Breast Implant Imaging Surveillance among US Plastic Surgeons: US Food and Drug Administration Recommendations versus Clinical Reality

被引:24
作者
Carr, Logan W.
Roberts, John
Mericli, Alex F.
Liu, Jun
Arribas, Elsa M.
Clemens, Mark W.
机构
[1] Penn State Univ, Dept Surg, Div Plast Surg, Coll Med, Hershey, PA USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Plast Surg, Houston, TX 77030 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Diagnost Radiol, Houston, TX 77030 USA
关键词
CAPSULAR CONTRACTURE; RUPTURE; ULTRASOUND; MAMMOGRAPHY; DIAGNOSIS;
D O I
10.1097/PRS.0000000000006812
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Device rupture is considered a major complication associated with breast implants. The U.S. Food and Drug Administration recommends magnetic resonance imaging (MRI) surveillance 3 years after implantation and then every 2 years, but adherence to these recommendations is poor. The authors identified current practice management for breast implant rupture surveillance by surveying practicing U.S. plastic surgeons. Methods: An online survey of all active members of the American Society of Plastic Surgeons was performed. Questions analyzed imaging practice patterns related to breast implants. Logistic regression models were used to analyze determinants for radiographic imaging in breast implant patients. Results: The survey had a response rate of 16.5 percent. For patients with breast implants, 37.7 percent of respondents recommended MRI at the recommended intervals. Fifty-five percent perform imaging only if there is a problem with the implant. Academic surgeons more frequently recommended MRI (56.3 percent and 39.3 percent; p = 0.0002). Surgeons with less than 5 years of experience are four times more likely to order MRI than surgeons with over 25 years' experience (60.8 percent and 28.1 percent; p < 0.0001). Furthermore, lower volume surgeons recommend significantly more MRI (45.2 percent and 27.3 percent; p = 0.001). Respondents are almost two times more likely to recommend MRI in reconstructive versus cosmetic patients (51.2 percent and 35.6 percent; p = 0.0004). Conclusions: MRI limitations include high costs, time commitments, and equipment constraints. Fewer than 40 percent of survey respondents suggest the recommended screening frequency to their patients; however, academic, low-volume, early-career surgeons are more likely to recommend MRI implant monitoring. Screening recommendations need to be evidence based and align with common practices to prevent undue system, provider, and patient burden.
引用
收藏
页码:1381 / 1387
页数:7
相关论文
共 31 条
[1]   Macrotextured Breast Implants with Defined Steps to Minimize Bacterial Contamination around the Device: Experience in 42,000 Implants [J].
Adams, William P., Jr. ;
Culbertson, Eric J. ;
Deva, Anand K. ;
Magnusson, Mark R. ;
Layt, Craig ;
Jewell, Mark L. ;
Mallucci, Patrick ;
Heden, Per .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2017, 140 (03) :427-431
[2]  
American Health Imaging, MUCH DOES MRI COST
[3]  
Ashford, 2014, FORBES
[4]   High-Resolution Ultrasound in the Detection of Silicone Gel Breast Implant Shell Failure: Background, In Vitro Studies, and Early Clinical Results [J].
Bengtson, Bradley P. ;
Eaves, Felmont F. .
AESTHETIC SURGERY JOURNAL, 2012, 32 (02) :157-174
[5]   Economic Analysis of Screening Strategies for Rupture of Silicone Gel Breast Implants [J].
Chung, Kevin C. ;
Malay, Sunitha ;
Shauver, Melissa J. ;
Kim, H. Myra .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2012, 130 (01) :225-237
[6]   Magnetic resonance imaging and explantation investigation of long-term silicone gel implant integrity [J].
Collis, Nick ;
Litherland, Janet ;
Enion, David ;
Sharpe, David T. .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2007, 120 (05) :1401-1406
[7]   US FDA Breast Implant Postapproval Studies Long-term Outcomes in 99,993 Patients [J].
Coroneos, Christopher J. ;
Selber, Jesse C. ;
Offodile, Anaeze C. ;
Butler, Charles E. ;
Clemens, Mark W. .
ANNALS OF SURGERY, 2019, 269 (01) :30-36
[8]   The mentor study on contour profile gel silicone MemoryGel breast implants [J].
Cunningham, Bruce .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2007, 120 (07) :33S-39S
[9]   Comparative Study of Breast Implant Rupture Using Mammography, Sonography, and Magnetic Resonance Imaging: Correlation with Surgical Findings [J].
Di Benedetto, Giovanni ;
Cecchini, Sara ;
Grassetti, Luca ;
Baldassarre, Silvia ;
Valeri, Gianluca ;
Leva, Luca ;
Giuseppetti, Gian Marco ;
Bertani, Aldo .
BREAST JOURNAL, 2008, 14 (06) :532-537
[10]   DIAGNOSIS OF BREAST IMPLANT RUPTURE - IMAGING FINDINGS AND RELATIVE EFFICACIES OF IMAGING TECHNIQUES [J].
EVERSON, LI ;
PARANTAINEN, H ;
DETLIE, T ;
STILLMAN, AE ;
OLSON, PN ;
LANDIS, G ;
FOSHAGER, MC ;
CUNNINGHAM, B ;
GRIFFITHS, HJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (01) :57-60