An Amperometric Biosensor for Glucose Determination Prepared from Glucose Oxidase Immobilized in Polyaniline-Polyvinylsulfonate Film

被引:55
作者
Arslan, Fatma [1 ]
Ustabas, Selvin [2 ]
Arslan, Halit [1 ]
机构
[1] Gazi Univ, Dept Chem, Fac Sci, TR-06500 Ankara, Turkey
[2] Gazi Univ, Inst Sci, Dept Chem, TR-06500 Ankara, Turkey
关键词
glucose; biosensor; amperometry; polyaniline; polyvinylsulphonate; ELECTRODE;
D O I
10.3390/s110808152
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a novel amperometric glucose biosensor with immobilization of glucose oxidase on electrochemically polymerized polyaniline-polyvinylsulphonate (Pani-Pvs) films has been accomplished via the entrapment technique. Electropolymerization of aniline on the Pt surface of the Pt electrode was carried out at constant potential (0.75 V, vs. Ag/AgCl) using an electrochemical cell containing aniline and polyvinylsulphonate. Firstly, the optimum working conditions for preparing polyaniline-polyvinylsulfonate films were investigated. Determination of glucose was carried out by the oxidation of enzymatically produced H2O2 at 0.4 V vs. Ag/AgCl. The effects of pH and temperature were investigated and the optimum pH value was found to be 7.5. The storage stability and operational stability of the enzyme electrode were also studied. The results show that 75% of the response current was retained after 16 activity assays. The prepared glucose biosensor retained 80.6% of initial activity after 40 days when stored in 0.1 M phosphate buffer solution at 4 degrees C.
引用
收藏
页码:8152 / 8163
页数:12
相关论文
共 16 条
[1]  
BARTLETT PN, 1993, J ELECTROANAL CHEM, V362, P1
[2]   ELECTROCONDUCTING CONJUGATED POLYMERS - NEW SENSITIVE MATRICES TO BUILD UP CHEMICAL OR ELECTROCHEMICAL SENSORS - A REVIEW [J].
BIDAN, G .
SENSORS AND ACTUATORS B-CHEMICAL, 1992, 6 (1-3) :45-56
[3]   A noninterference polypyrrole glucose biosensor [J].
Chen, Cheng ;
Jiang, Yan ;
Kan, Jinqing .
BIOSENSORS & BIOELECTRONICS, 2006, 22 (05) :639-643
[4]   Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review [J].
Cosnier, S .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (05) :443-456
[5]  
Gaikwad PD, 2007, INT J ELECTROCHEM SC, V2, P488
[6]  
GAIKWAD PD, 2005, MICROWAVES OPTOELECT, P450
[7]  
Gros P, 2000, ELECTROCHIM ACTA, V46, P643
[8]  
Norouzi P, 2010, INT J ELECTROCHEM SC, V5, P1213
[9]   Amperometric glucose biosensor based on in situ electropolymerized polyaniline/poly(acrylonitrile-co-acrylic acid) composite film [J].
Shan, Dan ;
Wang, Shanxia ;
He, Yuanyuan ;
Xue, Huaiguo .
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2008, 28 (02) :213-217
[10]   Glucose biosensor based on polyaniline synthesized in ionic liquid [J].
Shi, Qiaofang ;
Wang, Peng ;
Jiang, Yan ;
Kan, Jinqing .
BIOCATALYSIS AND BIOTRANSFORMATION, 2009, 27 (01) :54-59