The development of a control method for a total artificial heart using mixed venous oxygen saturation

被引:11
作者
Nakamura, M
Masuzawa, T
Tatsumi, E
Taenaka, Y
Nakamura, T
Zhang, B
Nakatani, T
Takano, H
Ohno, T
机构
[1] Natl Cardiovasc Ctr, Res Inst, Dept Artificial Organs, Osaka 5658565, Japan
[2] Tokyo Denki Univ, Tokyo 101, Japan
关键词
total artificial heart; mixed venous oxygen saturation; cardiac output; control; exercise;
D O I
10.1046/j.1525-1594.1999.06314.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
For physiological control of a total artificial heart (TAH), applying mixed venous oxygen saturation (Svo(2)) as a parameter for TAH control is a promising approach regarding sensitivity to the recipient's oxygen demand and the practical possibility of continuous monitoring using near infrared rays through transparent blood pump housings. To develop a control method for the TAH using Svo(2), the relationship between Svo(2) and cardiac output (CO) was investigated in a normal calf, and a control algorithm was developed based on this correlation. Then the feasibility of this method (Svo(2) mode) was evaluated in a calf implanted with a pneumatic TAH and compared with the fixed drive control mode (fixed mode) in which the drive parameters were unchanged. The calf performed a graded exercise test in both modes. The CO was effectively increased from 7.3 to 13.0 L/min in the Svo(2) mode, and the capacity for exercise was augmented compared to the fixed mode. We conclude that this Svo(2) mode is feasible and may be effectively applied in TAH control.
引用
收藏
页码:235 / 241
页数:7
相关论文
共 14 条
[1]   Control of the artificial heart [J].
Allen, GS ;
Murray, KD ;
Olsen, DB .
ASAIO JOURNAL, 1996, 42 (06) :932-937
[2]   REGULATION OF PNEUMATIC TOTAL ARTIFICIAL-HEART FUNCTION - A REVIEW [J].
DELEUZE, PH ;
RIEBMAN, JB ;
DEPAULIS, R ;
OLSEN, DB ;
LOISANCE, DY .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1988, 11 (03) :147-152
[3]   LONG-TERM CLINICAL-PERFORMANCE OF A CENTRAL VENOUS OXYGEN-SATURATION SENSOR FOR RATE-ADAPTIVE CARDIAC PACING [J].
FAERESTRAND, S ;
OHM, OJ ;
STANGELAND, L ;
HEYNEN, H ;
MOORE, A .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (08) :1355-1372
[4]   INVIVO COMPARISON OF 2 MIXED VENOUS SATURATION CATHETERS [J].
GETTINGER, A ;
DETRAGLIA, MC ;
GLASS, DD .
ANESTHESIOLOGY, 1987, 66 (03) :373-375
[5]  
Nakamura M, 1997, ASAIO J, V43, pM663
[6]  
Ohno T, 1997, ASAIO J, V43, pM677
[7]  
OHNO T, 1998, JJME S, V36, P572
[8]  
SCHIMA H, 1989, ARTIF ORGANS, V13, P545
[9]   INVIVO AND INVITRO STUDIES OF A CHRONIC OXYGEN-SATURATION SENSOR [J].
SEIFERT, GP ;
MOORE, AA ;
GRAVES, KL ;
LAHTINEN, SP .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (10) :1514-1527
[10]  
STANLEY TH, 1973, T AM SOC ART INT ORG, V19, P258