Partial least-squares analysis of time decay data for Eu(III)-tetracycline complexes Simultaneous luminescent determination of tetracycline and oxytetracycline in bovine serum

被引:26
作者
Ibanez, Gabriela A. [1 ,2 ]
机构
[1] Univ Nacl Rosario, Dept Quim Analit, Fac Ciencias Bioquim & Farmaceut, RA-2000 Rosario, Argentina
[2] Consejo Nacl Invest Cient & Tecn, Inst Quim Rosario IQUIR, Rosario, Argentina
关键词
tetracyclines; lanthanide-sensitized luminescence; europium; partial least-squares; bovine serum;
D O I
10.1016/j.talanta.2007.12.044
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and sensitive methodology to simultaneously quantify tetracycline and oxytetracycline in bovine serum samples is described. The method combines the advantages of the lanthanide-sensitized luminescence (i.e., sensitivity and selectivity) with partial least-squares (PLS) analysis, and requires no previous separation steps. Due to the strong overlapping of emission and excitation spectra of the analytes and their europium complexes, the luminescence decay curve (intensity of luminescence vs. time) of analyte-Eu complex was selected to resolve mixtures of tetracycline and oxytetracycline. Partial least-squares uses the luminescence decay as discriminatory parameter and regresses the luminescence versus time onto the concentrations of standards. Using a 16-sample aqueous calibration set, 10 validation samples, I I spiked serum bovine samples and a blank of serum were studied. The analyte recoveries from serum samples ranged from 87 to 104% for tetracycline and from 94 to 106% for oxytetracycline. The results obtained by the developed method were statistically comparable to those obtained with high performance liquid chromatography. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1028 / 1034
页数:7
相关论文
共 57 条
[1]   Simultaneous kinetic spectrophotometric determination of cyanide and thiocyanate using the partial least squares (PLS) regression [J].
Afkhami, Abbas ;
Sarlak, Nahid ;
Zarei, Ali Reza .
TALANTA, 2007, 71 (02) :893-899
[2]   Application of ELISA in determining the fate of tetracyclines in land-applied livestock wastes [J].
Aga, DS ;
Goldfish, R ;
Kulshrestha, P .
ANALYST, 2003, 128 (06) :658-662
[3]   KALMAN FILTERING-AIDED TIME-RESOLVED SOLID-SURFACE ROOM-TEMPERATURE PHOSPHORIMETRY FOR SIMULTANEOUS DETERMINATION OF TETRACYCLINES IN SOLUTION [J].
ALAVAMORENO, F ;
LIU, YM ;
DIAZGARCIA, ME ;
SANZMEDEL, A .
MIKROCHIMICA ACTA, 1993, 112 (1-4) :47-54
[4]   Determination of tetracycline residues in shrimp and whole milk using liquid chromatography with ultraviolet detection and residue confirmation by mass spectrometry [J].
Andersen, WC ;
Roybal, JE ;
Gonzales, SA ;
Turnipseed, SB ;
Pfenning, AP ;
Kuck, LR .
ANALYTICA CHIMICA ACTA, 2005, 529 (1-2) :145-150
[5]   Complexities in tetracycline analysis - chemistry, matrix extraction, cleanup, and liquid chromatography [J].
Anderson, CR ;
Rupp, HS ;
Wu, WH .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1075 (1-2) :23-32
[6]  
[Anonymous], 1989, MULTIVARIATE CALIBRA
[7]  
*AOAC INT, 2000, AOAC OFF METH AN, V23
[8]   Sensitive detection of tetracyclines using europium-sensitized fluorescence with EDTA as co-ligand and cetyltrimethylammonium chloride as surfactant [J].
Arnaud, N ;
Georges, J .
ANALYST, 2001, 126 (05) :694-697
[9]   SPECTROFLUOROMETRIC DETERMINATION OF TETRACYCLINE AND ANHYDROTETRACYCLINE IN SERUM AND URINE [J].
CHANG, WB ;
ZHAO, YB ;
CI, YX ;
HU, LY .
ANALYST, 1992, 117 (08) :1377-1378
[10]   Thin-layer chromatography - matrix-assisted laser desorption ionisation - time-of-flight mass spectrometry using particle suspension matrices [J].
Crecelius, A ;
Clench, MR ;
Richards, DS ;
Parr, V .
JOURNAL OF CHROMATOGRAPHY A, 2002, 958 (1-2) :249-260