Thermodynamic balancing of a fixed-size two-stage humidification dehumidification desalination system

被引:68
作者
Chehayeb, Karim M. [1 ]
Narayan, G. Prakash [2 ]
Zubair, Syed M. [3 ]
Lienhard, John H. [1 ]
机构
[1] MIT, Dept Mech Engn, Cambridge, MA 02139 USA
[2] Gradiant Corp, Woburn, MA 01801 USA
[3] King Fahd Univ Petr & Minerals, Dept Mech Engn, Dhahran 31261, Saudi Arabia
关键词
Entropy generation minimization; Mass extraction/injection; Heat and mass exchanger; Bubble column; Energy effectiveness; Enthalpy pinch; HEAT-TRANSFER; ENTROPY GENERATION; PERFORMANCE; EXTRACTION; DESIGN; CONDENSATION; INJECTIONS; WATER;
D O I
10.1016/j.desal.2015.04.021
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Humidification dehumidification (HDH) is a desalination technology that has shown promise in small scale, decentralized applications. Previous studies on the multi-staging of HDH have used fixed-effectiveness models which do not explicitly account for transport processes in the components. However, to fully understand the effect of the variation of the mass flow rate ratio, it is necessary to implement heat and mass transfer models of the HDH system. In this paper, we model an HDH system consisting of a packed-bed humidifier and a multi-tray bubble column dehumidifier. We study the effect of the mass flow rate ratio on the performance of a fixed-size system, and we consider its effect on the entropy generation and the driving forces for heat and mass transfer. In addition, we define a generalized energy effectiveness for heat and mass exchangers. We also implement an air extraction/injection and simulate a wide range of operating conditions. We define criteria for the best system performance, and we study the effect of the distribution of available area between separate stages. We also present a thorough explanation of why the direction of extraction should always be from the humidifier to the dehumidifier. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:125 / 139
页数:15
相关论文
共 39 条
[11]   Optimal operating conditions and configurations for humidification-dehumidification desalination cycles [J].
Mistry, Karan H. ;
Mitsos, Alexander ;
Lienhard, John H. .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2011, 50 (05) :779-789
[12]   Effect of entropy generation on the performance of humidification-dehumidification desalination cycles [J].
Mistry, Karan H. ;
Lienhard, John H. ;
Zubair, Syed M. .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2010, 49 (09) :1837-1847
[13]  
Misty K.H., 2011, ENTROPY, V13
[14]   STUDY ON FORCED CONVECTIVE HEAT TRANSFER IN CURVED PIPES (2ND REPORT TURBULENT REGION) [J].
MORI, Y ;
NAKAYAMA, W .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1967, 10 (01) :37-&
[15]   Solar thermal desalination using the Multiple Effect Humidification (MEH)-method [J].
Mueller-Holst, Hendrik .
Solar Desalination for the 21st Century: A REVIEW OF MODERN TECHNOLOGIES AND RESEARCHES ON DESALINATION COUPLED TO RENEWABLE ENERGIES, 2007, :215-225
[16]  
Muller-Holst H., 2002, THESIS TU BERLIN
[17]  
Narayan G. P., 2014, HUMIDIFICATION DEHUM
[18]  
Narayan G.P., 2012, IDA J, V4, P24
[19]   Bubble Columns for Condensation at High Concentrations of Noncondensable Gas: Heat-Transfer Model and Experiments [J].
Narayan, G. Prakash ;
Sharqawy, Mostafa H. ;
Lam, Steven ;
Das, Sarit K. ;
Lienhard, John H. .
AICHE JOURNAL, 2013, 59 (05) :1780-1790
[20]   Thermal design of the humidification dehumidification desalination system: An experimental investigation [J].
Narayan, G. Prakash ;
St John, Maximus G. ;
Zubair, Syed M. ;
Lienhard, John H., V .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 58 (1-2) :740-748