Effect of Electrode Configuration on the Wastewater Treatment by Underwater Electrical Streamer Discharge

被引:2
|
作者
Wen, Xiao Qiong [1 ]
Wang, Ming [1 ]
Liu, Xue Hua [2 ]
机构
[1] Dalian Univ Technol, Sch Phys & Optoelect Technol, Ctr Plasma Sci & Engn, Dalian 116024, Peoples R China
[2] Beijing Jiaotong Univ, Haibin Coll, Phys Grp, Huanghua 061100, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrode configuration; underwater electrical streamer discharge; wastewater treatment; PULSED-CORONA DISCHARGES; NONTHERMAL PLASMA; DISINFECTION; LIQUIDS; REACTOR; WIRE;
D O I
10.1109/TPS.2011.2169433
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
The effect of electrode configuration on wastewater treatment by underwater electrical streamer discharge is investigated by comparing a coaxial rod-to-cylinder electrode configuration with a point-to-cylinder one. By using a brilliant-blue FCF solution as monitor pollutants, the dissipated energy per pulse, the degradation rate constant, and the energy consumption in both electrode configurations are compared under different solution conductivities or pH values. The coaxial rod-to-cylinder electrode configuration can dissipate as about three times of energy into the solution as the point-to-cylinder one does during one discharge pulse in our experiment. In both electrode configurations, the degradation of the brilliant-blue FCF solution follows a pseudo first-order rate profile. The degradation rate constant is not significantly influenced by the solution conductivity, but it decreases with increasing the solution pH value. Comparing with the point-to-cylinder configuration, the degradation rate constant in the rod-to-cylinder one was improved by a factor of about 4.3, 3.6, and 2.9 at solution pH = 4, 7.8, and 10, respectively. The energy consumption increases with increasing the solution conductivity or the solution pH value in both electrode configurations, but it is significantly lower in the rod-to-cylinder one when the solution pH < 8. Fixing the solution conductivity at 150 mu S/cm, the energy consumption in the rod-to-cylinder system decreases by about 30% and 20% at solution pH = 4 and 7.8, respectively.
引用
收藏
页码:1089 / 1093
页数:5
相关论文
共 50 条
  • [31] A New Electrode Configuration Scheme in Electrical Impedance Tomography for Thorax Imaging
    Dai, Muchen
    Zhang, Ke
    Li, Maokun
    Yang, Fan
    Xu, Shenheng
    Wang, Yibing
    2018 INTERNATIONAL APPLIED COMPUTATIONAL ELECTROMAGNETICS SOCIETY SYMPOSIUM IN CHINA (ACES-CHINA 2018), 2018,
  • [32] Effect of the Length of the Interelectrode Gap during an Underwater Spark Discharge and the Length of a Conductor during Its Underwater Electrical Explosion on the Amplitude of the Generated Pressure Wave
    Smirnov, A. P.
    Zhekul, V. G.
    Khvoshchan, O. V.
    Litvinov, V. V.
    Kovalenko, A. A.
    Konotop, S. V.
    SURFACE ENGINEERING AND APPLIED ELECTROCHEMISTRY, 2020, 56 (05) : 584 - 589
  • [33] EFFECTS OF ELECTRODE CONFIGURATION ON THRESHOLD FUNCTIONS FOR ELECTRICAL-STIMULATION OF THE COCHLEA
    PFINGST, BE
    MORRIS, DJ
    MILLER, AL
    HEARING RESEARCH, 1995, 85 (1-2) : 76 - 84
  • [34] The Configuration Effects of Electrode on the Performance of Dielectric Barrier Discharge Reactor for NOx Removal
    Anaghizi, Saeed Javadi
    Talebizadeh, Pouyan
    Rahimzadeh, Hassan
    Ghomi, Hamidreza
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2015, 43 (06) : 1944 - 1953
  • [35] Desulphurization and Simultaneous Treatment of Wastewater from Blast Furnace by Pulsed Corona Discharge
    Li, Shengli
    Feng, Qiubao
    Li, Lin
    Xie, Chunling
    Zhen, Lianpeng
    ENVIRONMENTAL ENGINEERING SCIENCE, 2009, 26 (03) : 633 - 639
  • [36] Comparison Study on Underwater Bubble Dynamics via Pulsed Discharge and Electrical Explosion
    Bai, Jie
    Han, Ruoyu
    Wang, Manyu
    Feng, Juan
    Sun, Yuanbo
    Li, Pengfei
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2025, 61 (01) : 1202 - 1211
  • [37] Continuous Electrocoagulation for a Sustainable Water Treatment: Effects of Electrode Configuration, Electrical Connection Mode, and Polarity Reversal on Fluoride Removal
    Dhifallah, Sirin
    Attour, Anis
    Vial, Christophe
    Zagrouba, Fethi
    Audonnet, Fabrice
    SUSTAINABILITY, 2024, 16 (13)
  • [38] Predicting fate of the contraceptive pill in wastewater treatment and discharge
    Mastrup, M
    Schäfer, AI
    Khan, SJ
    WATER SCIENCE AND TECHNOLOGY, 2005, 52 (08) : 279 - 286
  • [39] Resourceful treatment of alcohol distillery wastewater by pulsed discharge
    Xin, Yanbin
    Sun, Bing
    Zhu, Xiaomei
    Yan, Zhiyu
    Zhao, Xiaotong
    Sun, Xiaohang
    BIORESOURCE TECHNOLOGY, 2017, 244 : 175 - 181
  • [40] Effect of different electrode configuration modes on the performance of electrocoagulation
    Jaiswar, Vinod Kumar
    Saroha, Anil K.
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2025, 102 (02)