion in the renal cortex, offering both noncontrast and contrast-based alternatives to improve current renal MRI assessment of kidney function.
引用
收藏
页码:608 / 615
页数:8
相关论文
共 33 条
[1]   FAILURE TO ABOLISH REACTIVE HYPEREMIA BY INDOMETHACIN IN DENERVATED KIDNEYS OF RABBITS [J].
AIZAWA, C ;
HONDA, N .
AMERICAN JOURNAL OF PHYSIOLOGY, 1977, 233 (02) :F89-F93
[2]   Glomerular filtration rate: Assessment with dynamic contrast-enhanced MRI and a cortical-compartment model in the rabbit kidney [J].
Annet, L ;
Hermoye, L ;
Peeters, F ;
Jamar, F ;
Dehoux, JP ;
Van Beers, BE .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (05) :843-849
[3]   Normothermic blood perfusion of isolated rabbit kidneys -: II.: In vitro evaluation of renal function followed by orthotopic transplantation [J].
Arnaud, FG ;
Khirabadi, BS ;
Fahy, GM .
ASAIO JOURNAL, 2000, 46 (06) :707-718
[4]   Morphological, contrast-enhanced and spin labeling perfusion imaging for monitoring of relapse after RF ablation of renal cell carcinomas [J].
Boss, Andreas ;
Martirosian, Petros ;
Schraml, Christina ;
Clasen, Stephan ;
Fenchel, Michael ;
Anastasiadis, Artistotelis ;
Claussen, Claus D. ;
Pereira, Philippe L. ;
Schick, Fritz .
EUROPEAN RADIOLOGY, 2006, 16 (06) :1226-1236
[5]   Measurement of single kidney function using dynamic contrast-enhanced MRI: Comparison of two models in human subjects [J].
Buckley, David L. ;
Shurrab, Ala'a E. ;
Cheung, Ching M. ;
Jones, Andrew P. ;
Mamtora, Hari ;
Kalra, Philip A. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (05) :1117-1123
[6]   Rapid high-resolution T1 mapping by variable flip angles:: Accurate and precise measurements in the presence of radiofrequency field inhomogeneity [J].
Cheng, HLM ;
Wright, GA .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (03) :566-574
[7]   The importance of AIF ROI selection in DCE-MRI renography: Reproducibility and variability of renal perfusion and filtration [J].
Cutajar, M. ;
Mendichovszky, I. A. ;
Tofts, P. S. ;
Gordon, I. .
EUROPEAN JOURNAL OF RADIOLOGY, 2010, 74 (03) :E155-E161
[8]   MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: Preliminary results [J].
de Bazelaire, CMJ ;
Duhamel, GD ;
Rofsky, NM ;
Alsop, DC .
RADIOLOGY, 2004, 230 (03) :652-659
[9]   Quantification of renal perfusion and function on a voxel-by-voxel basis: A feasibility study [J].
Dujardin, M ;
Sourbron, S ;
Luypaert, R ;
Verbeelen, D ;
Stadnik, T .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (04) :841-849
[10]  
Evans RG, 2000, ACTA PHYSIOL SCAND, V169, P297