Passive emission colorimetric sensor (PECS) for measuring emission rates of formaldehyde based on an enzymatic reaction and reflectance photometry

被引:17
作者
Shinohara, Naohide [1 ]
Kajiwara, Tomohisa [2 ]
Ohnishi, Masato [2 ]
Kodama, Kenichi [2 ]
Yanagisawa, Yukio [3 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Res Inst Sci Safety & Sustainabil RISS, Tsukuba, Ibaraki 3058569, Japan
[2] Nippon Living Co Ltd, Ohta Ku, Tokyo 1430024, Japan
[3] Univ Tokyo, Grad Sch Frontier Sci, Dept Environm Syst, Tokyo 1138656, Japan
关键词
D O I
10.1021/es7029762
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A coin-sized passive emission colorimetric sensor (PECS) based on an enzymatic reaction and a portable reflectance photometry device were developed to determine the emission rates of formaldehyde from building materials and other materials found indoors in only 30 minutes on-site. The color change of the PECS linearly correlated to the concentration of formaldehyde aqueous solutions up to 28 mu g/mL. The correlation between the emission rates measured by using the PECS and those measured by using a desiccator method or by using a chamber method was fitted with a linear function and a power function, and the determination coefficients were more than 0.98. The reproducible results indicate that the emission rates could be obtained with the correlation equations from the data measured by using the PECS and the portable reflectance photometry device. Limits of detection (LODS) were 0.051 mg/L for the desiccator method and 3.1 mu g/m(2)/h for the chamber method. Thus, it was confirmed that the emission rates of formaldehyde from the building materials classified as F four-star (< 0.3 mg/L(desiccator method) or < 5.0 mu g/m(2)/h (chamber method)), based on Japanese Industrial Standards (JIS), could be measured with the PECS. The measurement with PECS was confirmed to be precise (RSD < 10%). Other chemicals emitted from indoor materials, such as methanol, ethanol, acetone, toluene, and xylene, interfered little with the measurement of formaldehyde emission rates by using the PECS.
引用
收藏
页码:4472 / 4477
页数:6
相关论文
共 26 条
  • [1] AKUTSU T, 2000, ANN M ARCH I JAP D 2, V2, P721
  • [2] *AM SOC TEST MAT, 1997, D511697 AM SOC TEST
  • [3] *AM SOC TEST MAT, 1996, E133396 AM SOC TEST
  • [4] [Anonymous], 2001, A1460 JIS
  • [5] [Anonymous], 2000, WHO AIR QUAL GUID EU
  • [6] AOKI R, 2000, ANN M ARCH I JAP D 2, V2, P719
  • [7] ASPECTS OF TETRAZOLIUM SALT REDUCTION RELEVANT TO QUANTITATIVE HISTOCHEMISTRY
    EADIE, MJ
    KUKUMS, JR
    HOOPER, WD
    [J]. HISTOCHEMIE, 1970, 21 (02): : 170 - &
  • [8] *EHC, 1997, ENV HLTH CRIT, V190
  • [9] A study on emission of phthalate esters from plastic materials using a passive flux sampler
    Fujii, M
    Shinohara, N
    Lim, A
    Otake, T
    Kumagai, K
    Yanagisawa, Y
    [J]. ATMOSPHERIC ENVIRONMENT, 2003, 37 (39-40) : 5495 - 5504
  • [10] *I HLTH CONS PROT, 1999, ENV7171 I HLTH CON P