Determination of 28 selected elements in textiles by axially viewed inductively coupled plasma optical emission spectrometry

被引:25
|
作者
Rezic, Iva [1 ,2 ]
Zeiner, Michaela [2 ]
Steffan, Ilse [2 ]
机构
[1] Univ Zagreb, Fac Text Technol, Dept Appl Chem, Analyt Chem Lab, Zagreb 10000, Croatia
[2] Univ Vienna, Fac Chem, Dept Analyt & Food Chem, A-1010 Vienna, Austria
关键词
Validation; Optimization; ICP-OES; Textile; Microwave assisted digestion; ENVIRONMENTAL MATERIALS; WHITEWASHED DENIM; PLANT-SAMPLES; METAL CONTENT; INTERFERENCES; ACCUMULATION;
D O I
10.1016/j.talanta.2010.10.031
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, robust and reliable analytical procedure for the determination of 28 selected elements, namely Al, As, Ba, Be, Bi, Ca, Cd, Co, Cr, Cu, Fe, K, Ng, Mg, Mn, Mo, Na, Ni, Pb, Sc, Si, Se, Sn, Sm, Sr, TI, V, and Zn in textile materials by inductively coupled plasma optical emission spectrometry (ICP-OES) after microwave digestion of samples was optimized and validated in this work. The total amount of elements present in textile samples was determined after microwave digestion of materials in 7 mol/L nitric acid within the optimal working program: 5 min at 150 degrees C (power 250W), 15 min 180 degrees C (300W) and 20 min at the maximum temperature of 200 degrees C (350W). For the quality control reasons, which were ascertained by analysis of the certified cotton trace elements reference material IAEA-V9, the ICP-OES method was optimized through several parameters: by comparing Meinhard and Gemcone Low Flow nebulizers efficiency, ranging nebulizer gas flows from 0.6 to 1.0 L/min, ranging sample flows from 0.8 to 1.2 mL/min, testing RF power from 1200 to 1400W, detecting data acquisition time (read time) from 0 to 527s, ranging washing (delay) time from 0 to 408s, as well as by checking the occurring interferences for the optimal line selection. Validation included determination of linearity, selectivity, accuracy, reproducibility, precision and limits of detection calculated for all 28 selected elements of interest. The developed analytical procedure was successfully applied on textile fibers (cotton, flax and hemp) as well as on standard knitted textile sample materials (cotton and wool). (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:865 / 871
页数:7
相关论文
共 50 条
  • [21] Improvement in the single and simultaneous generation of As, Bi, Sb and Se hydrides using a vapor generation accessory (VGA) coupled to axially viewed inductively coupled plasma optical emission spectrometry (ICP OES)
    Welna, Maja
    Szymczycha-Madeja, Anna
    Pohl, Pawel
    ANALYTICAL METHODS, 2017, 9 (05) : 871 - 880
  • [23] Direct analysis of deodorants for determination of metals by inductively coupled plasma optical emission spectrometry
    Oliveira Correia da Costa, Wiviane Kassia
    da Silva, Caroline Santos
    Dagnone Figueiredo, Jose Fernando
    Nobrega, Joaquim Araujo
    Silveira Paim, Ana Paula
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 155 : 247 - 252
  • [24] DETERMINATION OF TRACE AND MAJOR ELEMENTS IN WATER ON OIL PALM PLANTATIONS BY INDUCTIVELY COUPLED PLASMA-OPTICAL EMISSION SPECTROMETRY
    Olafisoye, Bola O.
    Fatoki, Olalekan O.
    Oguntibeju, Oluwafemi O.
    Osibote, Adelaja O.
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2014, 42 (06) : 652 - 666
  • [25] Determination of inorganic contaminants in glue by inductively coupled argon plasma optical emission spectrometry
    Matoso, Erika
    Cadore, Solange
    TALANTA, 2011, 84 (02) : 335 - 340
  • [26] Determination of trace elements in biodiesel and vegetable oil by inductively coupled plasma optical emission spectrometry following alcohol dilution
    Chaves, Eduardo S.
    de Loos-Vollebregt, Margaretha T. C.
    Curtius, Adilson J.
    Vanhaecke, Frank
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (9-10) : 733 - 739
  • [27] Determination of minerals and trace elements in cheese by inductively-coupled plasma optical emission spectrometry after partial digestion
    Kira, Carmen Silvia
    Maihara, Vera Akiko
    CIENCIA E TECNOLOGIA DE ALIMENTOS, 2007, 27 (03): : 446 - 450
  • [28] Lead determination by microwave-assisted inductively coupled plasma optical emission Spectrometry for RoHS compliance
    Hua, L.
    Wu, Y. P.
    An, B.
    Wu, F. S.
    HDP'07: PROCEEDINGS OF THE 2007 INTERNATIONAL SYMPOSIUM ON HIGH DENSITY PACKAGING AND MICROSYSTEM INTEGRATION, 2007, : 250 - +
  • [29] Simultaneous determination of As and Sb in soil using hydride generation capacitively coupled plasma microtorch optical emission spectrometry - comparison with inductively coupled plasma optical emission spectrometry
    Frentiu, Tiberiu
    Butaciu, Sinziana
    Ponta, Michaela
    Darvasi, Eugen
    Senila, Marin
    Petreus, Dorin
    Frentiu, Maria
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (10) : 1880 - 1888
  • [30] Multielemental inductively coupled plasma optical emission spectrometry analysis of nickeliferous minerals
    Abad-Pena, Elizabet
    Teresa Larrea-Marin, Maria
    Edelia Villanueva-Tagle, Margarita
    Simeon Pomares-Alfonso, Mario
    TALANTA, 2014, 124 : 79 - 88