Synchrotron-based phase contrast imaging of cardiovascular tissue in mice-grating interferometry or phase propagation?

被引:2
|
作者
Trachet, Bram [1 ,2 ]
Lovric, Goran [3 ,4 ]
Villanueva-Perez, Pablo [4 ]
Aslanidou, Lydia [1 ]
Ferraro, Mauro [1 ]
Logghe, Gerlinde [2 ]
Stergiopulos, Nikolaos [1 ]
Segers, Patrick [2 ]
机构
[1] Ecole Polytech Fed Lausanne, Inst Bioengn, Lausanne, Switzerland
[2] Univ Ghent, bioMMeda, Ghent, Belgium
[3] Ecole Polytech Fed Lausanne, Ctr Imagerie BioMed, Lausanne, Switzerland
[4] Paul Scherrer Inst, Swiss Light Source, Villigen, Switzerland
来源
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS | 2019年 / 5卷 / 01期
基金
瑞士国家科学基金会;
关键词
synchrotron-based x-ray imaging; grating interferometry; phase propagation; mouse models of cardiovascular disease; AORTIC-ANEURYSM; TOMOGRAPHY; RESOLUTION; DISEASE; MODEL; ARCH;
D O I
10.1088/2057-1976/aaeb65
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Synchrotron-based x-ray phase-contrast imaging allows for detailed 3D insight into the microstructure of soft tissue and is increasingly used to improve our understanding of mouse models of cardiovascular disease. Two techniques dominate the field: grating interferometry, with superior density contrast at mid to lower microscopic resolutions, and propagation-based phase contrast, facilitating high-resolution tissue imaging. The choice between these techniques depends on which features one is interested in visualizing and is thus highly sample-dependent. In this manuscript we systematically evaluate the advantages and disadvantages of grating interferometry and propagation-based phase contrast for the specific application of pre-clinical cardiovascular tissue. We scanned samples obtained from 5 different mouse models of cardiovascular disease, ranging from carotid plaques over ascending and abdominal aortic aneurysms to hypertrophic hearts. Based on our findings we discuss in detail how synchrotron-based imaging can be used to increase our understanding of the anatomy and biomechanics of cardiovascular disease in mice. We also present a flowchart that can help future users to select the best synchrotron-based phase contrast technique for their pre-clinical cardiovascular samples.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Inverse geometry for grating-based x-ray phase-contrast imaging
    Donath, Tilman
    Chabior, Michael
    Pfeiffer, Franz
    Bunk, Oliver
    Reznikova, Elena
    Mohr, Juergen
    Hempel, Eckhard
    Popescu, Stefan
    Hoheisel, Martin
    Schuster, Manfred
    Baumann, Joachim
    David, Christian
    JOURNAL OF APPLIED PHYSICS, 2009, 106 (05)
  • [42] Grating based X-ray phase contrast CT imaging with iterative reconstruction algorithm
    Qi Jun-Cheng
    Chen Rong-Chang
    Liu Bin
    Chen Ping
    Du Guo-Hao
    Xiao Ti-Qiao
    ACTA PHYSICA SINICA, 2017, 66 (05)
  • [43] Tumors in murine brains studied by grating-based phase contrast microtomography
    Schulz, Georg
    Dominietto, Marco
    Kovacs, Zsofia
    Schmitz, Ruediger
    Hieber, Simone E.
    Thalmann, Peter
    Beckmann, Felix
    Mueller, Bert
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IX, 2014, 9212
  • [44] 3D digital anatomic angioarchitecture of the mouse brain using synchrotron-radiation-based propagation phase-contrast imaging
    Shi, Shupeng
    Zhang, Haoran
    Yin, Xianzhen
    Wang, Zhuolu
    Tang, Bin
    Luo, Yuebei
    Ding, Hui
    Chen, Zhuohui
    Cao, Yong
    Wang, Tiantian
    Xiao, Bo
    Zhang, Mengqi
    JOURNAL OF SYNCHROTRON RADIATION, 2019, 26 : 1742 - 1750
  • [45] Heterodyne grating interferometry based on sinusoidal phase modulation for displacement measurement
    Lee, Ju-Yi
    Hsieh, Hung-Lin
    Lin, Zhi Ying
    OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION X, 2017, 10329
  • [46] Synchrotron-based phase-contrast micro-CT as a tool for understanding pulmonary vascular pathobiology and the 3-D microanatomy of alveolar capillary dysplasia
    Norvik, Christian
    Westoo, Christian Karl
    Peruzzi, Niccolo
    Lovric, Goran
    van der Have, Oscar
    Mokso, Rajmund
    Jeremiasen, Ida
    Brunnstrom, Hans
    Galambos, Csaba
    Bech, Martin
    Tran-Lundmark, Karin
    AMERICAN JOURNAL OF PHYSIOLOGY-LUNG CELLULAR AND MOLECULAR PHYSIOLOGY, 2020, 318 (01) : L65 - L75
  • [47] Refracting Rontgen's rays: Propagation-based x-ray phase contrast for biomedical imaging
    Gureyev, T. E.
    Mayo, S. C.
    Myers, D. E.
    Nesterets, Ya.
    Paganin, D. M.
    Pogany, A.
    Stevenson, A. W.
    Wilkins, S. W.
    JOURNAL OF APPLIED PHYSICS, 2009, 105 (10)
  • [48] Synchrotron-based DEI for bio-imaging and DEI-CT to image phantoms with contrast agents
    Rao, Donepudi V.
    Swapna, Medasani
    Cesareo, Roberto
    Brunetti, Antonio
    Akatsuka, Tako
    Yuasa, Tetsuya
    Zhong, Zhong
    Takeda, Tohoru
    Gigante, Giovanni E.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (08) : 1570 - 1578
  • [49] X-ray phase radiography and tomography of soft tissue using grating interferometry
    Weitkamp, Timm
    David, Christian
    Bunk, Oliver
    Bruder, Jens
    Cloetens, Peter
    Pfeiffer, Franz
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (03) : S13 - S17
  • [50] Comparison of image properties in full-field phase X-ray microscopes based on grating interferometry and Zernike's phase contrast optics
    Takano, Hidekazu
    Wu, Yanlin
    Irwin, Jeff
    Maderych, Stan
    Leibowitz, Marty
    Tkachuk, Andrei
    Kumar, Arjun
    Hornberger, Benjamin
    Momose, Atsushi
    APPLIED PHYSICS LETTERS, 2018, 113 (06)