Vacuum-assisted headspace solid phase microextraction: Improved extraction of semivolatiles by non-equilibrium headspace sampling under reduced pressure conditions

被引:71
作者
Psillakis, Elefteria [1 ]
Yiantzi, Evangelia [1 ]
Sanchez-Prado, Lucia [1 ]
Kalogerakis, Nicolas [1 ]
机构
[1] Tech Univ Crete, Dept Environm Engn, GR-73100 Polytechneioupolis, Chania, Greece
关键词
Sample preparation; HSSPME; Evaporation rates; Reduced pressure sampling; Non-equilibrium sampling; MASS-TRANSFER COEFFICIENT; LOW-SOLUBILITY CONTAMINANTS; QUANTITATIVE-ANALYSIS; ORGANIC-COMPOUNDS; AQUEOUS-SOLUTIONS; WATER BODIES; VOLATILIZATION; DIFFUSIVITY; EVAPORATION; INTERFACE;
D O I
10.1016/j.aca.2012.01.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new headspace solid-phase microextraction (HSSPME) procedure carried out under vacuum conditions is proposed here where sample volumes commonly used in HSSPME (9 mL) were introduced into pre-evacuated commercially available large sampling chambers (1000 mL) prior to HSSPME sampling. The proposed procedure ensured reproducible conditions for HSSPME and excluded the possibility of analyte losses. A theoretical model was formulated demonstrating for the first time the pressure dependence of HSSPME sampling procedure under non equilibrium conditions. Although reduced pressure conditions during HSSPME sampling are not expected to increase the amount of analytes extracted at equilibrium, they greatly increase extraction rates compared to HSSPME under atmospheric pressure due to the enhancement of evaporation rates in the presence of an air-evacuated headspace. The effect is larger for semivolatiles whose evaporation rates are controlled by mass transfer resistance in the thin gas film adjacent to the sample/headspace interface. Parameters that affect HSSPME extraction were investigated under both vacuum and atmospheric conditions and the experimental data obtained were used to discuss and verify the theory. The use of an excessively large headspace volume was also considered. The applicability of Vac-HSSPME was assessed using chlorophenols as model compounds yielding linearities better than 0.9915 and detection limits in the low-ppt level. The repeatability was found to vary from 3.1 to 8.6%. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:30 / 36
页数:7
相关论文
共 37 条
[1]   Solid phase microextraction in headspace analysis. Dynamics in non-steady state mass transfer [J].
Ai, J .
ANALYTICAL CHEMISTRY, 1998, 70 (22) :4822-4826
[2]   Solid phase microextraction for quantitative analysis in nonequilibrium situations [J].
Ai, J .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :1230-1236
[3]   Headspace solid phase microextraction. Dynamics and quantitative analysis before reaching a partition equilibrium [J].
Ai, J .
ANALYTICAL CHEMISTRY, 1997, 69 (16) :3260-3266
[4]   SOLUBILITY OF PENTACHLOROPHENOL IN AQUEOUS-SOLUTIONS - THE PH EFFECT [J].
ARCAND, Y ;
HAWARI, J ;
GUIOT, SR .
WATER RESEARCH, 1995, 29 (01) :131-136
[5]   Determination of phenols by solid-phase microextraction [J].
Bartak, P ;
Cap, L .
JOURNAL OF CHROMATOGRAPHY A, 1997, 767 (1-2) :171-175
[6]   Thin-film microextraction [J].
Bruheim, I ;
Liu, XC ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 2003, 75 (04) :1002-1010
[7]   The effects of temperature and pressure on the performance of Carboxen/PDMS fibres during solid phase microextraction (SPME) of headspace volatiles from cooked and raw turkey breast [J].
Brunton, NP ;
Cronin, DA ;
Monahan, FJ .
FLAVOUR AND FRAGRANCE JOURNAL, 2001, 16 (04) :294-302
[8]   Volatilization characteristics of organic compounds in the coagulation process [J].
Chao, HP ;
Lee, JF ;
Lee, CK ;
Huang, HC .
JOURNAL OF ENVIRONMENTAL ENGINEERING, 2005, 131 (09) :1253-1259
[9]  
Chiou C.T., 1980, Environment International, V3, P231, DOI [DOI 10.1016/0160-4120(80)90123-3, 10.1016/0160-4120(80)90123-3]
[10]   New approach of solid-phase microextraction improving the extraction yield of butyl and phenyltin compounds by combining the effects of pressure and type of agitation [J].
Darrouzès, J ;
Bueno, M ;
Pécheyran, C ;
Holeman, M ;
Potin-Gautier, M .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1072 (01) :19-27