Synchrotron-based phase contrast imaging of cardiovascular tissue in mice-grating interferometry or phase propagation?

被引:2
|
作者
Trachet, Bram [1 ,2 ]
Lovric, Goran [3 ,4 ]
Villanueva-Perez, Pablo [4 ]
Aslanidou, Lydia [1 ]
Ferraro, Mauro [1 ]
Logghe, Gerlinde [2 ]
Stergiopulos, Nikolaos [1 ]
Segers, Patrick [2 ]
机构
[1] Ecole Polytech Fed Lausanne, Inst Bioengn, Lausanne, Switzerland
[2] Univ Ghent, bioMMeda, Ghent, Belgium
[3] Ecole Polytech Fed Lausanne, Ctr Imagerie BioMed, Lausanne, Switzerland
[4] Paul Scherrer Inst, Swiss Light Source, Villigen, Switzerland
来源
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS | 2019年 / 5卷 / 01期
基金
瑞士国家科学基金会;
关键词
synchrotron-based x-ray imaging; grating interferometry; phase propagation; mouse models of cardiovascular disease; AORTIC-ANEURYSM; TOMOGRAPHY; RESOLUTION; DISEASE; MODEL; ARCH;
D O I
10.1088/2057-1976/aaeb65
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Synchrotron-based x-ray phase-contrast imaging allows for detailed 3D insight into the microstructure of soft tissue and is increasingly used to improve our understanding of mouse models of cardiovascular disease. Two techniques dominate the field: grating interferometry, with superior density contrast at mid to lower microscopic resolutions, and propagation-based phase contrast, facilitating high-resolution tissue imaging. The choice between these techniques depends on which features one is interested in visualizing and is thus highly sample-dependent. In this manuscript we systematically evaluate the advantages and disadvantages of grating interferometry and propagation-based phase contrast for the specific application of pre-clinical cardiovascular tissue. We scanned samples obtained from 5 different mouse models of cardiovascular disease, ranging from carotid plaques over ascending and abdominal aortic aneurysms to hypertrophic hearts. Based on our findings we discuss in detail how synchrotron-based imaging can be used to increase our understanding of the anatomy and biomechanics of cardiovascular disease in mice. We also present a flowchart that can help future users to select the best synchrotron-based phase contrast technique for their pre-clinical cardiovascular samples.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Comprehensive assessment of myocardial remodeling in ischemic heart disease by synchrotron propagation based X-ray phase contrast imaging
    Planinc, Ivo
    Garcia-Canadilla, Patricia
    Dejea, Hector
    Ilic, Ivana
    Guasch, Eduard
    Zamora, Monica
    Crispi, Fatima
    Stampanoni, Marco
    Milicic, Davor
    Bijnens, Bart
    Bonnin, Anne
    Cikes, Maja
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [22] Quantitative X-ray phase contrast computed tomography with grating interferometry Biomedical applications of quantitative X-ray grating-based phase contrast computed tomography
    Birnbacher, Lorenz
    Braig, Eva-Maria
    Pfeiffer, Daniela
    Pfeiffer, Franz
    Herzen, Julia
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (13) : 4171 - 4188
  • [23] Microvoids in Solids: Synchrotron Radiation Phase Contrast Imaging and Simulations
    Kohn, Victor G.
    Argunova, Tatiana S.
    Je, Jung Ho
    PHYSICA STATUS SOLIDI B-BASIC SOLID STATE PHYSICS, 2018, 255 (09):
  • [24] Experimental optimization of X-ray propagation-based phase contrast imaging geometry
    Dierks, Hanna
    Wallentin, Jesper
    OPTICS EXPRESS, 2020, 28 (20): : 29562 - 29575
  • [25] High sensitivity X-ray phase contrast imaging by laboratory grating-based interferometry at high Talbot order geometry
    Vila-Comamala, Joan
    Romano, Lucia
    Jefimovs, Konstantins
    Dejea, Hector
    Bonnin, Anne
    Cook, Andrew C.
    Planinc, Ivo
    Cikes, Maja
    Wang, Zhentian
    Stampanoni, Marco
    OPTICS EXPRESS, 2021, 29 (02) : 2049 - 2064
  • [26] Phase Contrast Imaging of Cochlear Soft Tissue
    Smith, Stephanie Shintani
    Hwang, Margaret
    Rau, Christoph
    Fishman, Andrew J.
    Lee, Wah-Keat
    Richter, Claus-Peter
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS VII, 2011, 7883
  • [27] High sensitivity phase retrieval method in grating-based x-ray phase contrast imaging
    Wu, Zhao
    Gao, Kun
    Chen, Jian
    Wang, Dajiang
    Wang, Shenghao
    Chen, Heng
    Bao, Yuan
    Shao, Qigang
    Wang, Zhili
    Zhang, Kai
    Zhu, Peiping
    Wu, Ziyu
    MEDICAL PHYSICS, 2015, 42 (02) : 741 - 749
  • [28] Unraveling the biomechanical properties of collagenous tissues pathologies using synchrotron-based phase-contrast microtomography with deep learning
    Furlani, Michele
    Riberti, Nicole
    Di Nicola, Marta
    Giuliani, Alessandra
    FRONTIERS IN PHYSICS, 2023, 11
  • [29] Grating-Based Phase-Contrast Imaging of Tumor Angiogenesis in Lung Metastases
    Lin, Huimin
    Kou, Binquan
    Li, Xiangting
    Wang, Yujie
    Ding, Bei
    Shi, Chen
    Liu, Huanhuan
    Tang, Rongbiao
    Sun, Jianqi
    Yan, Fuhua
    Zhang, Huan
    PLOS ONE, 2015, 10 (03):
  • [30] Noise in x-ray grating-based phase-contrast imaging
    Weber, Thomas
    Bartl, Peter
    Bayer, Florian
    Durst, Juergen
    Haas, Wilhelm
    Michel, Thilo
    Ritter, Andre
    Anton, Gisela
    MEDICAL PHYSICS, 2011, 38 (07) : 4133 - 4140