Performance comparison of dispersive solid-phase extraction and multiplug filtration cleanup methods for the determination of tefuryltrione in plant and environmental samples using UHPLC-MS/MS

被引:3
|
作者
Yu, Yang [1 ]
Tao, Yan [2 ]
Dong, Fengshou [2 ]
Xu, Jun [2 ]
Liu, Xingang [2 ]
Wu, Xiaohu [2 ]
Ji, Mingshan [1 ]
Zheng, Yongquan [2 ]
机构
[1] Shenyang Agr Univ, Coll Plant Protect, Shenyang 110161, Liaoning, Peoples R China
[2] Chinese Acad Agr Sci, State Key Lab Biol Plant Dis & Insect Pests, Inst Plant Protect, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
herbicides; sample treatment; tandem mass spectrometry; tefuryltrione; ultra high performance liquid chromatography; TANDEM MASS-SPECTROMETRY; WALLED CARBON NANOTUBES; LIQUID-CHROMATOGRAPHY; PESTICIDE-RESIDUES; SAFE METHOD; HERBICIDES; SPINACH; QUICK; CHEAP;
D O I
10.1002/jssc.201700452
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The detection frequencies of tefuryltrione, a new type of 4-hydroxyphenyl-pyruvate dioxygenase inhibitor herbicide, are rarely reported, probably because of the paucity of analytical methods. Herein, an effective and sensitive analytical method has been developed to detect tefuryltrione in vegetables (tomato and cucumber), cereals (rice and corn), soil, and water by ultra high performance liquid chromatography coupled with tandem mass spectrometry. Comparisons of the performances of dispersive solid-phase extraction and multiplug filtration cleanup methods were carried out for tefuryltrione in complex matrices. Extraction solvents and purification sorbents were further optimized for dispersive solid-phase extraction. Tefuryltrione was analyzed with electrospray ionization in the positive mode within 2.0 min. Mean recoveries for tefuryltrione were 75.4-108.9% with relative standard deviations less than 11.0% at three fortification levels (10, 100, 500 mu g/kg) in the sample matrixes. Limits of quantification ranged from 0.70 to 5.12 mu g/kg, and an excellent linearity (R-2 >= 0.9902) was obtained for tefuryltrione at concentrations of 5-1000 mu g/L. The results showed that the developed dispersive solid-phase extraction method could serve as an effective, sensitive, and robust method for routine monitoring of tefuryltrione residue in plants and environmental samples.
引用
收藏
页码:4420 / 4430
页数:11
相关论文
共 50 条
  • [41] Flow analysis-solid phase extraction system and UHPLC-MS/MS analytical methodology for the determination of antiviral drugs in surface water
    Mermer, Karolina
    Jas, Emilia
    Paluch, Justyna
    Woźniakiewicz, Aneta
    Woźniakiewicz, Michal
    Miśkowiec, Pawel
    Chocholouš, Petr
    Sklenářová, Hana
    Kozak, Joanna
    Environmental Science and Pollution Research, 2024, 31 (37) : 49546 - 49559
  • [42] Determination of Sulfoxaflor in Animal Origin Foods Using Dispersive Solid-Phase Extraction and Multiplug Filtration Cleanup Method Based on Multiwalled Carbon Nanotubes by Ultraperformance Liquid Chromatography/Tandem Mass Spectrometry
    Tian, Chunyan
    Xu, Jun
    Dong, Fengshou
    Liu, Xingang
    Wu, Xiaohu
    Zhao, Huanhuan
    Ju, Chao
    Wei, Dongmei
    Zheng, Yongquan
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2016, 64 (12) : 2641 - 2646
  • [43] Determination of macrolide antibiotics residues in pork using molecularly imprinted dispersive solid-phase extraction coupled with LC-MS/MS
    Song, Xuqin
    Zhou, Tong
    Li, Jiufeng
    Su, Yijuan
    Xie, Jingmeng
    He, Limin
    JOURNAL OF SEPARATION SCIENCE, 2018, 41 (05) : 1138 - 1148
  • [44] Polypyrrole-modified magnetic multi-walled carbon nanotube-based magnetic solid-phase extraction combined with dispersive liquid-liquid microextraction followed by UHPLC-MS/MS for the analysis of sulfonamides in environmental water samples
    Yuan, Xucan
    Wu, Di
    Liu, Chu
    Li, Xianhui
    Xiong, Zhili
    Zhao, Longshan
    NEW JOURNAL OF CHEMISTRY, 2018, 42 (24) : 19578 - 19590
  • [45] Simultaneous Determination of Veterinary Drugs in Livestock Products Using Dispersive and Cartridge Column Solid-Phase Extraction by LC-MS/MS
    Yamaguchi, Takahiro
    Kakimoto, Kensaku
    Nagayoshi, Haruna
    Yamaguchi, Mizuka
    Okihashi, Masahiro
    Kajimura, Keiji
    Yamamoto, Yoshimasa
    FOOD HYGIENE AND SAFETY SCIENCE, 2013, 54 (04): : 290 - 297
  • [46] Simultaneous determination of quinolone and β-lactam residues in raw cow milk samples using ultrasound-assisted extraction and dispersive-SPE prior to UHPLC-MS/MS analysis
    Dorival-Garcia, Noemi
    Junza, Alexandra
    Zafra-Gomez, Alberto
    Barron, Dolores
    Navalon, Alberto
    FOOD CONTROL, 2016, 60 : 382 - 393
  • [47] Optimization of a Solid-Phase Extraction Method for the Determination of 12 Aminoglycosides in Water Samples Using LC-ESI-MS/MS
    Mokh, Samia
    El Hawari, Khaled
    Nassar, Rania
    Budzinski, Helene
    Al Iskandarani, Mohamad
    CHROMATOGRAPHIA, 2015, 78 (9-10) : 631 - 640
  • [48] Quantification of phenolic compounds in vegetable oils by mixed-mode solid-phase extraction isotope chemical labeling coupled with UHPLC-MS/MS
    Yu, Xu
    Yu, Li
    Ma, Fei
    Li, Peiwu
    FOOD CHEMISTRY, 2021, 334
  • [50] Collaborative compounding of metal?organic frameworks for dispersive solid-phase extraction HPLC?MS/MS determination of tetracyclines in honey
    Pang, Yue-Hong
    Lv, Zhi-Yang
    Sun, Ji-Cheng
    Yang, Cheng
    Shen, Xiao-Fang
    FOOD CHEMISTRY, 2021, 355