Solid desiccant air-conditioning systems - Design parameters

被引:67
作者
Panaras, G. [1 ]
Mathioulakis, E. [1 ]
Belessiotis, V. [1 ]
机构
[1] NCSR Demokritos, Solar & Other Energy Syst Lab, Aghia Paraskevi 15310, Greece
关键词
Solid desiccant cooling; Solar air-conditioning; Desiccant systems design parameters; PERFORMANCE; ENERGY;
D O I
10.1016/j.energy.2011.01.022
中图分类号
O414.1 [热力学];
学科分类号
摘要
Solid desiccant air-conditioning systems can take care of both the sensible and latent load of a conditioned space, as well as of the fresh air requirements, through the use of thermal energy. The development of desiccant systems, competitive to conventional cooling ones, would require the optimization of the parameters which are involved in the design of the systems for a range of ambient conditions the systems will face throughout their lifetime. The present work aims at identifying the main design parameters, and investigates their effect on the performance of the systems. Specific guidelines for the dimensioning of the systems are proposed, on the basis of an easy to implement steady state model. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2399 / 2406
页数:8
相关论文
共 40 条
[1]  
*AM GAS COOL CTR, 1999, APPL ENG MAN DES SYS
[2]  
[Anonymous], 2004, 552004 ANSIASHRAE
[3]  
*ASHRAE, 1998, PRINC HEAT VENT AIR
[4]  
*ASHRAE, 2001, HDB 2001 FUND
[5]  
BALARAS CA, 2006, TYPICAL METEOROLOGIC
[6]   Solar air conditioning in Europe - an overview [J].
Balaras, Constantinos A. ;
Grossman, Gershon ;
Henning, Hans-Martin ;
Infante Ferreira, Carlos A. ;
Podesser, Erich ;
Wang, Lei ;
Wiemken, Edo .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2007, 11 (02) :299-314
[7]   Comparison between the conventional and recirculation modes in desiccant cooling cycles and deriving critical efficiencies of components [J].
Bourdoukan, P. ;
Wurtz, E. ;
Joubert, P. .
ENERGY, 2010, 35 (02) :1057-1067
[8]   Experimental investigation of a solar desiccant cooling installation [J].
Bourdoukan, P. ;
Wurtz, E. ;
Joubert, P. .
SOLAR ENERGY, 2009, 83 (11) :2059-2073
[9]   Experimental performance of a direct evaporative cooler operating during summer in a Brazilian city [J].
Camargo, JR ;
Ebinuma, CD ;
Silveira, JL .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (07) :1124-1132
[10]   A methodology for the performance evaluation of an experimental desiccant cooling system [J].
Çarpinlioglu, MO ;
Yildirim, M .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2005, 32 (10) :1400-1410