Synchrotron-based phase contrast imaging of cardiovascular tissue in mice-grating interferometry or phase propagation?

被引:2
|
作者
Trachet, Bram [1 ,2 ]
Lovric, Goran [3 ,4 ]
Villanueva-Perez, Pablo [4 ]
Aslanidou, Lydia [1 ]
Ferraro, Mauro [1 ]
Logghe, Gerlinde [2 ]
Stergiopulos, Nikolaos [1 ]
Segers, Patrick [2 ]
机构
[1] Ecole Polytech Fed Lausanne, Inst Bioengn, Lausanne, Switzerland
[2] Univ Ghent, bioMMeda, Ghent, Belgium
[3] Ecole Polytech Fed Lausanne, Ctr Imagerie BioMed, Lausanne, Switzerland
[4] Paul Scherrer Inst, Swiss Light Source, Villigen, Switzerland
来源
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS | 2019年 / 5卷 / 01期
基金
瑞士国家科学基金会;
关键词
synchrotron-based x-ray imaging; grating interferometry; phase propagation; mouse models of cardiovascular disease; AORTIC-ANEURYSM; TOMOGRAPHY; RESOLUTION; DISEASE; MODEL; ARCH;
D O I
10.1088/2057-1976/aaeb65
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Synchrotron-based x-ray phase-contrast imaging allows for detailed 3D insight into the microstructure of soft tissue and is increasingly used to improve our understanding of mouse models of cardiovascular disease. Two techniques dominate the field: grating interferometry, with superior density contrast at mid to lower microscopic resolutions, and propagation-based phase contrast, facilitating high-resolution tissue imaging. The choice between these techniques depends on which features one is interested in visualizing and is thus highly sample-dependent. In this manuscript we systematically evaluate the advantages and disadvantages of grating interferometry and propagation-based phase contrast for the specific application of pre-clinical cardiovascular tissue. We scanned samples obtained from 5 different mouse models of cardiovascular disease, ranging from carotid plaques over ascending and abdominal aortic aneurysms to hypertrophic hearts. Based on our findings we discuss in detail how synchrotron-based imaging can be used to increase our understanding of the anatomy and biomechanics of cardiovascular disease in mice. We also present a flowchart that can help future users to select the best synchrotron-based phase contrast technique for their pre-clinical cardiovascular samples.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Optimization of propagation-based phase-contrast imaging at a laboratory setup
    Bidola, Pidassa M.
    Zanette, Irene
    Achterhold, Klaus
    Holzner, Christian
    Pfeiffer, Franz
    OPTICS EXPRESS, 2015, 23 (23): : 30000 - 30013
  • [32] Monte Carlo simulation of grating-based neutron phase contrast imaging at CPHS
    Zhang, Ran
    Chen, Zhiqiang
    Huang, Zhifeng
    Xiao, Yongshun
    Wang, Xuewu
    Wie, Jie
    Loong, C. -K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 651 (01) : 12 - 15
  • [33] Preliminary comparison of grating-based and in-line phase contrast X-ray imaging with synchrotron radiation for mouse kidney at TOMCAT
    Sun, J.
    Liu, P.
    Irvine, S.
    Pinzer, B.
    Stampanoni, M.
    Xu, L. X.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [34] Milestones and Basic Principles of Grating-Based X-ray and Neutron Phase-Contrast Imaging
    Pfeiffer, Franz
    INTERNATIONAL WORKSHOP ON X-RAY AND NEUTRON PHASE IMAGING WITH GRATINGS, 2012, 1466 : 2 - 11
  • [35] Propagation-based Phase-Contrast X-ray Imaging at a Compact Light Source
    Gradl, Regine
    Dierolf, Martin
    Hehn, Lorenz
    Guenther, Benedikt
    Yildirim, Ali Oender
    Gleich, Bernhard
    Achterhold, Klaus
    Pfeiffer, Franz
    Morgan, Kaye Susannah
    SCIENTIFIC REPORTS, 2017, 7
  • [36] Factors influencing real time internal structural visualization and dynamic process monitoring in plants using synchrotron-based phase contrast X-ray imaging
    Karunakaran, Chithra
    Lahlali, Rachid
    Zhu, Ning
    Webb, Adam M.
    Schmidt, Marina
    Fransishyn, Kyle
    Belev, George
    Wysokinski, Tomasz
    Olson, Jeremy
    Cooper, David M. L.
    Hallin, Emil
    SCIENTIFIC REPORTS, 2015, 5
  • [37] Propagation-based x-ray phase contrast imaging using an iterative phase diversity technique
    Carroll, Aidan J.
    van Riessen, Grant A.
    Balaur, Eugeniu
    Dolbnya, Igor P.
    Tran, Giang N.
    Peele, Andrew G.
    JOURNAL OF OPTICS, 2018, 20 (03)
  • [38] Method of single exposure phase contrast imaging without analyser grating
    Yao Chun-Xia
    He Qi-Li
    Zhang Jin
    Fu Tian-Yu
    Wu Zhao
    Wang Shan-Feng
    Huang Wan-Xia
    Yuan Qing-Xi
    Liu Peng
    Wang Yan
    Zhang Kai
    ACTA PHYSICA SINICA, 2021, 70 (02)
  • [39] Grating-based X-ray phase-contrast imaging at PETRA III
    Hipp, A.
    Beckmann, F.
    Lytaev, P.
    Greving, I.
    Lottermoser, L.
    Dose, T.
    Kirchhof, R.
    Burmester, H.
    Schreyer, A.
    Herzen, J.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IX, 2014, 9212
  • [40] Simulation and measurement of grating-based X-ray phase-contrast imaging
    Bartl, P.
    Bayer, F.
    Durst, J.
    Haas, W.
    Michel, T.
    Pelzer, G.
    Ritter, A.
    Weber, T.
    Anton, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S269 - S272