Portable and Disposable Paper-Based Fluorescent Sensor for In Situ Gaseous Hydrogen Sulfide Determination in Near Real-Time

被引:51
作者
da Silveira Petruci, Joao Flavio [1 ]
Cardoso, Arnaldo Alves [1 ]
机构
[1] Sao Paulo State Univ UNESP, Dept Analyt Chem, BR-14800060 Araraquara, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
SULFUR-COMPOUNDS RSCS; MERCURIC ACETATE; GAS; AIR; DIOXIDE; PRECONCENTRATION; ATMOSPHERE; DETECTORS; COMPOSITE; SUBSTRATE;
D O I
10.1021/acs.analchem.6b03325
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hydrogen sulfide is found in many environments including sewage systems, petroleum extraction platforms, kraft paper mills, and exhaled breath, but its determination at ppb levels remains a challenge within the analytical chemistry field. Off-line methods for analysis of gaseous reduced sulfur compounds can suffer from a variety of biases associated with high reactivity, sorptive losses, and atmospheric oxidative reactions. Here, we present a portable, I online, and disposable gas sensor platform for the in situ determination of gaseous hydrogen sulfide, employing a 470 run light emitting diode (LED) and a microfiber optic USB spectrometer. A sensing layer was created by impregnating 2.5 mu L (0.285 nmol) of fluorescein mercury acetate (FMA) onto the surface of a micropaper analytical device with dimensions of 5 x 5 nun, which was then positioned in the optical detection system. The quantitative determination of H2S was based on the quenching of fluorescence intensity after direct selective reaction between the gas and FMA. This approach enabled linear calibration within the range 17-67 ppb of H2S, with a limit of detection of 3 ppb. The response time of the sensor was within 60 s, and the repeatability was 6.5% (RSD). The sensor was employed to monitor H2S released from a mini-scale wastewater treatment tank in a research laboratory. The appropriate integration of optoelectronic and mechanical devices, including LED, photodiode, pumps, and electronic boards, can be used to produce simple, fully automated portable sensors for the in situ determination of H2S in a variety of environments.
引用
收藏
页码:11714 / 11719
页数:6
相关论文
共 45 条
[11]   Sensitive luminescent paper-based sensor for the determination of gaseous hydrogen sulfide [J].
da Silveira Petruci, Joao Flavio ;
Cardoso, Arnaldo Alves .
ANALYTICAL METHODS, 2015, 7 (06) :2687-2692
[12]   Real-time monitoring of ozone in air using substrate-integrated hollow waveguide mid-infrared sensors [J].
da Silveira Petruci, Joao Flavio ;
Fortes, Paula Regina ;
Kokoric, Vjekoslav ;
Wilk, Andreas ;
Raimundo, Ivo Milton, Jr. ;
Cardoso, Arnaldo Alves ;
Mizaikoff, Boris .
SCIENTIFIC REPORTS, 2013, 3
[13]   A new palladium chelate compound for determination of sulfide [J].
da Silveira Petruci, Joao Flavio ;
Cardoso, Arnaldo Alves .
MICROCHEMICAL JOURNAL, 2013, 106 :368-372
[14]   LIGHT-EMITTING DIODE BASED FLOW-THROUGH OPTICAL-ABSORPTION DETECTORS [J].
DASGUPTA, PK ;
BELLAMY, HS ;
LIU, HH ;
LOPEZ, JL ;
LOREE, EL ;
MORRIS, K ;
PETERSEN, K ;
MIR, KA .
TALANTA, 1993, 40 (01) :53-74
[15]   Light emitting diode-based detectors absorbance, fluorescence and spectroelectrochemical measurements in a planar flow-through cell [J].
Dasgupta, PK ;
Eom, IY ;
Morris, KJ ;
Li, JZ .
ANALYTICA CHIMICA ACTA, 2003, 500 (1-2) :337-364
[16]   A Method for Determination of Ammonia in Air using Oxalic Acid-Impregnated Cellulose Filters and Fluorimetric Detection [J].
Felix, Erika P. ;
Cardoso, Arnaldo A. .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2012, 23 (01) :142-147
[17]   A new fluorescence method for determination of ozone in ambient air [J].
Felix, Erika P. ;
Passaretti Filho, Juliano ;
Garcia, Gabriel ;
Cardoso, Arnaldo A. .
MICROCHEMICAL JOURNAL, 2011, 99 (02) :530-534
[18]   New fluorescent zinc complexes: towards specific sensors for hydrogen sulfide in solution [J].
Galardon, Erwan ;
Tomas, Alain ;
Roussel, Pascal ;
Artaud, Isabelle .
DALTON TRANSACTIONS, 2009, (42) :9126-9130
[19]   Hydrogen Sulfide: Advances in Understanding Human Toxicity [J].
Guidotti, Tee L. .
INTERNATIONAL JOURNAL OF TOXICOLOGY, 2010, 29 (06) :569-581
[20]   Evaluation of Portable Single-Gas Monitors for the Detection of Low Levels of Hydrogen Sulfide and Sulfur Dioxide in Petroleum Industry Environments [J].
Hemingway, M. A. ;
Walsh, P. T. ;
Hardwick, K. R. ;
Wilcox, G. .
JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2012, 9 (05) :319-328