Performance comparison of dispersive solid-phase extraction and multiplug filtration cleanup methods for the determination of tefuryltrione in plant and environmental samples using UHPLC-MS/MS

被引:3
|
作者
Yu, Yang [1 ]
Tao, Yan [2 ]
Dong, Fengshou [2 ]
Xu, Jun [2 ]
Liu, Xingang [2 ]
Wu, Xiaohu [2 ]
Ji, Mingshan [1 ]
Zheng, Yongquan [2 ]
机构
[1] Shenyang Agr Univ, Coll Plant Protect, Shenyang 110161, Liaoning, Peoples R China
[2] Chinese Acad Agr Sci, State Key Lab Biol Plant Dis & Insect Pests, Inst Plant Protect, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
herbicides; sample treatment; tandem mass spectrometry; tefuryltrione; ultra high performance liquid chromatography; TANDEM MASS-SPECTROMETRY; WALLED CARBON NANOTUBES; LIQUID-CHROMATOGRAPHY; PESTICIDE-RESIDUES; SAFE METHOD; HERBICIDES; SPINACH; QUICK; CHEAP;
D O I
10.1002/jssc.201700452
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The detection frequencies of tefuryltrione, a new type of 4-hydroxyphenyl-pyruvate dioxygenase inhibitor herbicide, are rarely reported, probably because of the paucity of analytical methods. Herein, an effective and sensitive analytical method has been developed to detect tefuryltrione in vegetables (tomato and cucumber), cereals (rice and corn), soil, and water by ultra high performance liquid chromatography coupled with tandem mass spectrometry. Comparisons of the performances of dispersive solid-phase extraction and multiplug filtration cleanup methods were carried out for tefuryltrione in complex matrices. Extraction solvents and purification sorbents were further optimized for dispersive solid-phase extraction. Tefuryltrione was analyzed with electrospray ionization in the positive mode within 2.0 min. Mean recoveries for tefuryltrione were 75.4-108.9% with relative standard deviations less than 11.0% at three fortification levels (10, 100, 500 mu g/kg) in the sample matrixes. Limits of quantification ranged from 0.70 to 5.12 mu g/kg, and an excellent linearity (R-2 >= 0.9902) was obtained for tefuryltrione at concentrations of 5-1000 mu g/L. The results showed that the developed dispersive solid-phase extraction method could serve as an effective, sensitive, and robust method for routine monitoring of tefuryltrione residue in plants and environmental samples.
引用
收藏
页码:4420 / 4430
页数:11
相关论文
共 50 条
  • [1] Determination of seven parabens in surface water samples by UHPLC-MS/MS and solid-phase extraction
    Thuy, Quan Cam
    Phuong, Pham Thi
    Thien, Tran Lam Thanh
    Minh, Bui Quang
    VIETNAM JOURNAL OF CHEMISTRY, 2022, 60 (06) : 738 - 743
  • [2] Determination of triazole fungicides in environmental water by magnetic solid-phase extraction coupled with UHPLC-MS/MS
    Sun, Peng
    Gao, Yuling
    Lian, Yongfu
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2019, 16 (07) : 1483 - 1489
  • [3] Determination of triazole fungicides in environmental water by magnetic solid-phase extraction coupled with UHPLC-MS/MS
    Peng Sun
    Yuling Gao
    Yongfu Lian
    Journal of the Iranian Chemical Society, 2019, 16 : 1483 - 1489
  • [4] Simultaneous determination of seven pesticide residues in soil samples using ultrasound-assisted dispersive solid-phase extraction combined with UHPLC-MS/MS
    Guan, Jin
    Li, Dongjing
    Guo, Yiguang
    Shi, Shuang
    Yan, Feng
    SEPARATION SCIENCE PLUS, 2018, 1 (04): : 296 - 305
  • [5] Simultaneous Determination of γ-Oryzanol in Agriproducts by Solid-Phase Extraction Coupled with UHPLC-MS/MS
    Lv, Lei
    Zhang, Liangxiao
    Gao, Mengxiang
    Ma, Fei
    AGRICULTURE-BASEL, 2023, 13 (03):
  • [6] Determination of six parabens in biological samples by magnetic solid-phase extraction with magnetic mesoporous carbon adsorbent and UHPLC-MS/MS
    Zhang, Qianchun
    Zhi, Yongzhi
    Bao, Linchun
    Zheng, Yuguo
    Wang, Xingyi
    Jiang, Li
    Wu, Yun
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1179
  • [7] SOLID-PHASE EXTRACTION COMBINED WITH UHPLC-MS/MS METHOD FOR DETERMINATION OF REMIFENTANIL IN HUMAN WHOLE BLOOD
    Lv, Jinling
    Li, Yanhua
    Jin, Hua
    Shi, Yao
    Xia, Qinghai
    Yang, Yaling
    ANALYTICAL LETTERS, 2012, 45 (10) : 1133 - 1142
  • [8] Determination of 9 fentanyl drugs in environmental water by UHPLC-MS/ MS combined with solid phase extraction
    Ning, Hongyu
    Xu, Yu
    Wang, Haixing
    Liu, Huijun
    Huang, Zhongping
    Fan, Yilei
    Ke, Xing
    She, Yuanbin
    MICROCHEMICAL JOURNAL, 2024, 201
  • [9] Sensitive determination of gentamicin in plasma using ion-exchange solid-phase extraction followed by UHPLC-MS/MS analysis
    dos Santos, Ana Laura Anibaletto
    da Silva, Anne Caroline Cezimbra
    Lizot, Lilian de Lima Feltraco
    Schneider, Anelise
    Hahn, Roberta Zilles
    Meireles, Yasmin Fazenda
    Pagnussat, Lidiane Riva
    Nonnenmacher, Julia Livia
    Hahn, Siomara Regina
    Linden, Rafael
    PRACTICAL LABORATORY MEDICINE, 2021, 26
  • [10] Determination of 26 endocrine disrupting chemicals in fish and water using modified QuEChERS combined with solid-phase extraction and UHPLC-MS/MS
    Yang, Mei
    Ma, Youning
    Gui, Wenjun
    Ren, Yiping
    Zhu, Guonian
    Liu, Yihua
    ANALYTICAL METHODS, 2015, 7 (19) : 8418 - 8431