Accuracy of CT-guided percutaneous core needle biopsy for assessment of pediatric musculoskeletal lesions

被引:27
|
作者
Hryhorczuk, Anastasia L. [1 ]
Strouse, Peter J. [1 ]
Biermann, J. Sybil [2 ]
机构
[1] Univ Michigan, Dept Radiol, CS Mott Childrens Hosp, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Orthopaed Surg, Ann Arbor, MI 48109 USA
关键词
CT; Musculoskeletal; Biopsy; Interventional; Children; EXTREMITY COMPARTMENTAL ANATOMY; CLINICAL-RELEVANCE; BONE-TUMORS;
D O I
10.1007/s00247-010-1970-6
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
CT-guided percutaneous core needle biopsy has been shown in adults to be an effective diagnostic tool for a large number of musculoskeletal malignancies. To characterize our experience with CT-guided percutaneous core needle biopsy of pediatric bone lesions and determine its utility in diagnosing pediatric osseous lesions, in a population where such lesions are commonly benign. From 2000 to 2009, 61 children underwent 63 CT-guided percutaneous biopsies. Radiological, pathological and clinical records were reviewed. Fourteen biopsies (22%) were performed on malignant lesions, while 49 biopsies (78%) were performed on benign lesions. Forty-nine of the 63 biopsies (78%) were adequate; these children underwent no further tissue sampling. Fourteen of the 63 biopsies (22%) were inadequate or non-conclusive. Of these patients, 12 underwent open biopsy. Retrospective analysis of percutaneous biopsies in these patients demonstrates that 9/12 provided clinically relevant information, and 4/12 patients received final diagnoses that confirmed initial core biopsy findings. No malignancies were diagnosed as benign on percutaneous biopsy. Overall, percutaneous core needle biopsy provided accurate diagnostic information in 84% (53/63) of biopsies. Our results demonstrate that CT-guided percutaneous biopsy is safe and beneficial in children. This study supports the use of CT-guided percutaneous core needle biopsy for primary diagnosis of pediatric bone lesions.
引用
收藏
页码:848 / 857
页数:10
相关论文
共 50 条
  • [21] Accuracy of CT-guided biopsies in 359 patients with musculoskeletal lesions
    Hau, MA
    Kim, JI
    Kattapuram, S
    Hornicek, FJ
    Rosenberg, AE
    Gebhardt, MC
    Mankin, HJ
    SKELETAL RADIOLOGY, 2002, 31 (06) : 349 - 353
  • [22] CT-guided percutaneous core biopsy. Effective accuracy, diagnostic utility and effective costs.
    Wutke, R
    Schmid, A
    Fellner, F
    Horbach, T
    Kastl, S
    Papadopoulos, T
    Hohenberger, W
    Bautz, W
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (11): : 1025 - 1033
  • [23] Initial Experience in CT-Guided Percutaneous Transthoracic Needle Biopsy of Lung Lesions Performed by a Pulmonologist
    Ahn, June Hong
    Jang, Jong Geol
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (06)
  • [24] Percutaneous CT-guided vertebral bone biopsy in children
    Ballah, Deddeh
    Nijs, Els
    Keller, Marc S.
    Zhu, Xiaowei
    Krishnamurthy, Ganesh
    Cahill, Anne Marie
    PEDIATRIC RADIOLOGY, 2013, 43 (05) : 582 - 588
  • [25] Percutaneous CT-guided vertebral bone biopsy in children
    Deddeh Ballah
    Els Nijs
    Marc S. Keller
    Xiaowei Zhu
    Ganesh Krishnamurthy
    Anne Marie Cahill
    Pediatric Radiology, 2013, 43 : 582 - 588
  • [26] Flat detector cone-beam CT-guided percutaneous needle biopsy of mediastinal lesions: preliminary experience
    Jiao, Dechao
    Huang, Kai
    Wu, Gang
    Wang, Yanli
    Han, Xinwei
    RADIOLOGIA MEDICA, 2016, 121 (10): : 769 - 779
  • [27] Accuracy of CT-guided transthoracic needle biopsy of lung lesions: Factors affecting diagnostic yield
    Priola A.M.
    Priola S.M.
    Cataldi A.
    Errico L.
    Di Franco M.
    Campisi P.
    Molinaro L.
    Marci V.
    Novello S.
    Fava C.
    La radiologia medica, 2007, 112 (8) : 1142 - 1159
  • [28] CT-guided percutaneous fine needle biopsy of solid kidney tumours.
    Barriol, D
    Lechevallier, E
    Andre, M
    Daniel, L
    Ortega, JC
    Rosi, D
    Coulange, C
    PROGRES EN UROLOGIE, 2000, 10 (06): : 1145 - 1151
  • [29] Flat detector cone-beam CT-guided percutaneous needle biopsy of mediastinal lesions: preliminary experience
    Dechao Jiao
    Kai Huang
    Gang Wu
    Yanli Wang
    Xinwei Han
    La radiologia medica, 2016, 121 : 769 - 779
  • [30] Accuracy of CT-guided transthoracic needle biopsy of lung lesions: factors affecting diagnostic yield
    Priola, A. M.
    Priola, S. M.
    Cataldi, A.
    Errico, L.
    Di Franco, M.
    Campisi, P.
    Molinaro, L.
    Marci, V.
    Novello, S.
    Fava, C.
    RADIOLOGIA MEDICA, 2007, 112 (08): : 1142 - 1159