Clinical Value of Absolute Quantification of Myocardial Perfusion With 15O-Water in Coronary Artery Disease

被引:139
作者
Kajander, Sami A. [1 ]
Joutsiniemi, Esa [2 ]
Saraste, Markku [3 ]
Pietila, Mikko [2 ]
Ukkonen, Heikki [2 ]
Saraste, Antti [2 ]
Sipila, Hannu T. [1 ]
Teras, Mika [1 ]
Maki, Maija [3 ]
Airaksinen, Juhani [2 ]
Hartiala, Jaakko [3 ]
Knuuti, Juhani [1 ]
机构
[1] Univ Turku, Turku PET Ctr, FI-20521 Turku, Finland
[2] Univ Turku, Dept Med, FI-20521 Turku, Finland
[3] Univ Turku, Dept Clin Physiol & Nucl Med, FI-20521 Turku, Finland
基金
芬兰科学院;
关键词
cardiac-gated imaging techniques; positron-emission tomography; coronary artery disease; perfusion; FRACTIONAL FLOW RESERVE; BLOOD-FLOW; N-13; AMMONIA; PET; REPRODUCIBILITY; N-13-AMMONIA; ANGIOGRAPHY; MEN;
D O I
10.1161/CIRCIMAGING.110.960732
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The standard interpretation of perfusion imaging is based on the assessment of relative perfusion distribution. The limitations of that approach have been recognized in patients with multivessel disease and endothelial dysfunction. To date, however, no large clinical studies have investigated the value of measuring quantitative blood flow and compared that with relative uptake. Methods and Results-One hundred four patients with moderate (30%-70%) pretest likelihood of coronary artery disease (CAD) underwent PET imaging during adenosine stress using O-15-water and dynamic imaging. Absolute myocardial blood flow was calculated from which both standard relative myocardial perfusion images and images scaled to a known absolute scale were produced. The patients and the regions then were classified as normal or abnormal and compared against the reference of conventional angiography with fractional flow reserve. In patient-based analysis, the positive predictive value, negative predictive value, and accuracy of absolute perfusion in the detection of any obstructive CAD were 86%, 97%, and 92%, respectively, with absolute quantification. The corresponding values with relative analysis were 61%, 83%, and 73%, respectively. In region-based analysis, the receiver operating characteristic curves confirmed that the absolute quantification was superior to relative assessment. In particular, the specificity and positive predictive value were low using just relative differences in flow. Only 9 of 24 patients with 3-vessel disease were correctly assessed using relative analysis. Conclusions-The measurement of myocardial blood flow in absolute terms has a significant impact on the interpretation of myocardial perfusion. As expected, multivessel disease is more accurately detected.
引用
收藏
页码:678 / 684
页数:7
相关论文
共 22 条
  • [1] Long-term clinical outcome after fractional flow reserve-guided percutaneous coronary intervention in patients with multivessel disease
    Berger, A
    Botman, KJ
    MacCarthy, PA
    Wijns, W
    Bartunek, J
    Heyndrickx, GR
    Pijls, NHJ
    De Bruyne, B
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (03) : 438 - 442
  • [2] DIRECT COMPARISON OF [N-13] AMMONIA AND [O-15]WATER ESTIMATES OF PERFUSION WITH QUANTIFICATION OF REGIONAL MYOCARDIAL BLOOD-FLOW BY MICROSPHERES
    BOL, A
    MELIN, JA
    VANOVERSCHELDE, JL
    BAUDHUIN, T
    VOGELAERS, D
    DEPAUW, M
    MICHEL, C
    LUXEN, A
    LABAR, D
    COGNEAU, M
    ROBERT, A
    HEYNDRICKX, GR
    WIJNS, W
    [J]. CIRCULATION, 1993, 87 (02) : 512 - 525
  • [3] EARLY DETECTION OF ABNORMAL CORONARY FLOW RESERVE IN ASYMPTOMATIC MEN AT HIGH-RISK FOR CORONARY-ARTERY DISEASE USING POSITRON EMISSION TOMOGRAPHY
    DAYANIKLI, F
    GRAMBOW, D
    MUZIK, O
    MOSCA, L
    RUBENFIRE, M
    SCHWAIGER, M
    [J]. CIRCULATION, 1994, 90 (02) : 808 - 817
  • [4] Impact of acquisition geometry, image processing, and patient size on lesion detection in whole-body 18F-FDG PET
    El Fakhri, Georges
    Santos, Paula A.
    Badawi, Ramsey D.
    Holdsworth, Clay H.
    Van den Abbeele, Annick D.
    Kijewski, Marie Foley
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (12) : 1951 - 1960
  • [5] Reproducibility and Accuracy of Quantitative Myocardial Blood Flow Assessment with 82Rb PET: Comparison with 13N-Ammonia PET
    El Fakhri, Georges
    Kardan, Arash
    Sitek, Arkadiusz
    Dorbala, Sharmila
    Abi-Hatem, Nathalie
    Lahoud, Youmna
    Fischman, Alan
    Coughlan, Martha
    Yasuda, Tsunehiro
    Di Carli, Marcelo F.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (07) : 1062 - 1071
  • [6] Quantitative myocardial perfusion PET combined with coronary anatomy derived from CT angiography: Validation of a new fusion and visualisation software
    Fricke, Harald
    Elsner, Andreas
    Weise, Reiner
    Bolte, Matthias
    van den Hoff, Joerg
    Burchert, Wolfgang
    Domik, Gitta
    Fricke, Eva
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2009, 19 (03): : 182 - 188
  • [7] Comparison of Positron Emission Tomography Measurement of Adenosine-Stimulated Absolute Myocardial Blood Flow Versus Relative Myocardial Tracer Content for Physiological Assessment of Coronary Artery Stenosis Severity and Location
    Hajjiri, Mohammad M.
    Leavitt, Marcia B.
    Zheng, Hui
    Spooner, Amy E.
    Fischman, Alan J.
    Gewirtz, Henry
    [J]. JACC-CARDIOVASCULAR IMAGING, 2009, 2 (06) : 751 - 758
  • [8] QUANTITATIVE MEASUREMENT OF REGIONAL MYOCARDIAL BLOOD-FLOW IN PATIENTS WITH CORONARY-ARTERY DISEASE BY INTRAVENOUS-INJECTION OF N-13 AMMONIA IN POSITRON EMISSION TOMOGRAPHY
    HARA, T
    MICHIHATA, T
    YOKOI, F
    SAKAMOTO, S
    MASUOKA, T
    LIO, M
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1990, 16 (4-6): : 231 - 235
  • [9] Cardiac Positron Emission Tomography/Computed Tomography Imaging Accurately Detects Anatomically and Functionally Significant Coronary Artery Disease
    Kajander, S.
    Joutsiniemi, E.
    Saraste, M.
    Pietila, M.
    Ukkonen, H.
    Saraste, A.
    Sipila, H. T.
    Teras, M.
    Maki, M.
    Airaksinen, J.
    Hartiala, J.
    Knuuti, J.
    [J]. CIRCULATION, 2010, 122 (06) : 603 - 613
  • [10] Low radiation dose imaging of myocardial perfusion and coronary angiography with a hybrid PET/CT scanner
    Kajander, S.
    Ukkonen, H.
    Sipila, H.
    Teras, M.
    Knuuti, J.
    [J]. CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2009, 29 (01) : 81 - 88