Synchrotron-based phase contrast imaging of cardiovascular tissue in mice-grating interferometry or phase propagation?

被引:2
|
作者
Trachet, Bram [1 ,2 ]
Lovric, Goran [3 ,4 ]
Villanueva-Perez, Pablo [4 ]
Aslanidou, Lydia [1 ]
Ferraro, Mauro [1 ]
Logghe, Gerlinde [2 ]
Stergiopulos, Nikolaos [1 ]
Segers, Patrick [2 ]
机构
[1] Ecole Polytech Fed Lausanne, Inst Bioengn, Lausanne, Switzerland
[2] Univ Ghent, bioMMeda, Ghent, Belgium
[3] Ecole Polytech Fed Lausanne, Ctr Imagerie BioMed, Lausanne, Switzerland
[4] Paul Scherrer Inst, Swiss Light Source, Villigen, Switzerland
来源
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS | 2019年 / 5卷 / 01期
基金
瑞士国家科学基金会;
关键词
synchrotron-based x-ray imaging; grating interferometry; phase propagation; mouse models of cardiovascular disease; AORTIC-ANEURYSM; TOMOGRAPHY; RESOLUTION; DISEASE; MODEL; ARCH;
D O I
10.1088/2057-1976/aaeb65
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Synchrotron-based x-ray phase-contrast imaging allows for detailed 3D insight into the microstructure of soft tissue and is increasingly used to improve our understanding of mouse models of cardiovascular disease. Two techniques dominate the field: grating interferometry, with superior density contrast at mid to lower microscopic resolutions, and propagation-based phase contrast, facilitating high-resolution tissue imaging. The choice between these techniques depends on which features one is interested in visualizing and is thus highly sample-dependent. In this manuscript we systematically evaluate the advantages and disadvantages of grating interferometry and propagation-based phase contrast for the specific application of pre-clinical cardiovascular tissue. We scanned samples obtained from 5 different mouse models of cardiovascular disease, ranging from carotid plaques over ascending and abdominal aortic aneurysms to hypertrophic hearts. Based on our findings we discuss in detail how synchrotron-based imaging can be used to increase our understanding of the anatomy and biomechanics of cardiovascular disease in mice. We also present a flowchart that can help future users to select the best synchrotron-based phase contrast technique for their pre-clinical cardiovascular samples.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Technical Note: Single-shot phase retrieval method for synchrotron-based high-energy x-ray grating interferometry
    Wang, Zhili
    Ren, Kun
    Shi, Xiaomin
    Liu, Dalin
    Wu, Zhao
    Gao, Kun
    MEDICAL PHYSICS, 2019, 46 (03) : 1317 - 1322
  • [2] Theoretical comparison of three X-ray phase-contrast imaging techniques: propagation-based imaging, analyzer-based imaging and grating interferometry
    Diemoz, P. C.
    Bravin, A.
    Coan, P.
    OPTICS EXPRESS, 2012, 20 (03): : 2789 - 2805
  • [3] Feasibility and safety of synchrotron-based X-ray phase contrast imaging as a technique complementary to histopathology analysis
    Li, Kan Yan Chloe
    Dejea, Hector
    De Winne, Koen
    Bonnin, Anne
    D'Onofrio, Valentino
    Cox, Janneke A.
    Garcia-Canadilla, Patricia
    Lammens, Martin
    Cook, Andrew C.
    Bijnens, Bart
    Dendooven, Amelie
    HISTOCHEMISTRY AND CELL BIOLOGY, 2023, 160 (05) : 377 - 389
  • [4] In-line phase-contrast and grating-based phase-contrast synchrotron imaging study of brain micrometastasis of breast cancer
    Huang, Sheng
    Kou, Binquan
    Chi, Yayun
    Xi, Yan
    Cao, Yixin
    Cui, Wenli
    Hu, Xin
    Shao, Zhimin
    Guo, Han
    Fu, Yanan
    Xiao, Tiqiao
    Sun, Jianqi
    Zhao, Jun
    Wang, Yujie
    Wu, Jiong
    SCIENTIFIC REPORTS, 2015, 5
  • [5] Contrast transfer function in grating-based x-ray phase-contrast imaging
    Huang, Jianheng
    Du, Yang
    Lin, Danying
    Liu, Xin
    Niu, Hanben
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 747 : 13 - 18
  • [6] Imaging brain amyloid deposition using grating-based differential phase contrast tomography
    Pinzer, B. R.
    Cacquevel, M.
    Modregger, P.
    McDonald, S. A.
    Bensadoun, J. C.
    Thuering, T.
    Aebischer, P.
    Stampanoni, M.
    NEUROIMAGE, 2012, 61 (04) : 1336 - 1346
  • [7] Deciphering complex, functional structures with synchrotron-based absorption and phase contrast tomographic microscopy
    Stampanoni, M.
    Reichold, J.
    Weber, B.
    Haberthuer, D.
    Schittny, J.
    Eller, J.
    Buechi, F. N.
    Marone, F.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VII, 2010, 7804
  • [8] Grating interferometry-based phase microtomography of atherosclerotic human arteries
    Buscema, Marzia
    Holme, Margaret N.
    Deyhle, Hans
    Schulz, Georg
    Schmitz, Ruediger
    Thalmann, Peter
    Hieber, Simone E.
    Chicherova, Natalia
    Cattin, Philippe C.
    Beckmann, Felix
    Herzen, Julia
    Weitkamp, Timm
    Saxer, Till
    Mueller, Bert
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IX, 2014, 9212
  • [9] Simulation of X-ray Phase-contrast Imaging Using Grating-interferometry
    Bartl, P.
    Durst, J.
    Haas, W.
    Michel, T.
    Ritter, A.
    Weber, T.
    Anton, G.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3577 - 3580
  • [10] Feasibility study of propagation-based phase-contrast X-ray lung imaging on the Imaging and Medical beamline at the Australian Synchrotron
    Murrie, Rhiannon P.
    Stevenson, Andrew W.
    Morgan, Kaye S.
    Fouras, Andreas
    Paganin, David M.
    Siu, Karen K. W.
    JOURNAL OF SYNCHROTRON RADIATION, 2014, 21 : 430 - 445