Assessment of brain shift related to deep brain stimulation surgery

被引:141
作者
Khan, Muhammad Faisal [1 ]
Mewes, Klaus [3 ]
Gross, Robert E. [4 ]
Skrinjar, Oskar [1 ,2 ]
机构
[1] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
[2] Georgia Inst Technol, Dept Biomed Engn, Atlanta, GA 30332 USA
[3] Emory Univ, Sch Med, Dept Neurol, Atlanta, GA 30322 USA
[4] Emory Univ, Sch Med, Dept Neurol Surg, Atlanta, GA 30322 USA
关键词
brain shift; brain deformation; deep brain stimulation; image registration;
D O I
10.1159/000108588
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Deep brain stimulation (DBS) surgery can significantly improve the quality of life for patients suffering from movement disorders, but the success of the procedure depends on the implantation accuracy of the DBS electrode array. Pre-operative surgical planning and navigation are based on the assumption that the brain tissue is rigid between the time of the acquisition of the pre-operative image set and the time of surgery. A shift of deep brain structures by only a few millimeters can potentially increase the number of required microelectrode and/or macroelectrode tracks and decrease implantation accuracy. We studied 25 subjects that underwent DBS surgery and analyzed brain shift between pre- operative and post-operative 3D MRI scans. Brain shift of up to 4 mm was observed in deep brain structures. On average, the recorded shift was in the direction of gravity, with deeper structures experiencing smaller shift than more superficial structures. The main conclusion of the study is that the brain shift is comparable to the size of the targets in deep brain stimulation surgery and should not be ignored. Techniques that minimize the amount of brain shift may therefore lead to increased accuracy of DBS lead implantation. Copyright (C) 2007 S. Karger AG, Basel.
引用
收藏
页码:44 / 53
页数:10
相关论文
共 29 条
[1]   Targeting the subthalamic nucleus [J].
Aziz, TZ ;
Nandi, D ;
Parkin, S ;
Liu, X ;
Giladi, N ;
Bain, P ;
Gregory, RG ;
Joint, C ;
Scott, RB ;
Stein, JF .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2001, 77 (1-4) :87-90
[3]  
Bucholz RD, 1997, LECT NOTES COMPUT SC, V1205, P459, DOI 10.1007/BFb0029268
[4]   Intraoperative ultrasound for guidance and tissue shift correction in image-guided neurosurgery [J].
Comeau, RM ;
Sadikot, AF ;
Fenster, A ;
Peters, TM .
MEDICAL PHYSICS, 2000, 27 (04) :787-800
[5]  
Edwards P J, 1998, Med Image Anal, V2, P355, DOI 10.1016/S1361-8415(98)80016-9
[6]   The distribution of target registration error in rigid-body point-based registration [J].
Fitzpatrick, JM ;
West, JB .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (09) :917-927
[7]   Electrophysiological mapping for the implantation of deep brain stimulators for Parkinson's disease and tremor [J].
Gross, Robert E. ;
Krack, Paul ;
Rodriguez-Oroz, Maria C. ;
Rezai, Ali R. ;
Benabid, Alim-Louis .
MOVEMENT DISORDERS, 2006, 21 :S259-S283
[8]  
HATA N, 1999, VOLUMETRIC OPTICAL F, P928
[9]  
HILL DLG, 1999, ASSESSMENT INTRAOPER, P910
[10]  
HILL DLG, 1997, ESTIMATION INTRAOPER, P449