Predicting Malignant Lymph Nodes Using a Novel Scoring System Based on Multi-Endobronchial Ultrasound Features

被引:5
作者
Morishita, Momoko [1 ,2 ,3 ]
Uchimura, Keigo [1 ]
Furuse, Hideaki [1 ]
Imabayashi, Tatsuya [1 ]
Tsuchida, Takaaki [1 ]
Matsumoto, Yuji [1 ,2 ]
机构
[1] Natl Canc Ctr, Resp Endoscopy Div, Dept Endoscopy, Chuo Ku, 5-1-1 Tsukiji, Tokyo 1040045, Japan
[2] Natl Canc Ctr, Dept Thorac Oncol, Chuo Ku, 5-1-1 Tsukiji, Tokyo 1040045, Japan
[3] Natl Ctr Global Hlth & Med, Dept Resp Med, Shinjuku Ku, 1-21-1 Toyama, Tokyo 1628655, Japan
关键词
bronchoscopy; cytology; endobronchial ultrasound; transbronchial needle aspiration; histology; lung cancer; elastography; TRANSBRONCHIAL NEEDLE ASPIRATION; LUNG-CANCER; SONOGRAPHIC FEATURES; STRAIN ELASTOGRAPHY; NODAL METASTASIS; DIAGNOSIS;
D O I
10.3390/cancers14215355
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Simple Summary Endobronchial ultrasound (EBUS) features help differentiate between benign and malignant lymph nodes (MLNs) during transbronchial needle aspiration (TBNA). B-, power/color Doppler, and elastography modes are used during EBUS-TBNA. However, only few studies have assessed them simultaneously. This study evaluated multi-EBUS features (B-, power/color Doppler, and elastography modes) and established a novel scoring system. Multivariable analysis revealed that short axis (>1 cm), heterogeneous echogenicity, absence of central hilar structure, presence of coagulation necrosis sign, and blue-dominant elastographic images were independent predictors of MLNs. At three or more EBUS features predicting MLNs, our scoring system had high sensitivity and specificity (77.9 and 91.8%, respectively). The area under the receiver operating curve (AUC) was 0.894 (95% confidence interval (CI): 0.868-0.920), higher than that of B-mode features alone (AUC: 0.840 (95% CI: 0.807-0.873)). Our novel scoring system could predict MLNs more accurately than B-mode features alone. Endobronchial ultrasound (EBUS) features with B-, power/color Doppler, and elastography modes help differentiate between benign and malignant lymph nodes (MLNs) during transbronchial needle aspiration (TBNA); however, only few studies have assessed them simultaneously. We evaluated the diagnostic accuracy of each EBUS feature and aimed to establish a scoring system to predict MLNs. EBUS features of consecutive patients and final diagnosis per lymph node (LN) were examined retrospectively. In total, 594 LNs from 301 patients were analyzed. Univariable analyses revealed that EBUS features, except for round shape, could differentiate MLNs from benign LNs. Multivariable analysis revealed that short axis (>1 cm), heterogeneous echogenicity, absence of central hilar structure, presence of coagulation necrosis sign, and blue-dominant elastographic images were independent predictors of MLNs. At three or more EBUS features predicting MLNs, our scoring system had high sensitivity (77.9%) and specificity (91.8%). The area under the receiver operating curve (AUC) was 0.894 (95% confidence interval (CI): 0.868-0.920), which was higher than that of B-mode features alone (AUC: 0.840 (95% CI: 0.807-0.873)). The novel scoring system could predict MLNs more accurately than B-mode features alone. Multi-EBUS features may increase EBUS-TBNA efficiency for LN evaluation.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Elucidating the Etiologies of 18F-fluorodeoxyglucose-Avid Mediastinal Lymph Nodes Among Cancer Patients in a Tuberculosis- Endemic Region Using Endobronchial Ultrasound
    Khalid, Usman
    Akram, Muhammad J.
    Abu Bakar, Muhammad
    Butt, Faheem M.
    Ashraf, Mohammad B.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (11)
  • [32] Diagnostic value of endobronchial ultrasound elastography for the differentiation of benign and malignant intrathoracic lymph nodes
    Boonsarngsuk, Viboon
    Korrungruang, Potjanee
    EUROPEAN RESPIRATORY JOURNAL, 2016, 48
  • [33] A novel online education module to teach clinicians how to correctly identify ultrasonographic features of mediastinal lymph nodes during endobronchial ultrasound
    Hylton, Danielle A.
    Shargall, Yaron
    Finley, Christian
    Agzarian, John
    Fahim, Christine
    Hanna, Wael C.
    CANADIAN JOURNAL OF SURGERY, 2020, 63 (01) : E62 - E68
  • [34] Endobronchial ultrasound elastography for the prediction of malignant intrathoracic lymph nodes during EBUS-TBNA
    Sun, Jiayuan
    Wang, Lei
    Mao, Xiaowei
    Zheng, Xiaoxuan
    Han, Baohui
    EUROPEAN RESPIRATORY JOURNAL, 2016, 48
  • [35] Quantitative evaluation of endobronchial ultrasound elastography in the diagnosis of benign and malignant mediastinal and hilar lymph nodes
    Wang, Zhen
    Bai, Jiayu
    Jiao, Guangyu
    Li, Peng
    RESPIRATORY MEDICINE, 2024, 224
  • [36] The Role of Convex Probe Endobronchial Ultrasound Guided Transbronchial Needle Aspiration in the Diagnosis of Malignant Mediastinal and Hilar Lymph Nodes
    Caglayan, Benan
    Salepci, Banu
    Dogusoy, Ilgaz
    Fidan, Ali
    Comert, Sevda Sener
    Kiral, Nesrin
    Yavuzer, Dilek
    Sarac, Gulsen
    IRANIAN JOURNAL OF RADIOLOGY, 2012, 9 (04) : 183 - 189
  • [37] Diagnosis and Subclassification of Lymphomas and Non-Neoplastic Lesions Involving Mediastinal Lymph Nodes Using Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration
    Ko, Hyang Mi
    Santos, Gilda da Cunha
    Darling, Gail
    Pierre, Andrew
    Yasufuku, Kazuhiro
    Boerner, Scott L.
    Geddie, William R.
    DIAGNOSTIC CYTOPATHOLOGY, 2013, 41 (12) : 1023 - 1030
  • [38] Diagnosis of Mesothelioma Using Flexible Bronchoscopy With Endobronchial Ultrasound-guided Biopsy of Mediastinal Lymph Nodes
    Mukherjee, Indrani
    Yi, Eunhee
    Utz, James
    JOURNAL OF BRONCHOLOGY & INTERVENTIONAL PULMONOLOGY, 2009, 16 (03) : 207 - 210
  • [39] A comparision of endobronchial ultrasound-guided transbronchial needle aspiration and integrated positron emission tomography-computed tomography in the diagnosis of malignant mediastinal/hilar lymph nodes
    Comert, Sevda Sener
    Caglayan, Benan
    Fidan, Ali
    Salepci, Banu
    Dogan, Coskun
    Demirhan, Recep
    Ece, Dilek
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 20 (04): : 843 - 849
  • [40] Per-Esophageal Needle Aspiration of Parenchymal Lung Lesions and Mediastinal Lymph Nodes Using an Endobronchial Ultrasound Bronchoscope
    Hakrush, Omar
    Adir, Yochai
    Schneer, Sonia
    Abramovic, Amir
    ISRAEL MEDICAL ASSOCIATION JOURNAL, 2019, 21 (11): : 738 - 742