The best knot and suture configurations for high-strength suture material. An in vitro biomechanical study

被引:31
作者
Meyer, Dominik C. [1 ]
Bachmann, Elias [1 ]
Laedermann, Alexandre [2 ,3 ,4 ]
Lajtai, Georg [5 ]
Jentzsch, Thorsten [1 ]
机构
[1] Univ Zurich, Balgrist Univ Hosp, Dept Orthoped, Forchstr 340, CH-8008 Zurich, Switzerland
[2] La Tour Hosp, Div Orthopaed & Trauma Surg, Meyrin, Switzerland
[3] Univ Geneva, Fac Med, Geneva, Switzerland
[4] Geneva Univ Hosp, Dept Surg, Div Orthopaed & Trauma Surg, Geneva, Switzerland
[5] Private Hosp Maria Hilf, Orthoped Dept, Klagenfurt, Karnten, Austria
关键词
Knot; Cow hitch (Lark's head); Half hitch; Knot security (stiffness); Loop security (tension); Size; ARTHROSCOPIC KNOTS; HALF-HITCHES; SLIDING KNOT; TENDON; BEHAVIOR;
D O I
10.1016/j.otsr.2018.08.010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: Surgical knots are particularly challenged by high-strength suture material. It was hypothesized that sutures in a double-stranded looped configuration present mechanical advantages. Methods: This in vitro biomechanical study repeatedly tested 12 different knots with a static distraction material testing machine with a constant tensile speed. The cow hitch, its altered version, and conventional half hitches were also tested on bovine tendon. Suture material was braided polyblend non-bioresorbable polyester. Primary outcome was knot security (stiffness) at clinical failure (>= 3 mm displacement). Secondary outcomes were knot size and loop security. Results: Double-stranded looped knots were up to three times stronger than one and a half- and single-stranded knots. The cow hitch was stiffest (mean 185 [95% CI 172-197] Newton per millimeter [N/mm])(p < 0.001), followed by the Nice knot (169 [154-183] N/mm). It was stiffer than half hitches (65 [53-78] N/mm). These findings remained in tendons (82 [77-86] and 40 [32-49] N/mm, p< 0.001). The cow hitch (7.6 mm(3)) and Nice knot (6.1 mm 3 ) were smaller than half hitches (9.5 mm(3)). Loop security did not differ between the cow hitch and Nice knot, but was higher in the cow hitch than half hitch (158 [120-196]N and 85 [57-113]N, p< 0.001). Conclusions: Double-stranded knot configurations with a loop on one side are mechanically stronger and stiffer, less bulky, and preserve applied tension during tying better than conventional knots. The best performing and technically most simple knots best suited to exploit enormous mechanical capabilities of modern high-strength suture material are the cow hitch and Nice knot. (C) 2018 Published by Elsevier Masson SAS.
引用
收藏
页码:1277 / 1282
页数:6
相关论文
共 27 条
[1]   A Clove-Hitch Suture Method for Small-Caliber Tendon Ends [J].
Abraham, Edward ;
League, Alan ;
Amirouche, Farid ;
Kulkarni, Nikhil .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (14) :1303-1307
[2]   Cyclic Load and Failure Behavior of Arthroscopic Knots and High Strength Sutures [J].
Barber, F. Alan ;
Herbert, Morley A. ;
Beavis, R. Cole .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2009, 25 (02) :192-199
[3]   An in vitro analysis of the mechanical properties of 16 arthroscopic knots [J].
Baumgarten, Keith M. ;
Brodt, Michael D. ;
Silva, Matthew J. ;
Wright, Rick W. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2008, 16 (10) :957-966
[4]  
Baumgarten Keith M, 2010, Am J Orthop (Belle Mead NJ), V39, P577
[5]   Influence of suture material on the biomechanical behavior of suture-tendon specimens - A controlled study in bovine rotator cuff [J].
Bisson, Leslie J. ;
Manohar, Leslie M. ;
Wilkins, Ryan D. ;
Gurske-Deperio, Jennifer ;
Ehrensberger, Mark T. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2008, 36 (05) :907-912
[6]  
Boileau P, 2010, DOUBLED SUTURE NICE
[7]   Can Genipin-coated Sutures Deliver a Collagen Crosslinking Agent to Improve Suture Pullout in Degenerated Tendon? An Ex Vivo Animal Study [J].
Camenzind, Roland S. ;
Tondelli, Timo O. ;
Gotschi, Tobias ;
Holenstein, Claude ;
Snedeker, Jess G. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2018, 476 (05) :1104-1113
[8]  
Chokshi BV, 2007, BULL HOSP JT DIS, V65, P306
[9]   Biomechanical Performance of Traditional Arthroscopic Knots Versus Slippage-Proof Knots [J].
Clark, Randy R. ;
Dierckman, Brian ;
Sampaticos, Nels ;
Snyder, Stephen .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2013, 29 (07) :1175-1181
[10]   The Nice knot as an improvement on current knot options: A mechanical analysis [J].
Collin, P. ;
Laubster, E. ;
Denard, P. J. ;
Akue, F. A. ;
Ladermann, A. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2016, 102 (03) :293-296