Guided bone regeneration around titanium plasma-sprayed, acid-etched, and hydroxyapatite-coated implants in the canine model

被引:24
|
作者
Conner, KA
Sabatini, R
Mealey, BL
Takacs, VJ
Mills, MP
Cochran, DL
机构
[1] Dept Periodont, Misawa, Japan
[2] Wilford Hall USAF Med Ctr, Dept Periodont, Lackland AFB, TX USA
[3] Univ Texas, Hlth Sci Ctr, Dept Periodont, San Antonio, TX 78284 USA
关键词
animal studies; dental implants; follow-up studies; guided bone regeneration; hydroxyapatite/therapeutic use; membranes; artificial; barrier; polytetrafluoroethylene/therapeutic use; titanium;
D O I
10.1902/jop.2003.74.5.658
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: Endosseous dental implants with rough surfaces have been designed to improve early healing, especially in areas of poor bone or insufficient bone quantity. The aim of this study was to histomorphometrically assess the bone-to-implant contact on 3 different rough-surfaced implants following guided bone regeneration. Methods: Mandibular premolars and first molars were extracted in 12 dogs, and healing was allowed for 6 months. Six implant osteotomy sites were prepared, 3 per side, followed by the creation of 7.3 mm wide by 5 mm deep surgical defects in the coronal section of the osteotomy sites. Ten-mm long titanium screw-type implants with titanium plasma-sprayed (TPS), hydroxyapatite-coated (HA), or acid-etched (AE) surfaces were placed; the surrounding defects were filled with canine demineralized freeze-dried bone allograft; implants/grafts were covered with expanded polytetrafluoroethylene membranes; and the tissue was closed. Following a healing period of 4 months, the animals were sacrificed and mandibular blocks were harvested for histomorphometric analysis. Results: The mean percentage of bone-to-implant contact in the defect and non-defect areas for the different implant surfaces was: AE 16.24% defect, and 28.78% non-defect; TPS 25.08% defect, and 16.96% non-defect; and HA 48.25% defect and 26.60% non-defect. Within the defect, the mean difference in the bone-to-implant contact was significant for HA compared to TPS (P <0.0001) and HA versus AE (P <0.0001); TPS versus AE was not significant (P = 0.063). In the non-defect areas, the mean difference in the bone-to-implant contact was significant for AE versus TPS (P = 0.010); all other comparisons were not significant. There were 18 membrane exposures in the 72 implant sites. Data were analyzed again to assess the impact of membrane complications. Using a 1-way analysis of variance, the bone-to-implant contact was compared between the sites with and without membrane complications. No significant differences were seen in the defect areas or in the non-defect areas between the sites with and without membrane complications. Conclusion: In this study, the bone-to-implant contact in regenerated bone was greatest when an HA-coated implant was used.
引用
收藏
页码:658 / 668
页数:11
相关论文
共 50 条
  • [1] DEGRADATION POTENTIAL OF PLASMA-SPRAYED HYDROXYAPATITE-COATED TITANIUM IMPLANTS
    PASCHALIS, EP
    ZHAO, Q
    TUCKER, BE
    MUKHOPADHAYAY, S
    BEARCROFT, JA
    BEALS, NB
    SPECTOR, M
    NANCOLLAS, GH
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (12): : 1499 - 1505
  • [2] A 5-year comparison of hydroxyapatite-coated titanium plasma-sprayed and titanium plasma-sprayed cylinder dental implants
    Jones, JD
    Lupori, J
    Van Sickels, JE
    Gardner, W
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1999, 87 (06): : 649 - 652
  • [3] Clinical evaluation of hydroxyapatite-coated titanium plasma-sprayed and titanium plasma-sprayed cylinder dental implants - A preliminary report
    Jones, JD
    Saigusa, M
    VanSickels, JE
    Tiner, BD
    Gardner, WA
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1997, 84 (02): : 137 - 141
  • [4] Physicochemical study of plasma-sprayed hydroxyapatite-coated implants in humans
    MacDonald, DE
    Betts, F
    Stranick, M
    Doty, S
    Boskey, AL
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2001, 54 (04): : 480 - 490
  • [5] Evaluation of titanium plasma-sprayed and plasma-sprayed hydroxyapatite implants in vivo
    Ong, JL
    Carnes, DL
    Bessho, K
    BIOMATERIALS, 2004, 25 (19) : 4601 - 4606
  • [6] TISSUE INTERFACES TO PURE TITANIUM, TITANIUM-PLASMA-SPRAYED AND HYDROXYAPATITE-COATED IMPLANTS
    SCHUPBACH, P
    HURZELER, M
    QUINONES, C
    CAFFESSE, R
    JOURNAL OF DENTAL RESEARCH, 1995, 74 : 21 - 21
  • [7] Histologic and histomorphometric comparison of immediately placed hydroxyapatite-coated and titanium plasma-sprayed implants: A pilot study in dogs
    Karabuda, C
    Sandalli, P
    Yalcin, S
    Steflik, DE
    Parr, GR
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1999, 14 (04) : 510 - 515
  • [8] Effects of guided bone regeneration around commercially pure titanium and hydroxyapatite-coated dental implants .1. Radiographic analysis
    Stentz, WC
    Mealey, BL
    Nummikoski, PV
    Gunsolley, JC
    Waldrop, TC
    JOURNAL OF PERIODONTOLOGY, 1997, 68 (03) : 199 - 208
  • [9] Effects of guided bone regeneration around commercially pure titanium and hydroxyapatite-coated dental implants .2. Histologic analysis
    Stentz, WC
    Mealey, BL
    Gunsolley, JC
    Waldrop, TC
    JOURNAL OF PERIODONTOLOGY, 1997, 68 (10) : 933 - 949
  • [10] Survival and success of sandblasted, large-grit, acid-etched and titanium plasma-sprayed implants: A retrospective study
    Arlin, Murray L.
    JOURNAL OF THE CANADIAN DENTAL ASSOCIATION, 2007, 73 (09): : 821 - +