Application of Active Middle Ear Implants in Patients With Severe Mixed Hearing Loss

被引:37
作者
Verhaegen, Veronique J. O. [1 ]
Mulder, Jef J. S. [1 ]
Cremers, Cor W. R. J. [1 ]
Snik, Ad F. M. [1 ]
机构
[1] Radboud Uni Nijmegen, Dept Otorhinolaryngol, Med Ctr, Donders Ctr Neurosci, NL-6500 HB Nijmegen, Netherlands
关键词
Draining ears; Implantable hearing aid; Long-term results; Mixed hearing loss; Vibrant Soundbridge; FLOATING MASS TRANSDUCER; ROUND WINDOW STIMULATION; VIBRANT SOUNDBRIDGE; OVAL WINDOW; AID; MEMBRANE; STAPES;
D O I
10.1097/MAO.0b013e3182487f98
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To determine the long-term benefit of the Vibrant Soundbridge (VSB) middle ear implant in patients with severe mixed hearing loss and to compare it with other hearing devices. Design: A retrospective analysis. Setting: University-affiliated medical center. Patients: Six patients with severe mixed hearing loss and a mean sensorineural hearing loss component between 40 and 70 dB. Interventions: Patients received a VSB with the floating mass transducer (FMT) coupled to the round window or to the oval window via a residual stapes structure. Main Outcome Measures: Functional gain and speech recognition results. Results are compared with 2 control groups matched for mean sensorineural hearing loss: 1) patients with mixed hearing loss and a bone-anchored hearing device, and 2) patients with sensorineural hearing loss and traditional implantation of the VSB. Results: There is large variance in functional gain between the patients suggesting high variability in the effectivity of the FMT coupling. The speech recognition results for the experimental group were not systematically better than in either control group. Conclusion: There is large variability in results that might be ascribed to coupling effectivity. On the average, speech recognition results were not better or worse than those found in patients with similar hearing loss fitted with bone-anchored hearing devices.
引用
收藏
页码:297 / 301
页数:5
相关论文
共 25 条
[1]   Factors Improving the Vibration Transfer of the Floating Mass Transducer at the Round Window [J].
Arnold, Andreas ;
Stieger, Christof ;
Candreia, Claudia ;
Pfiffner, Flurin ;
Kompis, Martin .
OTOLOGY & NEUROTOLOGY, 2010, 31 (01) :122-128
[2]  
Baumgartner WD, 2010, ADV OTO-RHINO-LARYNG, V69, P38, DOI 10.1159/000318521
[3]   Coupling the Vibrant Soundbridge to Cochlea Round Window: Auditory Results in Patients With Mixed Hearing Loss [J].
Beltrame, Achille M. ;
Martini, Alessandro ;
Prosser, Silvano ;
Giarbini, Nadia ;
Streitberger, Christian .
OTOLOGY & NEUROTOLOGY, 2009, 30 (02) :194-201
[4]  
Bosman AJ, 1995, AUDIOLOGY, V34, P260
[5]   Fitting range of the BAHA Cordelle [J].
Bosman, Arjan J. ;
Snik, Ad F. M. ;
Mylanus, Emmanuel A. M. ;
Cremers, Cor W. R. J. .
INTERNATIONAL JOURNAL OF AUDIOLOGY, 2006, 45 (08) :429-437
[6]   The Floating Mass Transducer for External Auditory Canal and Middle Ear Malformations [J].
Colletti, Liliana ;
Carner, Marco ;
Mandala, Marco ;
Veronese, Sheila ;
Colletti, Vittorio .
OTOLOGY & NEUROTOLOGY, 2011, 32 (01) :108-115
[7]   Treatment of mixed hearing losses via implantation of a vibratory transducer on the round window [J].
Colletti, Vittorio ;
Soli, Sigfrid D. ;
Carner, Marco ;
Colletti, L. .
INTERNATIONAL JOURNAL OF AUDIOLOGY, 2006, 45 (10) :600-608
[8]  
Collewaert V, 2009, ACTA OTO-LARYNGOL, V8, P1, DOI [10.5465/AMBPP.2009.44256507, DOI 10.5465/AMBPP.2009.44256507]
[9]   The Floating Mass Transducer of the Vibrant Soundbridge Interposed Between the Stapes and Tympanic Membrane After Incus Necrosis [J].
Cremers, Cor W. R. J. ;
Verhaegen, Veronique J. O. ;
Snik, Ad F. M. .
OTOLOGY & NEUROTOLOGY, 2009, 30 (01) :76-78
[10]   Better Performance With Bone-Anchored Hearing Aid Than Acoustic Devices in Patients With Severe Air-Bone Gap [J].
de Wolf, Maarten J. F. ;
Hendrix, Sander ;
Cremers, Cor W. R. J. ;
Snik, Ad F. M. .
LARYNGOSCOPE, 2011, 121 (03) :613-616