State Estimation Error Detection System for Online Dynamic Security Assessment

被引:0
作者
Tsujii, Yuki [1 ]
Kawakita, Ken Edward [1 ]
Kumagai, Masatoshi [1 ]
Kikuchi, Akira [1 ]
Watanabe, Masahiro [1 ]
机构
[1] Hitachi Ltd, Res & Dev Grp, Hitachi, Ibaraki, Japan
来源
2017 IEEE POWER & ENERGY SOCIETY INNOVATIVE SMART GRID TECHNOLOGIES CONFERENCE (ISGT) | 2017年
关键词
Power System; Dynamic Security Assessment; State Estimation; Transient Stability; Phasor Measurements Units; PHASOR MEASUREMENTS;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Online Dynamic Security Assessment (DSA) is a dynamical system widely used for assessing and analyzing an electrical power system. The outcomes of DSA arc used in many aspects of the operation of power system, from monitoring the system to determining remedial action schemes (e.g. the amount of generators to be shed at the event of a fault). Measurement from supervisory control and data acquisition (SCADA) and state estimation (SE) results arc the inputs for online-DSA, however, the SE error, caused by sudden change in power flow or low convergence rate, could be unnoticed and skew the outcome. Therefore, generator shedding scheme cannot achieve optimum but must have some margin because we don't know how SE error caused by these problems will impact power system stability control. As a method for solving the problem, we developed SE error detection system (EDS), which is enabled by detecting the SE error that will impact power system transient stability. The method is comparing a threshold value and an index calculated by the difference between SE results and PMU observation data, using the distance from the fault point and the power flow value. Using the index, the reliability of the SE results can be verified. As a result, online-DSA can use the SE results while avoiding the bad SE results, assuring the outcome of the DSA assessment and analysis, such as the amount of generator shedding in order to prevent the power system's instability.
引用
收藏
页数:5
相关论文
共 14 条
[1]  
Abur A., 2004, POWER SYSTEM STATE E
[2]  
Baltensperger R., P 2010 IET INT C DEV
[3]   A novel hybrid state estimator for including synchronized phasor measurements [J].
Bi, T. S. ;
Qin, X. H. ;
Yang, Q. X. .
ELECTRIC POWER SYSTEMS RESEARCH, 2008, 78 (08) :1343-1352
[4]   Inclusion of PMU current phasor measurements in a power system state estimator [J].
Chakrabarti, S. ;
Kyriakides, E. ;
Ledwich, G. ;
Ghosh, A. .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2010, 4 (10) :1104-1115
[5]  
Chakrabarti S., 2010, P IEEE POW EN SOC GE
[6]  
Manousakis N.M., 2013, POWERTECH
[7]  
Nuqui R. F., P 2007 POWERTECH LAU, P1665
[8]  
Phadke A. G., 2009, POW SYST C EXP MAR
[9]  
Vide P. C., 2012, ELEKTRO
[10]   Transient security assessment in real-time at southern company [J].
Viikinsalo, James ;
Martin, Alan ;
Morison, Kip ;
Wang, Lei ;
Howell, Frederic .
2006 IEEE/PES POWER SYSTEMS CONFERENCE AND EXPOSITION. VOLS 1-5, 2006, :13-+