Experimental investigation on the performance of a transcritical CO2 heat pump with multi-ejector expansion system

被引:55
作者
Boccardi, G. [1 ]
Botticella, F. [2 ]
Lillo, G. [3 ]
Mastrullo, R. [3 ]
Mauro, A. W. [3 ]
Trinchieri, R. [1 ]
机构
[1] ENEA, Energy Dept Prod Convers & Use Energy Div, Lab Dev Chem Proc & Thermofluidynam, Via Anguillarese 301, I-00123 Rome, Italy
[2] Univ Sannio, Dept Engn DING, Corso Garibaldi 107, I-82100 Benevento, Italy
[3] Federico II Univ Naples, Dept Ind Engn, Ple Tecchio 80, I-80125 Naples, Italy
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2017年 / 82卷
关键词
Carbon dioxide; Ejector; Transcritical cycle; Heat pump; Space heating; REFRIGERATION CYCLE; 2-PHASE EJECTOR; R744; GEOMETRY;
D O I
10.1016/j.ijrefrig.2017.06.013
中图分类号
O414.1 [热力学];
学科分类号
摘要
Carbon dioxide is becoming an interesting option also for HVAC heating appliances due to its eco-friendly characteristics. The incurrence of transcritical cycles makes the use of ejectors attractive to improve performance. Part load conditions and varied ambient temperatures imply the use of variable geometry systems of appropriate design to keep their efficiency high. This paper investigates experimentally amulti-ejector air-to-water CO2 heat pump for heating needs, measuring the performance of the system and of each component under partial and full load conditions. A sensitivity analysis was run varying, separately or in a combined way, the following parameters or operating conditions: ejector area ratio in a range of 33.1-86.6%; compressor frequency in the range of 30-60 Hz; ambient temperature in the range of -15-12 degrees C according to the standard UNI EN 14511/2011. The results show the possibility to reach an optimum of the COP by varying the ejector area, once the other parameters are fixed, as a consequence of the ejector regulation on the pressures at the inlet and outlet of the compressor. (C) 2017 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:389 / 400
页数:12
相关论文
共 20 条
[1]  
[Anonymous], 2011, 14511 UNI EN
[2]   Development and performance mapping of a multi-ejector expansion work recovery pack for R744 vapour compression units [J].
Banasiak, Krzysztof ;
Hafner, Armin ;
Kriezi, Ekaterini E. ;
Madsen, Kenneth B. ;
Birkelund, Michael ;
Fredslund, Kristian ;
Olsson, Rickard .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 57 :265-276
[3]   Experimental and numerical investigation of the influence of the two-phase ejector geometry on the performance of the R744 heat pump [J].
Banasiak, Krzysztof ;
Hafner, Armin ;
Andresen, Trond .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (06) :1617-1625
[4]   Performance analysis of a rooftop, air-to-air heat pump working with CO2 [J].
Calabrese, Nicolandrea ;
Mastrullo, Rita ;
Mauro, Alfonso William ;
Rovella, Paola ;
Tammaro, Marcello .
APPLIED THERMAL ENGINEERING, 2015, 75 :1046-1054
[5]   Experimental validation of a prototype ejector designed to reduce throttling losses encountered in transcritical R744 system operation [J].
Elbel, Stefan ;
Hrnjak, Pega .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (03) :411-422
[6]   Review of recent developments in advanced ejector technology [J].
Elbel, Stefan ;
Lawrence, Neal .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 62 :1-18
[7]   Historical and present developments of ejector refrigeration systems with emphasis on transcritical carbon dioxide air-conditioning applications [J].
Elbel, Stefan .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (07) :1545-1561
[8]  
Goetzler W, 2014, Research & Development Roadmap for Next-Generation Low Global Warming Potential Refrigerants
[9]   Multi-ejector R744 booster refrigerating plant and air conditioning system integration-A theoretical evaluation of energy benefits for supermarket applications [J].
Gullo, Paride ;
Hafner, Armin ;
Cortella, Giovanni .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 75 :164-176
[10]   Experimental analysis of the R744 vapour compression rack equipped with the multiejector expansion work recovery module [J].
Haida, Michal ;
Banasiak, Krzysztof ;
Smolka, Jacek ;
Hafner, Armin ;
Eikevik, Trygve M. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 64 :93-107