Highly Sensitive Detection of Cd2+ Using Boron Doped Diamond Electrodes

被引:12
作者
Fierro, Stephane [1 ]
Watanabe, Takeshi [1 ]
Akai, Kazumi [1 ]
Yamanuki, Mikito [2 ]
Einaga, Yasuaki [1 ,3 ]
机构
[1] Keio Univ, Dept Chem, Fac Sci & Technol, Yokohama, Kanagawa 2238522, Japan
[2] HORIBA Ltd, Kyoto 6018510, Japan
[3] JST, CREST, Yokohama, Kanagawa 2238522, Japan
关键词
ATOMIC-ABSORPTION-SPECTROMETRY; ANODIC-STRIPPING VOLTAMMETRY; CADMIUM DETERMINATION; FLUORESCENCE SPECTROMETRY; SAMPLES; REMOVAL; COPPER; FLOWS; METAL; WATER;
D O I
10.1149/2.080111jes
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The electrochemical detection of Cd2+ has been performed by anodic stripping voltammetry on boron doped diamond (BDD) electrodes. A new technique is proposed, which involves adding a known amount of copper to the sample to deposit an amalgam of Cd-Cu on the surface of the BDD electrode. This amalgam is then stripped during voltammetry measurements, allowing the generation of highly accurate calibration curves for Cd detection (r(2) = 0.99) with a lower detection limit of 10 ppb. The conditions that are used for the anodic stripping voltammetry measurements have been optimized to avoid the deposition of cadmium and the appearance of the stripping peak related to copper. Real samples could contain a certain amount of copper, so the influence of small variations of Cu2+ concentration has been investigated and it was found that such variations have no influence on the accuracy of the calibration curve for Cd detection. The influence of other metals that could be dissolved in the sample has also been studied, and it was shown that lead and selenium have a negative influence on the technique. However, this negative interference can be eliminated by increasing the concentration of copper that is introduced in the sample. Furthermore, other species such as boron or chromium have no influence on the anodic stripping voltammetry measurements, so accurate calibration curves for Cd determination could be constructed in the presence of Pb, Se, B and Cr. (C) 2011 The Electrochemical Society. [DOI: 10.1149/2.080111jes] All rights reserved.
引用
收藏
页码:F173 / F178
页数:6
相关论文
共 28 条
  • [1] Cadmium Flows Caused by the Worldwide Production of Primary Zinc Metal
    Achternbosch, Matthias
    Kupsch, Christel
    Sardemann, Gerhard
    Braeutigam, Klaus-Rainer
    [J]. JOURNAL OF INDUSTRIAL ECOLOGY, 2009, 13 (03) : 438 - 454
  • [2] CADMIUM DETERMINATION IN SOIL EXTRACTS BY FURNACE ATOMIC-ABSORPTION
    BAUCELLS, M
    LACORT, G
    ROURA, M
    PASCAL, MD
    FELIPO, MT
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1985, 22 (1-2) : 61 - 70
  • [3] Characteristics of subtractive anodic stripping voltammetry of Pb and Cd at silver and gold electrodes
    Bonfil, Y
    Brand, M
    Kirowa-Eisner, E
    [J]. ANALYTICA CHIMICA ACTA, 2002, 464 (01) : 99 - 114
  • [4] Carlosena A, 1996, FRESEN J ANAL CHEM, V355, P289
  • [5] Environmental contamination from lead, copper and cadmium - Determination using the woodlouse as bioaccumulator and potentiometric stripping analysis for measurement
    Crowther, D
    Rogerson, V
    Cooke, M
    [J]. ANALYTICAL COMMUNICATIONS, 1996, 33 (03): : 93 - 94
  • [7] Preconcentration procedures for trace cadmium determination in natural aqueous systems prior to Zeeman ETAAS
    Cundeva, K
    Stafilov, T
    Pavlovska, G
    Karadjova, I
    Arpadjan, S
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2003, 83 (12) : 1009 - 1019
  • [8] An on-line pre-concentration system for determination of cadmium in drinking water using FAAS
    dos Santos, Walter N. L.
    Costa, Jorge L. O.
    Araujo, Rennan G. O.
    de Jesus, Djane S.
    Costa, Antonio C. S.
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2006, 137 (03) : 1357 - 1361
  • [9] Fierro S., 2011, INT J ELECTROCHEMIST, V2012, P1
  • [10] Friberg L, 1986, HDB TOXICOLOGY METAL, VII, P355