Synchrotron-based phase contrast imaging of cardiovascular tissue in mice-grating interferometry or phase propagation?

被引:2
|
作者
Trachet, Bram [1 ,2 ]
Lovric, Goran [3 ,4 ]
Villanueva-Perez, Pablo [4 ]
Aslanidou, Lydia [1 ]
Ferraro, Mauro [1 ]
Logghe, Gerlinde [2 ]
Stergiopulos, Nikolaos [1 ]
Segers, Patrick [2 ]
机构
[1] Ecole Polytech Fed Lausanne, Inst Bioengn, Lausanne, Switzerland
[2] Univ Ghent, bioMMeda, Ghent, Belgium
[3] Ecole Polytech Fed Lausanne, Ctr Imagerie BioMed, Lausanne, Switzerland
[4] Paul Scherrer Inst, Swiss Light Source, Villigen, Switzerland
来源
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS | 2019年 / 5卷 / 01期
基金
瑞士国家科学基金会;
关键词
synchrotron-based x-ray imaging; grating interferometry; phase propagation; mouse models of cardiovascular disease; AORTIC-ANEURYSM; TOMOGRAPHY; RESOLUTION; DISEASE; MODEL; ARCH;
D O I
10.1088/2057-1976/aaeb65
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Synchrotron-based x-ray phase-contrast imaging allows for detailed 3D insight into the microstructure of soft tissue and is increasingly used to improve our understanding of mouse models of cardiovascular disease. Two techniques dominate the field: grating interferometry, with superior density contrast at mid to lower microscopic resolutions, and propagation-based phase contrast, facilitating high-resolution tissue imaging. The choice between these techniques depends on which features one is interested in visualizing and is thus highly sample-dependent. In this manuscript we systematically evaluate the advantages and disadvantages of grating interferometry and propagation-based phase contrast for the specific application of pre-clinical cardiovascular tissue. We scanned samples obtained from 5 different mouse models of cardiovascular disease, ranging from carotid plaques over ascending and abdominal aortic aneurysms to hypertrophic hearts. Based on our findings we discuss in detail how synchrotron-based imaging can be used to increase our understanding of the anatomy and biomechanics of cardiovascular disease in mice. We also present a flowchart that can help future users to select the best synchrotron-based phase contrast technique for their pre-clinical cardiovascular samples.
引用
收藏
页数:11
相关论文
共 50 条
  • [11] Advanced phase-contrast imaging using a grating interferometer
    McDonald, Samuel Alan
    Marone, Federica
    Hintermueller, Christoph
    Mikuljan, Gordan
    David, Christian
    Pfeiffer, Franz
    Stampanoni, Marco
    JOURNAL OF SYNCHROTRON RADIATION, 2009, 16 : 562 - 572
  • [12] Grating-based X-ray phase contrast for biomedical imaging applications
    Pfeiffer, Franz
    Herzen, Julia
    Wiliner, Marian
    Chabior, Michael
    Auweter, Sigrid
    Reiser, Maximilian
    Bamberg, Fabian
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2013, 23 (03): : 176 - 185
  • [13] Contrast enhancement of propagation based X-ray phase contrast imaging
    Pan, Adam
    Xu, Ling
    Petruccelli, Jon C.
    Gupta, Rajiv
    Barbastathis, George
    ADVANCES IN COMPUTATIONAL METHODS FOR X-RAY OPTICS III, 2014, 9209
  • [14] Dual phase grating based X-ray differential phase contrast imaging with source grating: theory and validation
    Ge, Yongshuai
    Chen, Jianwei
    Zhu, Peiping
    Yang, Jun
    Deng, Shiwo
    Shi, Wei
    Zhang, Kai
    Guo, Jinchuan
    Zhang, Huitao
    Zheng, Hairong
    Liang, Dong
    OPTICS EXPRESS, 2020, 28 (07) : 9786 - 9801
  • [15] Phase contrast portal imaging using synchrotron radiation
    Umetani, K.
    Kondoh, T.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (07)
  • [16] Propagation-based phase-contrast synchrotron imaging of aortic dissection in mice: from individual elastic lamella to 3D analysis
    Logghe, Gerlinde
    Trachet, Bram
    Aslanidou, Lydia
    Villaneuva-Perez, Pablo
    De Backer, Julie
    Stergiopulos, Nikolaos
    Stampanoni, Marco
    Aoki, Hiroki
    Segers, Patrick
    SCIENTIFIC REPORTS, 2018, 8
  • [17] Phase contrast laminography based on Talbot interferometry
    Altapova, Venera
    Helfen, Lukas
    Myagotin, Anton
    Haenschke, Daniel
    Moosmann, Julian
    Gunneweg, Jan
    Baumbach, Tilo
    OPTICS EXPRESS, 2012, 20 (06): : 6496 - 6508
  • [18] A uniqueness result for propagation-based phase contrast imaging from a single measurement
    Maretzke, Simon
    INVERSE PROBLEMS, 2015, 31 (06)
  • [19] X-ray phase contrast simulation for grating-based interferometry using GATE
    Sanctorum, Jonathan
    De Beenhouwer, Jan
    Sijbers, Jan
    OPTICS EXPRESS, 2020, 28 (22) : 33390 - 33412
  • [20] Comparison of propagation-based phase-contrast CT and absorption-based CT for breast imaging using synchrotron radiation
    Taba, Seyedamir Tavakoli
    Lewis, Sarah
    Baran, Patrycja M.
    Arhatari, Benedicta D.
    Nesterets, Yakov, I
    Mayo, Sherry C.
    Thompson, Darren
    Fox, Jane
    Kumar, Beena
    Prodanovic, Zdenka
    Hausermann, Daniel
    Maksimenko, Anton
    Hall, Chris
    Dimmock, Matthew
    Pavlov, Konstantin M.
    Peele, Andrew
    Quiney, Harry M.
    Lockie, Darren
    Tromba, Giuliana
    Gureyev, Timur E.
    Brennan, Patrick C.