Impact of correcting the 2D PISA method on the quantification of functional tricuspid regurgitation severity

被引:25
|
作者
Tomaselli, Michele [1 ,2 ]
Badano, Luigi P. [1 ,2 ]
Mene, Roberto [1 ,2 ]
Gavazzoni, Mara [1 ]
Heilbron, Francesca [1 ,2 ]
Radu, Noela [3 ]
Caravita, Sergio [2 ,4 ]
Baratto, Claudia [1 ]
Oliverio, Giorgio [1 ]
Florescu, Diana R. [2 ,5 ]
Parati, Gianfranco [2 ]
Muraru, Denisa [1 ,2 ]
机构
[1] Univ Milano Bicocca, Dept Med & Surg, Milan, Italy
[2] IRCCS, Dept Cardiol, Ist Auxol Italiano, Ple Brescia 20, I-20149 Milan, Italy
[3] Carol Davila Univ Med & Pharm, Bucharest, Romania
[4] Univ Bergamo, Dept Management Informat & Prod Engn, Dalmine, Italy
[5] Univ Med & Pharm Craiova, Craiova, Romania
关键词
Doppler echocardiography; three-dimensional echocardiography; functional tricuspid regurgitation; severity grading; quantitation; PISA method; effective regurgitant orifice area; regurgitant volume; regurgitant fraction; PROXIMAL FLOW CONVERGENCE; 3-DIMENSIONAL ECHOCARDIOGRAPHY; MAGNETIC-RESONANCE; VENTRICULAR VOLUMES; AMERICAN SOCIETY; RECOMMENDATIONS; ORIFICE; VALVE; VALIDATION; ACCURACY;
D O I
10.1093/ehjci/jeac104
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims In functional tricuspid regurgitation (FTR) patients, tricuspid leaflet tethering and relatively low jet velocity could result in proximal flow geometry distortions that lead to underestimation of TR. Application of correction factors on two-dimensional (2D) proximal isovelocity surface area (PISA) equation may increase its reliability. This study sought to evaluate the impact of the corrected 2D PISA method in quantifying FTR severity. Methods and results In 102 patients with FTR, we compared both conventional and corrected 2D PISA measurements of effective regurgitant orifice area [EROA vs. corrected (EROA(c))] and regurgitant volume (RegVol vs. RegVol(c)) with those obtained by volumetric method (VM) using three-dimensional echocardiography (3DE), as reference. Both EROA(c) and RegVol(c) were larger than EROA (0.29 +/- 0.26 vs. 0.22 +/- 0.21 cm(2); P < 0.001) and RegVol (24.5 +/- 20 vs. 18.5 +/- 14.25 mL; P < 0.001), respectively. Compared with VM, both EROA(c) and RegVol(c) resulted more accurate than EROA [bias = -0.04 cm(2), limits of agreement (LOA) +/- 0.02 cm(2) vs. bias = -0.15 cm(2), LOA +/- 0.31 cm(2)] and RegVol (bias = -3.29 mL, LOA +/- 2.19 mL vs. bias = -10.9 mL, LOA +/- 13.5 mL). Using EROA(c) and RegVol(c), 37% of patients were reclassified in higher grades of FTR severity. Corrected 2D PISA method led to a higher concordance of TR severity grade with the VM method (kappa = 0.84 vs. kappa = 0.33 for uncorrected PISA, P < 0.001). Conclusion Compared with VM by 3DE, the conventional PISA underestimated FTR severity in about 50% of patients. Correction for TV leaflets tethering angle and lower velocity of FTR jet improved 2D PISA accuracy and reclassified more than one-third of the patients.
引用
收藏
页码:1459 / 1470
页数:12
相关论文
共 50 条
  • [41] EasyPISA: Automatic Integrated PISA Measurements of Mitral Regurgitation From 2-D Color-Doppler Using Deep Learning
    Wifstad, Sigurd Vangen
    Kildahl, Henrik Agerup
    Holte, Espen
    Berg, Erik Andreas Rye
    Grenne, Bj(rnar
    Salvesen, Oyvind
    Dalen, Havardvard
    Lovstakken, Lasse
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2024, 50 (11) : 1628 - 1637
  • [42] Towards deep learning methods for quantification of the right ventricle using 2D echocardiography
    Kampaktsis, Polydoros N.
    Moustakidis, Serafeim
    Siasos, Gerasimos
    Vavuranakis, Manolis
    Lebehn, Mark
    FUTURE CARDIOLOGY, 2024, 20 (7-8) : 339 - 341
  • [43] Study on 2D arbitrary geometry coupling resonance method
    He, Lei
    Wu, Hongchun
    Cao, Liangzhi
    Hedongli Gongcheng/Nuclear Power Engineering, 2014, 35 (06): : 1 - 5
  • [44] Intraoperative 2D and 3D transoesophageal echocardiographic predictors of aortic regurgitation after transcatheter aortic valve implantation
    Gripari, Paola
    Ewe, See Hooi
    Fusini, Laura
    Muratori, Manuela
    Ng, Arnold C. T.
    Cefalu, Claudia
    Delgado, Victoria
    Schalij, Martin J.
    Bax, Jeroen J.
    Marsan, Nina Ajmone
    Tamborini, Gloria
    Pepi, Mauro
    HEART, 2012, 98 (16) : 1229 - 1236
  • [45] Vena contracta area for severity grading in functional and degenerativemitral regurgitation: a transoesophageal 3D colour Doppler analysis in 500 patients
    Goebel, Bjoern
    Heck, Roland
    Hamadanchi, Ali
    Otto, Sylvia
    Doenst, Torsten
    Jung, Christian
    Lauten, Alexander
    Figulla, Hans R.
    Schulze, P. Christian
    Poerner, Tudor C.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2018, 19 (06) : 639 - 646
  • [46] Impact of the Born approximation on the estimation error in 2D inverse scattering
    Diong, M. L.
    Roueff, A.
    Lasaygues, P.
    Litman, A.
    INVERSE PROBLEMS, 2016, 32 (06)
  • [47] Automated Quantification of Simple and Complex Aortic Flow Using 2D Phase Contrast MRI
    Li, Rui
    Assadi, Hosamadin S.
    Zhao, Xiaodan
    Matthews, Gareth
    Mehmood, Zia
    Grafton-Clarke, Ciaran
    Limbachia, Vaishali
    Hall, Rimma
    Kasmai, Bahman
    Hughes, Marina
    Thampi, Kurian
    Hewson, David
    Stamatelatou, Marianna
    Swoboda, Peter P.
    Swift, Andrew J.
    Alabed, Samer
    Nair, Sunil
    Spohr, Hilmar
    Curtin, John
    Gurung-Koney, Yashoda
    van der Geest, Rob J.
    Vassiliou, Vassilios S.
    Zhong, Liang
    Garg, Pankaj
    MEDICINA-LITHUANIA, 2024, 60 (10):
  • [48] Evaluation of mitral regurgitation by an integrated 2D echocardiographic approach in patients undergoing transcatheter aortic valve replacement
    Jansen, R.
    Wind, A. M.
    Cramer, M. J.
    Nijhoff, F.
    Agostoni, P.
    Ramjankhan, F. Z.
    Suyker, W. J.
    Stella, P. R.
    Chamuleau, S. A. J.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2018, 34 (08) : 1193 - 1204
  • [49] Quantification of Functional Mitral Regurgitation by Real-Time 3D Echocardiography Comparison With 3D Velocity-Encoded Cardiac Magnetic Resonance
    Marsan, Nina Ajmone
    Westenberg, Jos J. M.
    Ypenburg, Claudia
    Delgado, Victoria
    van Bommel, Rutger J.
    Roes, Stijntje D.
    Nucifora, Gaetano
    van der Geest, Rob J.
    de Roos, Albert
    Reiber, Johan C.
    Schalij, Martin J.
    Bax, Jeroen J.
    JACC-CARDIOVASCULAR IMAGING, 2009, 2 (11) : 1245 - 1252
  • [50] Progress in the Development of a 2D Feature Selective Validation (FSV) Method
    Orlandi, A.
    Antonini, G.
    Polisini, C.
    Duffy, A.
    Sasse, H.
    2008 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, VOLS 1-3, 2008, : 818 - +