L-lactate measures in brain tissue with ceramic-based multisite microelectrodes

被引:70
作者
Burmeister, JJ
Palmer, M
Gerhardt, GA
机构
[1] Univ Kentucky, Chandler Med Ctr, Dept Anat & Neurobiol,Ctr Sensor Technol, Morris K Udall Parkinsons Dis Res Ctr Excellence, Lexington, KY 40536 USA
[2] Univ Kentucky, Chandler Med Ctr, Dept Neurol,Ctr Sensor Technol, Morris K Udall Parkinsons Dis Res Ctr Excellence, Lexington, KY 40536 USA
[3] Univ Colorado, Hlth Sci Ctr, Dept Pharmacol, Denver, CO 80202 USA
关键词
lactate; neurotransmitters; voltammetry; biosensor; CNS;
D O I
10.1016/j.bios.2004.07.003
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A newly developed multisite array microelectrode for in vivo measurements Of L-lactate is presented. The resulting microelectrode is composed of three functional layers. First, Nation is used to repel interfering electroactive anions, such as ascorbate. Second, L-lactate oxidase immobilized onto the recording sites is used to convert L-lactate to hydrogen peroxide. The H2O2 produced is proportional to L-lactate concentrations and is quantified at the platinum recording sites. Third, a layer of polyurethane is coated over the L-lactate oxidase to adjust the linear range of the microelectrode to one that is compatible with in vivo measurements. This layer reduces the amount Of L-lactate that diffuses to the enzyme while not significantly limiting oxygen diffusion. The resulting L-lactate microelectrodes were linear to 20 mM (R-2 = 0.997 +/- 0.001) and beyond in some cases with detection limits of 0.078 +/- 0.013 mM (n = 12). The selectivity and response time of these electrodes make them suitable for in vivo measurements in brain tissue. Self-referencing recordings may be utilized to further improve the selectivity of the recordings. However this is not necessary for most applications in the brain, because the resting and stimulated levels of dopamine (DA), norepinephrine (NE), and other potentially interfering cations are two to three orders of magnitude lower than that of in Vivo L-lactate, which is in the millimolar range. Preliminary in vivo measures Of L-lactate in the brain of anesthetized rats support that the microelectrodes are capable of measuring rapid endogenous changes in vivo. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:1772 / 1779
页数:8
相关论文
共 44 条
[1]   DESIGN AND INVITRO STUDIES OF A NEEDLE-TYPE GLUCOSE SENSOR FOR SUBCUTANEOUS MONITORING [J].
BINDRA, DS ;
ZHANG, YN ;
WILSON, GS ;
STERNBERG, R ;
THEVENOT, DR ;
MOATTI, D ;
REACH, G .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1692-1696
[2]   A flow-through amperometric sensor based on dialysis tubing and free enzyme reactors [J].
Böhm, S ;
Pijanowska, D ;
Olthuis, W ;
Bergveld, P .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (06) :391-397
[3]   Improved ceramic-based multisite microelectrode for rapid measurements of L-glutamate in the CNS [J].
Burmeister, JJ ;
Pomerleau, F ;
Palmer, M ;
Day, BK ;
Huettl, P ;
Gerhardt, GA .
JOURNAL OF NEUROSCIENCE METHODS, 2002, 119 (02) :163-171
[4]   Self referencing ceramic based multisite microelectrodes for the detection and elimination of interferences from the measurement of L-glutamate and other analytes [J].
Burmeister, JJ ;
Gerhardt, GA .
ANALYTICAL CHEMISTRY, 2001, 73 (05) :1037-1042
[5]   Ceramic-based multisite microelectrode array for rapid choline measures in brain tissue [J].
Burmeister, JJ ;
Palmer, M ;
Gerhardt, GA .
ANALYTICA CHIMICA ACTA, 2003, 481 (01) :65-74
[6]   Ceramic-based multisite microelectrodes for electrochemical recordings [J].
Burmeister, JJ ;
Moxon, K ;
Gerhardt, GA .
ANALYTICAL CHEMISTRY, 2000, 72 (01) :187-192
[7]   Ultra-low-volume, real-time measurements of lactate from the single heart cell using microsystems technology [J].
Cai, XX ;
Klauke, N ;
Glidle, A ;
Cobbold, P ;
Smith, GL ;
Cooper, JM .
ANALYTICAL CHEMISTRY, 2002, 74 (04) :908-914
[8]   CLEARANCE OF EXOGENOUS DOPAMINE IN RAT DORSAL STRIATUM AND NUCLEUS-ACCUMBENS - ROLE OF METABOLISM AND EFFECTS OF LOCALLY APPLIED UPTAKE INHIBITORS [J].
CASS, WA ;
ZAHNISER, NR ;
FLACH, KA ;
GERHARDT, GA .
JOURNAL OF NEUROCHEMISTRY, 1993, 61 (06) :2269-2278
[9]   In vitro optimisation of a microdialysis system with potential for on-line monitoring of lactate and glucose in biological samples [J].
Dempsey, E ;
Diamond, D ;
Smyth, MR ;
Malone, MA ;
Rabenstein, K ;
McShane, A ;
McKenna, M ;
Keaveny, TV ;
Freaney, R .
ANALYST, 1997, 122 (02) :185-189
[10]   Evaluation of a lactate sensor for rapid repeated measurements of blood lactate concentration [J].
Divatia, JV ;
Jacques, T ;
Day, P ;
Bihari, DJ .
ANAESTHESIA AND INTENSIVE CARE, 1998, 26 (02) :184-188